Background. Current literature of definition, classification and outcomes of fractures of talar body remains controversial. Our primary purpose is to present an unusual combination of fractures of talar body with pantalar involvement / dislocation / extension as a basis for modification of Müller
Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and
Objectives. Distal humerus fractures in elderly population are often comminuted and presents multiple challenges. When managed with fixation the results are often complicated with stiffness, pain, and reduced function while total elbow replacement is fraught with lifelong restrictions on load bearing which can significantly affect elderly patients who rely assistive devices for ambulation. Elbow hemiarthroplasty however, presents a viable alternative in these cases. This series evaluates the results of the distal humerus hemiarthroplasty in a single centre. Designs and methods. Data was collected retrospectively. Comprehensive case reviews were done to collect demographic, intra-operative and post-operative data. Fractures were classified as per
Introduction. Non-union is debilitating, costly and affects 2–8% of intramedullary fixed fractures. Clinical data suggest that percutaneous interfragmentary screws offer a less invasive alternative to exchange nailing. This study aimed to assess their efficiency with biomechanical analyses. Materials and Methods. A tibia was prepared for finite element analysis by creating a fracture of
Introduction. Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Several studies demonstrate a high proportion of diaphyseal tibial fractures have ipsilateral occult posterior malleolus fractures, this ranges from 22–92.3%. Materials and Methods. A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture and who underwent a CT. The articular fracture extension was categorised into either posterior malleolar (PM) or other fracture. Results. 764 fractures were analysed, 300 had a CT. There were 127 intra-articular fractures. 83 (65.4%) cases were PM and 44 were other fractures. On univariate analysis for PM fractures, fibular spiral (p=.016) fractures, no fibular fracture(p=.003), lateral direction of the tibial fracture (p=.04), female gender (p=.002), AO 42B1 (p=.033) and an increasing angle of tibial fracture. On multivariate regression analysis a high angle of tibia fracture was significant. Other fracture extensions were associated with no fibular fracture (p=.002), medial direction of tibia fracture (p=.004), female gender (p=.000), and AO 42A1 (p=.004), 42A2 (p=.029), 42B3 (p=.035) and 42C2 (p=.032). On multivariate analysis, the lateral direction of tibia fracture, and
Introduction. A subset of patients in cast awaiting fixation of ankle fractures require conversion to delayed external fixation (dEF). We aimed to evaluate the effect of delayed versus planned external fixation (pEF), then identify objective characteristics contributing to need for conversion. Method. We extracted data from our booking system to identify all ankle external fixation procedures between 2010 to 2022. Exclusions included open fractures, the skeletally immature, and pilon or talus fractures. Fractures were classified using the
Aim. Determine the incidence of surgical site infections (SSI) after intramedullary nailing (IN) of femoral and tibial diaphyseal fractures and evaluate possible risk factors. Method. Prospective observational cohort study. SSI was defined according to CDC-NHSN criteria and surveillance period for the occurrence of infection was 12 months instead of the 90 days currently recommended. Incidence was calculated as the ratio between the number of patients with SSI and total number of patients. Analysis of potential risk factors included patients-related factors (age, gender, body mass index, active foci of infection, immunosuppressive conditions, ASA score, alcohol or illicit drug abuse, smoking, polytrauma, etiology of fracture, type of fracture if closed or open, classification of fracture according to Müller
Stable thoracolumbar fracture is a common injury. The factors that determine its outcome are unclear. Aspects of injury severity were analysed for their ability to predict outcome by controlling other outcome-affecting factors (patient's pre-injury health status, legal aspects, associated injuries, etc.). No reliable disc injury severity grading system was available and therefore a new system was developed. A prospective observational study of 44 conservatively treated patients with stable fractures between T11 and L5 was conducted. Bony injury severity was scored based on comminution, apposition and kyphosis parameters. Disc injury severity was scored by the new scale based on variables – Herniation, Indentation, Height decrease and Signal change – seen in MRI. Ten outcome domains (five domains of pain and function each) were assessed at 1 to 2 years from injury. The data was analysed by non-parametric correlation and stepwise-linear regression analysis to assess the predictive value of different variables (patient factors, injury factors and social factor) to outcome. The correlation coefficients between injury severity and outcome were consistently higher with disc injury severity than bony. Disc injury severity showed highest predictive value for both pain (29%) and functional (16%) outcomes, whereas the bony injury severity parameters (kyphosis, etc.) and the posterior ligament injury severity provided no prediction of outcome. According to
Acute Compartment Syndrome (ACS) is an orthopaedic emergency that can develop after a wide array of etiologies. In this pilot study the MY01 device was used to assess its ease of use and its ability to continuously reflect the intracompartmental pressure (ICP) and transmit this data to a mobile device in real time. This preliminary data is from the lead site which is presently expanding data collection to five other sites as part of a multi-center study. Patients with long bone trauma of the lower or upper extremity posing a possibility of developing compartment syndrome were enrolled in the study. Informed consent was obtained from the patients. A Health Canada licensed continuous compartmental pressure monitor (MY01) was used to measure ICP. The device was inserted in the compartment that was deemed most likely to develop ACS and ICP was continuously measured for up to 18 hours. Fractures were classified according to the
Introduction. Distal femur fracture fixation in elderly presents significant challenges due to osteoporosis and associated comorbidities. There has been an evolution in the management of these fractures with a description of various surgical techniques and fixation methods; however, currently, there is no consensus on the standard of care. Non-union rates of up to 19% and mortality rates of up to 26 % at one year have been reported in the literature. Delay in surgery and delay in mobilisation post-operatively have been identified as two main factors for high rate of mortality. As biomechanical studies have proved better stability with dual plating or nail-plate combination, a trend has been shifting for past few years towards rigid fixation to allow early mobilisation. Our study aims to compare outcomes of distal femur fractures managed with either single plate (SP), dual plating (DP) or nail-plate construct (NP). Methods. A retrospective review of patients aged above 65 years with distal femur fractures (both native and peri-prosthetic) who underwent surgical management between June 2020 and May 2023 was conducted. Patients were divided into three groups based on mode of fixation - single plate or dual plating or nail-plate construct.
The purpose of this study was to review the outcomes and complications of all circular external fixators (frames) used for the management of acute lower limb trauma in our institution over a twenty year period. We retrospectively reviewed a prospectively compiled database of all frames applied in our institution and identified all frames which were applied for acute lower limb trauma. We identified 68 fractures in 63 patients. There were 11 femoral fractures and 57 tibial fractures. All fractures were classified using the
Purpose of study:. The presence of an L5 transverse process fracture is reported in many texts to be a marker of pelvis fracture instability. There is paucity of literature to support this view. Available studies have been performed on patients who were already known to have a pelvis fracture. No study has attempted to document the presence of this lesion in the absence of a pelvis fracture. Primary aim: To identify the correlation between the presence of a L5 transverse process fracture and an unstable pelvic ring injury. Secondary aim: To establish whether a L5 transverse process fracture can occur in the absence of a pelvis fracture. Methods:. We conducted a retrospective review of all CT scans performed in patients who presented to a Level 1 Trauma Unit for blunt abdomino-pelvic trauma between January 1, 2012 and August 28, 2013. A total of 203 patients met our inclusion criteria. Results:. Fifty four of these 203 patients (26%) sustained a pelvis fracture. Of these 54 patients 26 (48%) had an unstable fracture pattern according to the
Background. Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at mean 24-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon (CFR-PEEK) for the treatment of distal radius fractures. Materials and methods. We performed a prospective study including all patients who were treated for unstable distal radius fracture with a CFR-PEEK volar fixed angle plate. We included 70 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the
Approximately 20% of patients with ankle fracture sustain syndesmosis injury. This is most common in trans-syndesmotic (type B) and supra-syndesmotic (type C) fibula fractures. Intra-operative assessment of syndesmosis integrity is important because failure to treat these injuries can result in ankle instability and pain. Our aim was to audit the documentation of intra-operative testing of syndesmosis during ankle fracture open reduction and internal fixation (ORIF). All patients who had ankle fracture ORIF between 1/1/2010 and 21/11/2011 were included. Pre-operative radiographs were reviewed and fractures were classified according to
The aim of this study was to establish any association between implant cut-out and a Tip Apex Distance (TAD), ≥25mm, in proximal femoral fractures, following closed reduction and stabilisation, with either a Dynamic Hip Screw (DHS) or Intramedullary Hip Screw (IMHS) device. Furthermore, we investigated whether any difference in cut-out rate was related to fracture configuration or implant type. WE conducted a retrospective review of the full clinical records and radiographs of 65 consecutive patients, who underwent either DHS or IMHS fixation of proximal femoral fractures. The TAD was measured in the standard fashion using the combined measured AP and lateral radiograph distances. Fractures were classified according to the Muller
Fractures of the proximal femur at the level of the lesser trochanter (reversed and transverse fracture lines, Evans classification type II,
Introduction. Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal Femoral Nail Antirotation (PFNA) is a recently introduced implant from AO/ASIF designed to compact the cancellous bone and may be particularly useful in unstable and osteoporotic hip fractures. This study is a single and independent centre experience of this implant used in management of acute hip fractures. Methods. 68 patients involving 68 PFNA nailing procedures done over a period of 2 years (2007–09) were included in the study. Average follow-up period of patients was 1 year.
Distal radius fractures are among the most common fractures seen in the emergency department. Closed reduction can provide definitive management when acceptable radiographic parameters are met. Repeated attempts of closed reduction are often performed to improve the alignment and avoid operative management. However, multiple reduction attempts may worsen dorsal comminution and lead to eventual loss of reduction, resulting in no demonstrable benefit. We hypothesize that compared to one closed reduction attempt, repeated closed reduction of extra-articular, dorsally angulated, displaced distal radius fractures has a low success rate in the prevention of operative fixation and improvement of radiographic parameters. Initial and post reduction radiographs for all distal radius fractures managed at Vancouver General Hospital between 2015 and 2018 were reviewed. Inclusion criteria were based on the
Distal radius fractures are among the most common fractures seen in the emergency department. Closed reduction can provide definitive management when acceptable radiographic parameters are met. Repeated attempts of closed reduction are often performed to improve the alignment and avoid operative management. However, multiple reduction attempts may worsen dorsal comminution and lead to eventual loss of reduction, resulting in no demonstrable benefit. We hypothesize that compared to one closed reduction attempt, repeated closed reduction of extra-articular, dorsally angulated, displaced distal radius fractures has a low success rate in the prevention of operative fixation and improvement of radiographic parameters. Initial and post reduction radiographs for all distal radius fractures managed at Vancouver General Hospital between 2015 and 2018 were reviewed. Inclusion criteria were based on the
Introduction. Minimally invasive plate osteosynthesis (MIPO) is a relatively new surgical technique for the management of distal tibial fractures. Conventional open technique is unfavourable to the fracture biology because of excessive soft tissue stripping and can be associated with significant devastating complications. Objective. The aim of this study was to determine the effectiveness of the MIPO technique for distal tibial fractures. Methods. Between 2004 and 2010 twenty-nine consecutive patients had distal tibial fractures treated with MIPO by the senior author. An anteromedial plate (Synthes®) was used for all patients. Case notes and radiographs of all patients were reviewed and data, including demographics, fracture classification, complications and fracture healing were recorded on a database. Results. 29 Patients with a median age of 46 (range 25–82) were reviewed. 12 were female and 17 were male. Mean follow-up was 6.24 months. Using the