Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point.Aims
Methods
Abstract. Introduction. Patients presenting with loosening or a fracture between ipsilateral hip and knee replacements provide a unique reconstructive challenge. We present mid-term results of the cement-over megaprosthesis (COM) when managing these complex cases. A COM is cement-linked to the stem of a well-fixed existing implant. We report the largest series to date and show that this may be preferable to total femoral replacement in a cohort of patients who often have significant co-morbidities. Methodology. A retrospective analysis of patients undergoing COM between 2002–2022 was performed. Primary outcomes were defined as implant survival, displayed with survival analysis. Secondary outcomes included mortality and surgical complications. Functional outcomes included Visual Analogue Score (VAS), EuroQol-5D-3L and Musculoskeletal Tumour Society (MSTS) score at one year post operatively. Results. 34 patients underwent reconstructive cement-over technique. There were 20 custom distal femur replacements and 10 custom proximal femoral replacements. Two patients were revised, with a
The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model.Aims
Methods
Pelvic discontinuity is a separation through the acetabulum with the ilium displacing superiorly and the ischium/pubis displacing inferiorly. This is a biomechanically challenging environment with a high rate of failure for standard acetabular components. The cup-cage reconstruction involves the use of a highly porous metal cup to achieve biological bone ingrowth on both sides of the pelvic discontinuity and an ilioischial cage to provide secure fixation across the discontinuity and bring the articulating hip center to the correct level. The purpose of this study was to report long term follow up of the use of the cup-cage to treat pelvic discontinuity. All hip revision procedures between January 2003 and January 2022 where a cup-cage was used for a hip with a pelvic discontinuity were included in this retrospective review. All patients received a Trabecular Metal Revision Shell with either a ZCA cage or TMARS cage (Zimmer-Biomet Inc.). Pelvic discontinuity was diagnosed on pre-operative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed with failure defined as revision of the cup-cage reconstruction. Fifty-seven cup-cages in 56 patients were included with an average follow-up of 6.25 years (0.10 to 19.98 years). The average age of patients was 72.09 years (43 to 92 years) and 70.2% of patients were female. The five year Kaplan-Meier survival was 92.0% (95% CI 84.55 to 99.45) and the
The aim of this study was to compare ten-year longitudinal healthcare costs and revision rates for patients undergoing unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The Humana database was used to compare 2,383 patients undergoing UKA between 2007 and 2009, who were matched 1:1 from a cohort of 63,036 patients undergoing primary TKA based on age, sex, and Elixhauser Comorbidity Index. Medical and surgical complications were tracked longitudinally for one year following surgery. Rates of revision surgery and cumulative mean healthcare costs were recorded for this period of time and compared between the cohorts.Aims
Methods
The Exeter V40 cemented femoral stem was first introduced in 2000. The largest single-centre analysis of this implant to date was published in 2018 by Westerman et al. Excellent results were reported at a minimum of ten years for the first 540 cases performed at the designer centre in the Exeter NHS Trust, with stem survivorship of 96.8%. The aim of this current study is to report long-term outcomes and survivorship for the Exeter V40 stem in a non-designer centre. All patients undergoing primary total hip arthroplasty using the Exeter V40 femoral stem between 1 January 2005 and 31 January 2010 were eligible for inclusion. Data were collected prospectively, with routine follow-up at six to 12 months, two years, five years, and ten years. Functional outcomes were assessed using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. Outcome measures included data on all components in situ beyond ten years, death occurring within ten years with components in situ, and all-cause revision surgery.Aims
Methods
The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs). A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively.Aims
Methods
The purpose of this study is to examine six types of bearing surfaces implanted at a single institution over three decades to determine whether the reasons for revision vary among the groups and how long it takes to identify differences in survival. We considered six cohorts that included a total of 1,707 primary hips done between 1982 and 2010. These included 223 conventional polyethylene sterilized with γ irradiation in air (CPE-GA), 114 conventional polyethylene sterilized with gas plasma (CPE-GP), 116 crosslinked polyethylene (XLPE), 1,083 metal-on-metal (MOM), 90 ceramic-on-ceramic (COC), and 81 surface arthroplasties (SAs). With the exception of the COC, all other groups used cobalt-chromium (CoCr) femoral heads. The mean follow-up was 10 (0.008 to 35) years. Descriptive statistics with revisions per 100 component years (re/100 yr) and survival analysis with revision for any reason as the endpoint were used to compare bearing surfaces.Aims
Methods
Aim. This study quantified changes in the microbiology of osteomyelitis in a single specialist centre within the UK. The rate of infection with multi-drug-resistant (MDR) bacteria was measured over a
Highly porous tantalum cups have been used in complex acetabular revisions for nearly 20 years but reports of long term results are limited. This study was designed to report
Assess union rate, complications, and outcomes of large series of contemporary extended trochanteric osteotomies (ETOs) performed during revision THAs. From 2003 to 2013, 612 ETOs were performed during revision THAs using 2 techniques. 367 were Paprosky type and 245 were Wagner type. Indications were aseptic loosening (65%), periprosthetic joint infection (18%), periprosthetic fracture (6%), femoral implant fracture (5%), and other (6%). Mean age 69 years, 58% male. Median follow-up 5 years (range, 2.1 to 13 years). Mean Harris Hip Scores increased from 57 preoperatively to 77 at latest follow-up (p=0.0001). Radiographic union of the extended osteotomy occurred in 98%. There were 9 ETO nonunions. Mean time to union of the distal transverse osteotomy was 5.9 months (range, 1 month − 2 years). Mean trochanteric osteotomy fragment migration prior to union was 3 mm (range, 0–29 mm). Over 1 cm of migration occurred in 7.4%. Intraoperative fracture of the ETO diaphyseal fragment occurred in 4%, and postoperative greater trochanter fractures in 8.8%. Other complications: dislocation in 5.7% and infection in 3.4%. Dislocation occurred in 19 of 462 with ETO migration < 1 cm and 4 of 39 with ETO migration ≥1 cm (p=0.08).
Introduction. Open hip debridement surgery has been used for treatment of femoral acetabular impingement pain for over ten years in our unit. While literature has reported promising short-term outcomes, longer term outcomes are more sparsely reported. Patients/Materials & Methods. Patients who had undergone this surgery were identified on our database. Electronic, radiographic and paper records were reviewed. Demographic data, radiological and operative findings were recorded. Patients underwent ten-year review with standardised AP hip radiographs, questionnaire, non-arthritic hip (NAHS), Oxford hip (OHS) and SF-12 scores. Results. A total of 1626 operations were identified of which 183 had reached the tenth anniversary of their surgery. There were 91 females and 92 males. The average age was 39. Kaplan-Meier analysis indicated an overall 78% survival at ten years. However, once the learning curve was accounted for, by excluding the first year's cohort of patients, the survival rate was 84% at 10 years. Those who underwent hip arthroplasty were older at initial surgery and had a higher Tonnis grade than those who survived. The majority failed within the first 2 years. Labral repair, restoration of a normal centre edge angle and adequate CAM correction were associated with better survival. In those whose hip survived, the average NAHS and OHS were 87 and 39 respectively. 15% required further non-arthroplasty surgery (scope/revision) and 51% underwent trochanteric screw removal. 89% of survivors deemed their surgery to have been worthwhile at
Dislocation rates are reportedly lower in patients requiring
proximal femoral hemiarthroplasty than for patients undergoing hip
arthroplasty for neoplasia. Without acetabular replacement, pain
due to acetabular wear necessitating revision surgery has been described.
We aimed to determine whether wear of the native acetabulum following
hemiarthroplasty necessitates revision surgery with secondary replacement
of the acetabulum after proximal femoral replacement (PFR) for tumour
reconstruction. We reviewed 100 consecutive PFRs performed between January 2003
and January 2013 without acetabular resurfacing. The procedure was
undertaken in 74 patients with metastases, for a primary bone tumour
in 20 and for myeloma in six. There were 48 male and 52 female patients,
with a mean age of 61.4 years (19 to 85) and median follow-up of
two years (interquartile range (IQR) 0.5 to 3.7 years). In total,
52 patients presented with a pathological fracture and six presented
with failed fixation of a previously instrumented pathological fracture.Aims
Patients and Methods
There has been a significant decline in the use of metal-on-metal (MoM) bearings due to concerns regarding adverse reaction to metal debris (ARMD). The Medicines and Healthcare products Regulatory Agency (MHRA) recommends annual follow-up for life with blood Cobalt (Co) and Chromium (Cr) ion level measurement in all MoM THRs with femoral head size greater than or equal to 36mm. We present the serial
It is not clear whether anterior knee pain and osteoarthritis
(OA) of the patellofemoral joint (PFJ) are contraindications to
medial unicompartmental knee arthroplasty (UKA). Our aim was to
investigate the long-term outcome of a consecutive series of patients,
some of whom had anterior knee pain and PFJ OA managed with UKA. We assessed the ten-year functional outcomes and 15-year implant
survival of 805 knees (677 patients) following medial mobile-bearing
UKA. The intra-operative status of the PFJ was documented and, with
the exception of bone loss with grooving to the lateral side, neither
the clinical or radiological state of the PFJ nor the presence of
anterior knee pain were considered a contraindication. The impact
of radiographic findings and anterior knee pain was studied in a
subgroup of 100 knees (91 patients).Aims
Patients and Methods
It may not be possible to undertake revision total hip arthroplasty
(THA) in the presence of massive loss of acetabular bone stock using
standard cementless hemispherical acetabular components and metal
augments, as satisfactory stability cannot always be achieved. We
aimed to study the outcome using a reconstruction cage and a porous
metal augment in these patients. A total of 22 acetabular revisions in 19 patients were performed
using a combination of a reconstruction cage and porous metal augments.
The augments were used in place of structural allografts. The mean
age of the patients at the time of surgery was 70 years (27 to 85)
and the mean follow-up was 39 months (27 to 58). The mean number
of previous THAs was 1.9 (1 to 3). All patients had segmental defects
involving more than 50% of the acetabulum and seven hips had an
associated pelvic discontinuity. Aims
Patients and Methods
Unicompartmental knee arthroplasty (UKA) has a long history that extends back nearly as far as the first tricompartmental designs. While initial results were erratic, with a greater understanding of patient selection and surgical techniques, more consistent and favorable results have been reported. While there has been somewhat of a resurgence in interest in UKA, the percentage of primary knee arthroplasties that are unicompartmental hovers around 6–8%. It is my belief that you should be doing more!. Several peer review studies suggest that with both fixed and mobile bearing designs, survivorship exceeds 90% at