Advertisement for orthosearch.org.uk
Results 1 - 20 of 89
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 31 - 31
23 Feb 2023
Hong N Jones C Hong T
Full Access

Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures are a rare and complex injury. Although some advocate non-operative management, grossly displaced glenoid fossa fractures in the young patient may warrant fixation. Current approaches still describe difficulty with access of the entirety of the glenoid, particularly the postero-superior quadrant. We present 2 cases of Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures treated with fixation through a novel “Deltoid Takedown” approach, which allows safe access to the whole glenoid with satisfactory clinical results at 5 and 7 years respectively


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 10 - 10
1 Oct 2015
Prasad KSRK Dayanandam B Clewer G Kumar RK Williams L Karras K
Full Access

Background. Current literature of definition, classification and outcomes of fractures of talar body remains controversial. Our primary purpose is to present an unusual combination of fractures of talar body with pantalar involvement / dislocation / extension as a basis for modification of Müller AO / OTA Classification. Methods. We include four consecutive patients, who sustained talar body fractures with pantalar subluxation/dislocation /extension. These unusual injury patterns lead us to reconsider Müller AO / OTA Classification in the light of another widely used talar fracture classification, Hawkins Classification of fractures of neck of talus and subsequent modification by Canale and Kelly. Results. Müller AO / OTA Classification comprises CI – Ankle joint involvement, C2 – Subtalar joint involvement, C3 – Ankle and subtalar joint involvement. We propose Modification of Müller AO / OTA. Classification. C1 – Absolutely undisplaced fracture; C2 – Ankle and Subtalar joint involvement: subluxation; C3 – Ankle and subtalar joint involvement: subluxation with comminution; C4 – Ankle, subtalar and talonavicular joint involvement. Conclusions. Our modification redefines Müller AO / OTA Classification, extends and fills the void in the classification by inclusion of C4, draws attention to stability of talonavicular joint and reflects increasing severity of injury in fractures of talar body


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 131 - 131
1 Feb 2012
White T Guy P Kennedy S Droll K Blachut P O'Brien P
Full Access

Background. The optimal treatment for pilon fractures remains controversial. We have used early single-stage open reduction and internal fixation to treat these injuries and the purpose of this study was to determine the safety and efficacy of this strategy. Methods. A cohort of 95 patients with AO type C tibial pilon fractures underwent primary ORIF. Of these patients, 21 had open fractures. Sixty-eight fractures were sustained in falls, 21 in motor vehicle collision, 5 in crushes and one in an aircraft crash. The principal outcome measure was wound dehiscence or infection requiring surgery. Radiological and functional outcomes were assessed at a mean of five years using the SF36 and the Foot and Ankle Outcome Score. Results. Primary ORIF was performed within 48 hours of admission in 98% cases. Reduction was anatomical in 90% cases. Six (6%) patients developed a wound infection or dehiscence that required surgical débridement, giving a wound complication rate of 4/21 (19%) for open fractures and 2/74 (2.7%) for closed fractures. Of the two closed fractures, one occurred in a patient with local scarring from previous trauma, insulin-dependent diabetes mellitus and chronic alcohol abuse, and the other in a patient with schizophrenia, diabetes and peripheral neuropathy. Radiographic follow-up revealed 74% patients had normal appearances or mild osteoarthritic degeneration only. Functional outcomes revealed a reduced level of general health and mild disability. Conclusions. Provided surgery is performed expeditiously by experienced orthopaedic trauma surgeons, AO type C pilon fractures can be stabilised safely and effectively by primary ORIF, with very low rates of wound complications, a high quality of reduction, and a good long term outcome. These results compare favourably with the published results for all other methods of treatment


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 95 - 95
1 Mar 2012
Sahu A Harshavardena N Maret S Dhir A Taylor H
Full Access

Introduction. The aim of the study was to analyze the outcome of AO cannulated screws for fractures neck of femur at our institute. Methods. 412 patients (101 males/311 females) who underwent AO screws for fracture neck of femur over 5 years (2000 -2004) and followed-up for a minimum of 2 yrs formed the study population. A retrospective review of data from electronic patient record (EPR), clinical coding, clinic and GP letters was made. Age, residential placement, Garden's classification, mode of injury, associated comorbidities, pre-admission mobilisation status, allergies, addictions and anticoagulation status details were collected. Reasons for re-admissions, re-operations and comorbidities developing as a result of these interventions were critically analysed. Post-op physiotherapy, proportion of patients sustaining contra-lateral fracture NOF and its management and mortality statistics were reviewed. Results. The mean age of patients was 68 yrs (range 18-96 yrs). Mean length of stay in hospital was 12.3 days (range2- 51 days) and mean time to operate from admission was 51 hrs (median 24 hrs). Second Surgery in form of hemiarthroplasty was required in 36, DHS in 7, Implant removal in 15 and Total hip replacement in 29 patients. Non-union occurred in 25 pts (7.93%)and avascular necrosis (AVN) in 61 Pts (19.36%) and overall 2 years mortality rate was 66 pts(16%). Conclusion. AVN and Non union was high in patients with displaced fractures, patients more than 80 yrs and patients with co-morbidities like Renal Failure, Diabetes Mellitus, Osteoporosis and Steroid intake etc. Outcome is influenced by complex interplay of multiple factors so we should treat the physiological age and not the chronological age


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 116 - 116
1 Sep 2012
Barton T Chesser T Harries W Gleeson R Topliss C Greenwood R
Full Access

Controversy exists whether to treat unstable pertrochanteric hip fractures with either intra-medullary or extra-medullary devices. A prospective randomised control trial was performed to compare the outcome of unstable pertrochanteric hip fractures stabilised with either a sliding hip screw or long Gamma Nail. The hypothesis was that there is no difference in outcome between the two modes of treatment.

Over a four year period, 210 patients presenting with an unstable pertrochanteric hip fracture (AO/OTA 31 A2) were recruited into the study. Eligible patients were randomised on admission to either long Gamma Nail or sliding hip screw. Follow-up was arranged for three, six, and twelve months. Primary outcome measures were implant failure or ‘cut-out’. Secondary measures included mortality, length of hospital stay, transfusion rate, change in mobility and residence, and EuroQol outcome score.

Five patients required revision surgery for implant cut-out (2.5%), of which three were long Gamma Nails and two were sliding hip screws (no significant difference). There were no incidences of implant failure or deep infection. Tip apex distance was found to correlate with implant cut-out. There was no statistically significant difference in either the EuroQol outcome scores or mortality rates between the two groups when corrected for mini mental score. There was no difference in transfusion rates, length of hospital stay, and change in mobility or residence. There was a clear cost difference between the implants.

The sliding hip screw remains the gold standard in the treatment of unstable pertrochanteric fractures of the proximal femur.


Long femoral nails for neck of femur fractures and prophylactic fixation have a risk of anterior cortex perforation. Previous studies have demonstrated the radius of curvature (ROC) of a femoral nail influencing the finishing point of a nail and the risk of anterior cortex perforation. This study aims to calculate a patients femoral ROC using preoperative XR and CT and therefore nail finishing position. We conducted a retrospective study review of patients with long femoral cephalomedullary nailing for proximal femur fractures (OTA/AO 31(A) and OTA/AO 32) or impending pathological fractures at a level 1 trauma centre between January 1, 2015 and December 31, 2020 with both full length lateral X-ray and CT imaging. Femoral ROC was calculated on both imaging modalities. Outcomes measured including nail finishing position, anterior cortex encroachment and impingement. The mean femoral ROC was 1026mm on CT and 1244mm on XR. CT femoral ROC strongly correlated with nail finishing point with a spearmans coefficient of 0.77. Additionally, femurs with a ROC <1000mm were associated with a higher risk of anterior encroachment (OR 6.12) and femurs with a ROC <900mm were associated with a higher risk of anterior cortex impingement (OR 6.47). To our knowledge this is the first study to compare a measured femoral ROC to nail finishing position. The use of CT to measure femoral ROC and to a lesser extent XR was able to predict both nail finishing position and risk of anterior cortex encroachment. Preoperative XRs and CTs were able to identify patients with a small femoral ROC. This predicted patients at risk of anterior cortex impingement, anterior cortex encroachment and nail finishing position. We may be able to select femoral nails that resemble the native femoral ROC and mitigate the risk of anterior cortex perforation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 18 - 18
12 Dec 2024
Rai A Nanda R Ponugoti N Saunders M
Full Access

Objectives. Distal humerus fractures in elderly population are often comminuted and presents multiple challenges. When managed with fixation the results are often complicated with stiffness, pain, and reduced function while total elbow replacement is fraught with lifelong restrictions on load bearing which can significantly affect elderly patients who rely assistive devices for ambulation. Elbow hemiarthroplasty however, presents a viable alternative in these cases. This series evaluates the results of the distal humerus hemiarthroplasty in a single centre. Designs and methods. Data was collected retrospectively. Comprehensive case reviews were done to collect demographic, intra-operative and post-operative data. Fractures were classified as per AO classification. The primary outcome was functional outcome and range of motion (ROM). The secondary outcomes were complications and patient satisfaction. Results. 22 cases were included in this study from 2016 – 2023 majority being females (n=18). Mean age was 74years (SD −11.2). Majority fractures were AO type C3 (n=15) with two A2 type fractures managed for non-union. Pre-existing bone on bone arthritis was present in 3 cases and CT scan was done for 12 patients to assess fracture configuration. Excluding those treated for non- union the median time between fracture and surgery was 8.5 days. Follow-up of more than 6 months was available for 16 patients with median follow-up of 18 months. ROM was available for 17 patients with 13 (50%) patients having functional ROM. No patients had full extension and there was a mean lag of 20. 0. Mean flexion was 118.2. 0. Nearly 2/3. rd. patients (73%- n=16) were satisfied with the surgery with no problems in activity of daily living. Complications seen were ulnar neuropathy (n=3), heterotopic ossification(n=2) and periprosthetic fracture (n=1). Conclusion. This single centre study suggests good outcomes following distal humerus hemiarthroplasty. It is a reasonable alternative to fixation and total elbow arthroplasty in complex fractures


Bone & Joint Open
Vol. 5, Issue 9 | Pages 721 - 728
1 Sep 2024
Wetzel K Clauss M Joeris A Kates S Morgenstern M

Aims. It is well described that patients with bone and joint infections (BJIs) commonly experience significant functional impairment and disability. Published literature is lacking on the impact of BJIs on mental health. Therefore, the aim of this study was to assess health-related quality of life (HRQoL) and the impact on mental health in patients with BJIs. Methods. The AO Trauma Infection Registry is a prospective multinational registry. In total, 229 adult patients with long-bone BJI were enrolled between 1 November 2012 and 31 August 2017 in 18 centres from ten countries. Clinical outcome data, demographic data, and details on infections and treatments were collected. Patient-reported outcomes using the 36-Item Short-Form Health Survey questionnaire (SF-36), Parker Mobility Score, and Katz Index of Independence in Activities of Daily Living were assessed at one, six, and 12 months. The SF-36 mental component subscales were analyzed and correlated with infection characteristics and clinical outcome. Results. The SF-36 physical component summary mean at baseline was 30.9 (95% CI 29.7 to 32.0). At one month, it was unchanged (30.5; 95% CI 29.5 to 31.5; p = 0.447); it had improved statistically significantly at six months (35.5; 95% CI 34.2 to 36.7; p < 0.001) and at 12 months (37.9; 95% CI 36.4 to 39.3; p < 0.001). The SF-36 mental component summary mean at baseline was 42.5 (95% CI 40.8 to 44.2). At one month, it was unchanged (43.1; 95% CI 41.4 to 44.8; p = 0.458); it had improved statistically significantly at six months (47.1; 95% CI 45.4 to 48.7; p < 0.001) and at 12 months (46.7; 95% CI 45.0 to 48.5; p < 0.001). All mental subscales had improved by the end of the study, but mental health status remained compromised in comparison with the average USA population. Conclusion. BJIs considerably impact HRQoL, particularly mental health. Patients suffering from BJIs reported considerable limitations in their daily and social activities due to psychological problems. Impaired mental health may be explained by the chronic nature of BJIs, and therefore the mental wellbeing of these patients should be monitored closely. Cite this article: Bone Jt Open 2024;5(9):721–728


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 47 - 47
1 Apr 2022
Myatt D Stringer H Mason L Fischer B
Full Access

Introduction. Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Several studies demonstrate a high proportion of diaphyseal tibial fractures have ipsilateral occult posterior malleolus fractures, this ranges from 22–92.3%. Materials and Methods. A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture and who underwent a CT. The articular fracture extension was categorised into either posterior malleolar (PM) or other fracture. Results. 764 fractures were analysed, 300 had a CT. There were 127 intra-articular fractures. 83 (65.4%) cases were PM and 44 were other fractures. On univariate analysis for PM fractures, fibular spiral (p=.016) fractures, no fibular fracture(p=.003), lateral direction of the tibial fracture (p=.04), female gender (p=.002), AO 42B1 (p=.033) and an increasing angle of tibial fracture. On multivariate regression analysis a high angle of tibia fracture was significant. Other fracture extensions were associated with no fibular fracture (p=.002), medial direction of tibia fracture (p=.004), female gender (p=.000), and AO 42A1 (p=.004), 42A2 (p=.029), 42B3 (p=.035) and 42C2 (p=.032). On multivariate analysis, the lateral direction of tibia fracture, and AO classification 42A1 and 42A2 were significant. Conclusions. Articular extension happened in 42.3%. A number of factors were associated with the extension, however multivariate analysis did not create a suitable prediction model. Nevertheless, rotational tibia fractures with a high angle of fracture should have further investigation with a CT


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 93 - 93
23 Feb 2023
Thai T
Full Access

Conventional fracture courses utilise prefabricated sawbones that are not realistic or patient specific. The aim of this study is to determine the feasibility of creating 3D fracture models and utilising them in fracture courses to teach surgical technique. We selected an AO type 2R3C2 fracture that underwent open reduction internal fixation. De-identified CT scan images were converted to a stereolithography (STL) format. This was then processed using Computer Aided Design (CAD) to create a virtual 3D model. The model was 3D printed using a combination of standard thermoplastic polymer (STP) and a porous filler to create a realistic cortical and cancellous bone. A case-based sawbone workshop was organised for residents, unaccredited registrars, and orthopaedic trainees comparing the fracture model with a prefabricated T-split distal radius fracture. Pre-operative images aided discussion of fixation, and post-operative x-rays allowed comparison between the participants fixation. Participants were provided with identical reduction tools. We created a questionnaire for participants to rate their satisfaction and experience using a Likert scale. The 3D printed fracture model aided understanding and appreciation of the fracture pattern and key fragments amongst residents and unaccredited trainees. Real case-based models provided a superior learning experience and environment to aid teaching. The generic sawbone provided easier drilling and inserting of screws. Preliminary results show that the cost of 3D printing can be comparable to generic sawbones. It is feasible to create a fracture model with a real bone feel. Further research and development is required to determine the optimum material to use for a more realistic feel. The use of 3D printed fracture models is feasible and provides an alternative to generic sawbone fracture models in providing surgical training to residents


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 29 - 29
23 Apr 2024
Ahmed T Upadhyay P Menawy ZE Kumar V Jayadeep J Chappell M Siddique A Shoaib A
Full Access

Introduction. Knee dislocations, vascular injuries and floating knee injuries can be initially managed by a external fixator. Fixator design constructs include the AO pattern and the Diamond pattern. However, these traditional constructs do not adhere to basic principles of external fixation. The Manchester pattern knee-spanning external fixator is a new construct pattern, which uses beam loading and multiplanar fixation. There is no data on any construct pattern. This study compares the stability of these designs. Materials & Methods. Hoffman III (Stryker, USA) external fixation constructs were applied to articulated models of the lower limb, spanning the knee with a diamond pattern and a Manchester pattern. The stiffness was loaded both statically and cyclically with a Bose 3510 Electroforce mechanical testing jig (TA Instruments). A ramp to load test was performed initially and cyclical loading for measurement of stiffness over the test period. The results were analysed with a paired t-test and ANOVA. Results. The mean stiffness with the diamond pattern fixator was significantly less stiff than the Manchester pattern fixator – by a factor of 3 (40N/mm vs 115N/mm). Displacement increased in all patterns over simulated loading equating to six weeks. The diamond pattern demonstrated a 50%% increase in displacement over time. The Manchester pattern demonstrated only 20% increase in displacement over time. These are all statistically significant (p<0.01). Conclusions. The aim of an external fixator in knee dislocations and vascular injuries is to provide stability, prevent displacement and protect repairs. Vascular injuries often require fixation for several weeks to protect a repair. The Manchester pattern, applying the principles of external fixation, provides a stiffer construct and also confers greater stability over the time a fixator may be required. We commend this more informed design for the management of knee dislocations and vascular injuries


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 102 - 102
10 Feb 2023
White J Wadhawan A Min H Rabi Y Schmutz B Dowling J Tchernegovski A Bourgeat P Tetsworth K Fripp J Mitchell G Hacking C Williamson F Schuetz M
Full Access

Distal radius fractures (DRFs) are one of the most common types of fracture and one which is often treated surgically. Standard X-rays are obtained for DRFs, and in most cases that have an intra-articular component, a routine CT is also performed. However, it is estimated that CT is only required in 20% of cases and therefore routine CT's results in the overutilisation of resources burdening radiology and emergency departments. In this study, we explore the feasibility of using deep learning to differentiate intra- and extra-articular DRFs automatically and help streamline which fractures require a CT. Retrospectively x-ray images were retrieved from 615 DRF patients who were treated with an ORIF at the Royal Brisbane and Women's Hospital. The images were classified into AO Type A, B or C fractures by three training registrars supervised by a consultant. Deep learning was utilised in a two-stage process: 1) localise and focus the region of interest around the wrist using the YOLOv5 object detection network and 2) classify the fracture using a EfficientNet-B3 network to differentiate intra- and extra-articular fractures. The distal radius region of interest (ROI) detection stage using the ensemble model of YOLO networks detected all ROIs on the test set with no false positives. The average intersection over union between the YOLO detections and the ROI ground truth was Error! Digit expected.. The DRF classification stage using the EfficientNet-B3 ensemble achieved an area under the receiver operating characteristic curve of 0.82 for differentiating intra-articular fractures. The proposed DRF classification framework using ensemble models of YOLO and EfficientNet achieved satisfactory performance in intra- and extra-articular fracture classification. This work demonstrates the potential in automatic fracture characterization using deep learning and can serve to streamline decision making for axial imaging helping to reduce unnecessary CT scans


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 13 - 13
10 May 2024
Lynch-Larkin J Powell A
Full Access

Introduction. A subset of patients in cast awaiting fixation of ankle fractures require conversion to delayed external fixation (dEF). We aimed to evaluate the effect of delayed versus planned external fixation (pEF), then identify objective characteristics contributing to need for conversion. Method. We extracted data from our booking system to identify all ankle external fixation procedures between 2010 to 2022. Exclusions included open fractures, the skeletally immature, and pilon or talus fractures. Fractures were classified using the AO/OTA classification, then a matched cohort was identified based on fracture classification. We compared the planned, delayed and matched cohorts for demographics, posterior malleolar fragment (PMF) ratio, and degree of displacement at presentation. Results. We identified 25 pEF, 42 dEF, and 67 matched patients. Ankles with dEF had a 3.8 day longer time to ORIF from presentation than those who had pEF, and had an infection rate of 9.5%, compared to 4% in the pEF group. Two patients in the dEF group required further operative intervention. There were no infections or reoperations required in the pEF or matched groups. The dEF group were more likely to have ≥2 reductions (OR 4.13), a PMF ratio of >0.23 (OR 5.07), and have increased displacement at time of injury on lateral (32% vs 19%) and AP (62% vs 36%) radiographs. Discussion. Our retrospective study highlights the longer time to operation and increased infection rates of patients who do not get timely external fixation. We propose a series of objective parameters that predict failure of cast treatment and guide the surgeon to consider planned external fixation in some ankle


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 40 - 40
10 May 2024
Zhang J Miller R Chuang T
Full Access

Introduction. Distal femur fractures have traditionally been stabilized with either lateral locking plate or retrograde intramedullary nail. Dual-plates and nail-plate combination fixation have the theoretical biomechanical advantage, faster union and allows patients to weight bear immediately. The aim of this study is to compare single vs combination fixation, and evaluate outcomes and complications. Method. We retrospectively reviewed all patients over 60, admitted to Christchurch Hospital, between 1st Jan 2016 and 31st Dec 2022, with an AO 33A/33B/33C distal femur fracture. Patient demographics, fracture characteristics, operation details, and follow up data were recorded. Primary outcomes are union rate, ambulatory status at discharge, and surgical complications. Secondary outcomes include quality of reduction, operation time and rate of blood transfusions. Results. 114 patients were included. (92 single fixation, 22 combination fixation). Baseline demographic data and fracture characteristics did not differ between the cohorts. There was no difference in the rate of union or time to union between the two cohorts. Combination fixation patients were allowed to weight-bear as tolerated significantly more than single fixation patients (50% vs 18.9%, p=0.003). There was no difference in length of hospital stay, transfusion, complication and mortality rates. Medial translation of the distal articular block was significantly lower in the combination fixation cohort (1.2% vs 3.4%, p=0.021). Operation time was significantly longer in the combination fixation cohort (183mins vs 134mins, p<0.001). Discussion. The results show no difference in achieving union or time to union, despite better quality of fracture reduction with dual fixation. This differs to previously published literature. The clear benefit of combination fixation is immediate weight-bearing. As expected, operation times were longer with combination fixation, however this did not translate to more complications. Conclusion. Combination fixation allows earlier weight bearing, at the cost of longer operation times


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 105 - 105
1 Jul 2020
Gusnowski E Schneider P Thomas K
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO classification or a two-tailed independent samples t-test for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, 6 dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO classification versus 6 dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9o, SD 9.3, n=257, volar 61.3o, SD 11.5, n=1906) and extension (dorsal 60.0o, SD 12, n=257, volar 62.8o, SD 11.4, n=1906) were statistically significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of AO type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14.01, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5o, which is unlikely to be clinically significant. Additionally, we did not find a significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 109 - 109
10 Feb 2023
Sun J Tan SE Sevao J
Full Access

Anatomically specific fixation devices have become mainstream, yet there are anatomical regions and clinical conditions where no pre-contoured plates are available, such as for glenohumeral arthrodesis. In a case series of 4 glenohumeral arthrodesis patients, a consultant orthopaedic surgeon at GCUH implemented 3D printing technology to create reconstructions of each patient's shoulder girdle to pre-contour arthrodesis plates. Our aim was to quantify the cost-benefit & intra-operative time savings of this technique in glenohumeral arthrodesis. We hypothesized that the use of 3D printing for creating patient specific implants through pre-operative contouring of plates will lead to intra-operative time and cost savings by minimising time spent bending plates during surgery. This study analysed 4 patients who underwent shoulder arthrodesis by a single consultant orthopaedic surgeon at GCUH between 2017-2021. A CT-based life-size model of each patient's shoulder girdle was 3D printed using freely available computer software programs: 3D Slicer, Blender, Mesh Mixer & Cura. Once the patient's 3D model was created, plate benders were used to contour the plate pre-op, which was then sterilised prior to surgery. Arthrodesis was performed according to AO principles of fixation. The time spent pre-bending the plate using the 3D model was calculated to analyse the intra-op time and cost-saving benefits. For the 4 cases, the plate pre-bending times were 45, 40, 45 & 20 minutes (average 38.8 mins). The intra-op correction time to make small adjustments to the plate was 2 min/ case. 3 plates needed minor (3 degree) adjustment to fine-tune scapula spine contouring. 1 plate needed a 5 degree correction to fine-tune hand position. On average, the pre-bending of the plate saved approximately 38.8 mins intra-op/ case. These shorter anaesthetic and operating times equate to approximately $2586 saving/ case, given an estimate of $4000/hour of theatre costs. We conclude that pre-bending plates around 3D-printed life-size models of an individual's shoulder girdle prior to surgery results in approximately 38.8 mins time saving intra-op when used in shoulder arthrodesis. This is a viable and effective technique that will ultimately result in significant operative time and financial savings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 81 - 81
24 Nov 2023
Weisemann F Siverino C Trenkwalder K Heider A Moriarty F Hackl S
Full Access

Aim. Differentiation of infected (INF) nonunion from aseptic (AS) nonunion is crucial for the choice of intra- and postoperative treatment. Preoperative diagnosis of infected nonunion is challenging, especially in case of low-grade infection lacking clinical signs of infection. Standard blood markers such as C-reactive protein or leucocyte count do not aid in preoperative diagnosis. Proteomic profiling has shown promising results for differentiation of numerous chronic disease states, and in this study was applied to preoperative blood samples of patients with nonunion in an attempt to identify potential biomarkers. Method. This prospective multicenter study enrolled patients undergoing revision surgery of femur or tibia nonunion. Patients with implant removal after regular fracture healing (HEAL) were included as a control-group. Preoperative blood samples, intraoperative tissue samples, sonication of osteosynthesis material and 1-year-follow-up questionnaire were taken. Nonunion patients were grouped into INF or AS after assessing bacterial culture and histopathology of retrieved samples. Diagnosis of infection followed the fracture related infection consensus group criteria, with additional consideration of healing one year after revision surgery. Targeted proteomics was used to investigate a predefined panel of 45 cytokines in preoperative blood samples. Statistical differences were calculated with Kruskal Wallis and Dunn's post hoc test. Cytokines with less than 80% of samples being above the lower limit of detection range (LLDR) were excluded for this study. Results. We recruited 62 AS, 43 INF and 32 HEAL patients. Patients in the two nonunion groups (INF and AS) did not differ concerning smoking, diabetes or initial open or closed fracture. Thirty-two cytokines were above LLDR in >80% of patients. INF patients showed a significant difference in expression of 8 cytokines compared to AS, with greatest differences observed for Macrophage Colony Stimulating Factor 1 (MCSF-1) and Hepatocyte Growth Factor (HGF) (p<0.01). In comparing AS with HEAL patients, 9 cytokines displayed significant differences, including interleukin (IL)-6, Vascular Endothelial Growth Factor A (VEGFA), Matrix Metalloproteinase 1 (MMP-1). Comparison of INF with HEAL patients revealed significantly different expression of 20 cytokines, including. IL-6, IL-18, VEGFA or MMP-1. Conclusions. Our study revealed differences in plasma cytokine profile of blood samples from INF and AS patients. Although no single biomarker is sufficient to differentiate these patients preoperatively in isolation, future multivariant analysis of this cytokine data in combination with clinical characteristics may provide valuable diagnostic insights. Funded by German Social Accident Insurance (FF-FR 0276) and AO Trauma (AR2021_04)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 44 - 44
1 Nov 2022
Khadabadi N Murrell J Selzer G Moores T Hossain F
Full Access

Abstract. Introduction. We aimed to compare the outcomes of elderly patients with periarticular distal femur or supracondylar periprosthetic fractures treated with either open reduction internal fixation or distal femoral replacement. Methods. A retrospective review of patients over 65 years with AO Type B and C fractures of the distal femur or Su type I and II periprosthetic fractures treated with either a DFR or ORIF was undertaken. Outcomes including Length of Stay, PROMs (Oxford Knee Score and EQ 5D), infection, union, mortality, complication and reoperation rates were assessed. Data on confounding variables were also collected for multivariate analysis. Patients below 65 years and extra articular fractures were excluded. Results. 23 patients (11 in DFR group and 12 in ORIF group) fulfilled inclusion criteria and were included in the analysis. There was no difference between the DFR and ORIF groups with respect to SDI, demographic variables, ASA grade, FCI, preoperative Hb and renal function. There was no difference in 30 day mortality, reoperation rates, 30 day readmission rates and LOS between the two groups. Mean follow up was 12.7 and 15.9 months respectively in the DFR and ORIF groups. At final follow up after accounting for all confounding variables on multivariate analysis, functional outcomes using OKS (adjusted mean: 29.5 vs 15.8) and Health related Quality of Life outcomes using EQ 5D (adjusted mean: 0.453 vs −0.07) were significantly better in the DFR group. Conclusion. DFR for periarticular and periprosthetic distal femoral fractures in the elderly are associated with better patient reported outcomes


Acute Compartment Syndrome (ACS) is an orthopaedic emergency that can develop after a wide array of etiologies. In this pilot study the MY01 device was used to assess its ease of use and its ability to continuously reflect the intracompartmental pressure (ICP) and transmit this data to a mobile device in real time. This preliminary data is from the lead site which is presently expanding data collection to five other sites as part of a multi-center study. Patients with long bone trauma of the lower or upper extremity posing a possibility of developing compartment syndrome were enrolled in the study. Informed consent was obtained from the patients. A Health Canada licensed continuous compartmental pressure monitor (MY01) was used to measure ICP. The device was inserted in the compartment that was deemed most likely to develop ACS and ICP was continuously measured for up to 18 hours. Fractures were classified according to the AO/OTA classification. Patient clinical signs and pain levels were recorded by healthcare staff during routine in-patient monitoring and were compared to the ICP from the device. Important treatment information was pulled from the patient's chart to help correlate all of the patient's data and symptoms. The study period was conducted from November 2020 through December 2021. Twenty-six patients were enrolled. There were 17 males, and nine females. The mean age was 38 years (range, 17–76). Seventeen patients received the device post-operatively and nine received it pre-operatively. Preliminary results show that post-operative ICPs tend to be significantly higher than pre-operative ICPs but tend to trend downwards very quickly. The trend in this measurement appears to be more significant than absolute numbers which is a real change from the previous literature. One patient pre-operatively illustrated a steep trend upwards with minimal clinical symptoms but required compartment release at the time of surgery that exhibited no muscle necrosis. The trend in this patient was very steep and, as predicted, predated the clinical findings of compartment syndrome. This trend allows an early warning signal of the absolute pressure, to come, in the compartment that is being assessed by the device. Preliminary results suggest that this device is reliable and relatively easy to use within our institutions. In addition it suggests that intracompartmental pressures can be higher immediately post-op but lower rapidly when the patient does not develop ACS. These results are in line with current literature of the difference between pre and post-operative baselines and thresholds of ICP, but are much more striking, as continuous measurements have not been part of the data set in most of past studies. Further elucidation of the pressure thresholds and profiles are currently being studied in the ongoing larger multicenter study and will add to our understanding of the critical values. This data, plus the added value of continuous trends in the pressure, upwards or downwards, will aid in preventing muscle necrosis during our management of these difficult long bone fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 14 - 14
23 Jul 2024
Nugur A Wilkinson D Santhanam S Lal A Mumtaz H Goel A
Full Access

Introduction. Distal femur fracture fixation in elderly presents significant challenges due to osteoporosis and associated comorbidities. There has been an evolution in the management of these fractures with a description of various surgical techniques and fixation methods; however, currently, there is no consensus on the standard of care. Non-union rates of up to 19% and mortality rates of up to 26 % at one year have been reported in the literature. Delay in surgery and delay in mobilisation post-operatively have been identified as two main factors for high rate of mortality. As biomechanical studies have proved better stability with dual plating or nail-plate combination, a trend has been shifting for past few years towards rigid fixation to allow early mobilisation. Our study aims to compare outcomes of distal femur fractures managed with either single plate (SP), dual plating (DP) or nail-plate construct (NP). Methods. A retrospective review of patients aged above 65 years with distal femur fractures (both native and peri-prosthetic) who underwent surgical management between June 2020 and May 2023 was conducted. Patients were divided into three groups based on mode of fixation - single plate or dual plating or nail-plate construct. AO/OTA classification was used for non-periprosthetic, and Unified classification system (UCS) was used for periprosthetic fractures. Data on patient demographics, fracture characteristics, surgical details, postoperative complications, re-operation rate, radiological outcomes and mortality rate were evaluated. Primary objective was to compare re-operation rate and mortality rate between 3 groups at 30 days, 6 months and at 1 year. Results. A cohort of 32 patients with distal femur fractures were included in this study. 91% were females and mean age was 80.97 (range 68–97). 18 (53%) were non-periprosthetic fracture and 14 (47%) were periprosthetic fractures.18 patients underwent single plate fixation (AO/OTA 33A – 8, 33B/C – 2, UCS V3B – 5, V3C – 3),10 patients had dual plate fixation (AO/OTA 33A – 1, 33B/C – 4, UCS V3B – 3, V3C – 2) and 4 patients underwent nail-plate combination fixation (AO/OTA 33A – 4). 70.5% patients had surgery within 36 hours of admission and 90% within 48 hours. Analysis showed no re-operation at 30 days, 6 months in all 3 groups. At 1 year one patient had re-operation in dual-plating periprosthetic group (Distal femur replacement done for failed fixation). Three patients (16%) in single plate group had re-operation at 2 years (2 for peri-implant fracture and 1 for infection). None of the patients treated with Nail-plate combination had re-operation. Mortality rate at 30 days was 0% in among all the 3 groups. At 6 months, it was 16% in single plate group and 0% in DP and NP groups at 6 months and at 1 year mortality rate was 27% in SP group, 10% in DP and 0% in NP group. Combined mortality rate was 0% at 30 days, 9% at 6 months and 18.7% at one year. Conclusion. Our analysis provides insights into fixation methods of distal femur fractures in elderly patients. We conclude that a lower re-operation rate and mortality rate can be achieved with early surgery and rigid fixation with either dual plating or nail-plate construct to allow early mobilisation. Further prospective studies are warranted to confirm these findings and guide the selection of optimal surgical strategies for these challenging fractures