Advertisement for orthosearch.org.uk
Results 1 - 20 of 81
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 6 - 6
1 Jul 2020
Hall A Holt G
Full Access

Background. National hip fracture programmes are becoming widespread, but this practice is nascent and varied. The Scottish Hip Fracture Audit (SHFA) was an early adopter of this strategy and is credited with substantial systemic improvements in quality and outcomes. Objectives. To provide evidence and incentive to clinicians and administrators to adopt successful improvement strategies, and to facilitate data-driven change hip fracture care. Study Design and Methods. We reviewed the practice of seven national hip fracture improvement programmes in: Sweden, Denmark, Norway, Australia, New Zealand, UK, Scotland, and Ireland. We report our experience from the SHFA and describe: the results of our programme; challenges and learning points encountered, and successful strategies for implementing change. Results. There is variance in approach to data collection and reporting, for example: standalone programmes versus combined trauma and arthroplasty registries; annual trend reporting versus ‘snapshot’ or real-time information; population-level versus patient-level data, and the emphasis placed on service-level characteristics. The governance model also varies – some act as a passive data registry whereas others act as active agents of change and regulation. There is consensus on the key performance makers: prompt admission; early surgery and mobilisation, and a multidisciplinary approach. There have been significant challenges encountered by the SHFA with respect to funding, logistical, and political issues. Analysis of the effects of our programme have demonstrated its clinical efficacy, and has identified successful strategies for improvement. We describe this experience. Conclusions. The establishment of national audit programmes has resulted in significant improvements in quality, efficiency, and outcomes. This study of major national programmes provides evidence, incentive, and instruction to clinicians and administrators who seek to improve healthcare systems


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 888 - 897
3 May 2021
Hall AJ Clement ND MacLullich AMJ White TO Duckworth AD

Aims

The primary aim was to determine the influence of COVID-19 on 30-day mortality following hip fracture. Secondary aims were to determine predictors of COVID-19 status on presentation and later in the admission; the rate of hospital acquired COVID-19; and the predictive value of negative swabs on admission.

Methods

A nationwide multicentre retrospective cohort study was conducted of all patients presenting with a hip fracture to 17 Scottish centres in March and April 2020. Demographics, presentation blood tests, COVID-19 status, Nottingham Hip Fracture Score, management, length of stay, and 30-day mortality were recorded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 13 - 13
7 Jun 2023
Diffley T Ferry J Sumarlie R Beshr M Chen B Clement N Farrow L
Full Access

Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/A2 fracture configurations. Differences in LOS potentially increases costs by £1230 per-patient, irrespective of the higher costs of IMN's v SHS. Appropriate SHS use is associated with early mobilisation, reduced LOS and likely with reduced cost of treatment. Further research exploring potential reasons for the identified differences in early mobilisation are warranted


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 44 - 44
1 Jun 2016
Sellars H Sandiford N Charity J
Full Access

Introduction. Reoperation within thirty days after hip fracture surgery is associated with increased mortality, length of stay and cost of care. The United Kingdom National Hip Fracture Database (NHFD) reported a significant increase in the 30-day reoperation rate for patients undergoing surgery for hip fractures in our unit from 2012 to 2014. We audited our data in order to validate this and identify any reversible trends. Methods. Between January 2012 and December 2014, 1757 consecutive procedures for hip fracture were performed in our unit. Patients who had a reoperation within 30 days and those recorded as ‘unknown’ under the reoperation category were identified. Patients with hip dislocations were included. Patient demographics, diagnosis, treatment and outcomes were recorded. This was compared with reoperation for all causes after 30 days over a 12-month period. Results. Nineteen patients (1.1%) underwent a reoperation within 30-days. There was no significant change in the annual incidence over the period studied. Infection was the leading cause for reoperation (47%). The NHFD also reported a 10-fold increase in the incidence of periprosthetic fractures during the study period (0.18% to 1.78%). This did not correlate with our findings (0% to 0.36%). Our NHFD data entry system was unchanged over the 3-year period. We identified a change in NHFD data entry form in April 2014 which corresponded to the increase in the incidence of periprosthetic fractures and overall reoperation rates. Discussion. These results suggest there is a need for local validation of NHFD data. The current design may contribute to imprecise data recording. We suggest the introduction of an automatic notification system informing the local NHFD lead of any reoperation within 30 days would assist in real-time monitoring. This study led us to identify infection as the leading cause of reoperation at our institution and initiate improvement measures


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 13 - 13
1 Nov 2015
Lee L
Full Access

Introduction

The National Institute for Health and Care Excellence (NICE) currently recommends the use of total hip replacement (THR) for displaced intracapsular hip fractures in cognitively competent patients and who were independently mobile with the maximum use of one stick prior to the injury.

Method

We conducted a prospective cross sectional study of the management of hip fractures within a defined geographic region in the North East of England to assess current practice and variation in provision of THR for displaced intracapsular hip fracture.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 62 - 62
2 May 2024
Afzal S Sephton B Wilkinson H Hodhody G Ammori M Kennedy J Hoggett L Board T
Full Access

Total Hip Arthroplasty (THA) and Hip Hemiarthroplasties (HA) are successful, cost-effective procedures that improve quality of life. Dislocation is a well recognised complication with a significant health and economic burden. We aim to establish the current management practices across the United Kingdom (UK) for Prosthetic Hip Dislocations (PHD). Our definition of a PHD includes; THA, HA and revision THA. This national study builds on our regional pilot study and records one of the largest datasets of Prosthetic Hip Dislocation management within the UK. A trainee-led collaborative; the North West Orthopaedic Research Collaborative (NWORC). Conducted a retrospective audit, registered as Quality Improvement (QI) projects, collected data from 38 hospital trusts across the UK. Data was collected on patient-related factors, inpatient management, and outpatient follow up of each PHD episode between January and July 2019. Primary outcome measured definitive management, in the form of revision surgery or the consideration for this through a referral pathway. A total of 673 (THA 504, Revision THA 141, HA 28) patients were included with a total of 740 dislocation episodes. Mean age was 75.6 years with female to male ratio 2:1. The majority of PHDs were a result of a low energy mechanism (98.7%) and presented over 6 months post index procedure (80.5%). Over half (53.8%) attended with a first or second time dislocation. Only 29.9% patients received onward revision referral; whereas 70.1% followed diverse management patterns, including local non-arthroplasty and primary arthroplasty surgeon follow-ups. Revision THAs had higher rates of referral for revision (p<0.001) compared to primary THA and HA dislocations. A high number of PHDs present across the UK, with under a third receiving definitive management plans. This variation increases the economical burden to the National Health Service, highlighting the need for national guidance to manage these complex patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 84 - 84
23 Jun 2023
Devane P
Full Access

At the end of 2018, the NZ Joint Registry introduced a “Surgeon Outlier” policy, whereby each year, if an individual surgeons’ lower 95% confidence interval of their revision rate, measured in revision/100 component years(r/ocys), was above the NZ mean (0.71 r/ocys), that surgeon was required to audit their results with a nominated peer. This study investigates whether outlier surgeons also have high early (1 month and 1 year) revision rates. In 2018, 236 surgeons performed 9,186 total hip arthroplasties in NZ. At the end of 2018, 11 surgeons received notification they were outliers. Results from all surgeons for years 2016, 2017 and 2018 were combined to form the first (pre-notification) time interval, and results from years 2019, 2020 and 2021 were combined to form the second time interval (post-notification). Outlier surgeons performed 2001 total hip replacements in the first time interval and 1947 hips in the second. Early revision rates (1 month and 1 year) of both outlier and nonoutlier surgeons for both time intervals were analysed. Non-outlier surgeons had a consistent mean early revision rate of 0.75% at one month and 1.6% at one year for both time intervals. The 11 outlier surgeons had a higher earlier revision rate of 1.35% at one month and 2.45% at one year for the pre-notification time interval. These values reduced for the post-notification time interval to a revision rate of 1.23% for one month and 2.36% for one year. Poor joint registry results of individual surgeons are often attributed to a poor choice of prosthesis. This study shows early revision rates of outlier surgeons, where prosthesis selection has minimal influence, are also high. A slight improvement in early revision rates of outlier surgeons since introduction of the policy shows it is working


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 20 - 20
2 May 2024
Khaled A Eyre-Brook A Petrie M Gordon A Harrison T Salih S
Full Access

The benefits of cell salvage autotransfusion are well reported. There is a common non-evidenced belief amongst revision arthroplasty surgeons that auto-transfusion is potentially contraindicated in infected revisions. The aim is to study the immediate and delayed outcomes of using cell saver on patients undergoing PJI surgery. Prospective cohort service evaluation registered with the local audit department. 20 PJI cases in 18 patients where cell saver was used over a period of 4 years. Intraoperative fluid and tissue samples were taken for culture. Blood culture from salvaged blood pre and post leucodepletion filter were sent for microbiological analysis. Data on type of surgery, blood loss, further allogenic transfusion and SIRS response was collected. Success of infection clearance was assessed using 2019 MSIS ORT. Five patients receiving autologous blood in non-infection cases were used as controls. Mean age for the PJI group was 67.7 years, 67% female. 11 patients (67%) had 1st stage surgery and 5 (25%) underwent 2nd stage whereas 4 patients had single stage surgery. The mean calculated blood loss was 1398 mls (range 400–3000mls). 6 Patients required further allogenic transfusion. 16 patients received blood via a leuco-depletion filter. The same organism grown from tissues was identified in post-filter blood in 8/17 patients (47%). 2/20 have grown a different organism in post-filtered blood, _P.Acne._. 2 patients developed SIRS upon auto-transfusion, however one was thought to be secondary to cementing. The control group had 443 mls mean amount of blood loss and 1 patient developed a SIRS response. 14/20 (70%) patients had successful clearance of infection (tier 1) 2 patients died prior to undergoing 2nd stage. Using cell saver did not impact main outcome of infection clearance in PJI surgery. We would advocate its routine usage whilst avoiding direct collection of heavily contaminated blood


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 38 - 38
7 Jun 2023
Ewels R Kassam A Evans J
Full Access

Electronic Health Records (EHRs) have benefits for hospitals and uptake in the UK is increasing. The National Joint Registry (NJR) monitors implant and surgeon performance and relies on accuracy of data. NJR data are used for identification of potential outliers for both mortality and revision; analyses are adjusted for age, sex, and American Society of Anaesthesiologists score (ASA) and cases with some indications are excluded from analyses. In October 2020, the Royal Devon University Hospitals NHS Foundation Trust “went live” on an EHR, almost eradicating paper from the Trust. This included stopping use of paper NJR forms by creating a bespoke electronic template. We sought to identify discrepancies between operation notes and data input to the NJR in variables that may influence potential outlier analyses. Data input to the NJR from 15/10/2020 to 18/10/2022 for hip procedures were provided by NEC Software Solutions. NJR data were compared to those recorded on operation notes. There were 1067 hip procedures recorded in the NJR (946 primary THRs). Of the primary THRs, discrepancies in indication between NJR and operation note were identified in 139 (15%) cases. Common discrepancies included cases being recorded as osteoarthritis where the true indication was acute trauma (n=63), avascular necrosis (n=14), metastatic cancer/malignancy (n=6) and 21 cases with no recorded indication. We identified 88 cases where the ASA recorded in the NJR differed from the anaesthetic chart. Other inaccuracies were identified including 23 cases missing type of procedure (e.g., primary or revision) and one where revision surgery had been recorded as primary. We identified at least 83 cases that should have been excluded from NJR mortality analyses but were not. Given the low incidence of mortality following primary THR, these cases (with increased risk of death) have the potential to incorrectly identify the hospital as a potential outlier. Discrepancies in ASA may also impact on both revision and mortality outlier calculations. We urge caution to hospitals in the implementation of EHRs and advise regular audit of data sent to the NJR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 30 - 30
7 Jun 2023
Harris E Farrow L Martin C Adam K
Full Access

Hip fracture represents a significant challenge, placing increasing pressure on health and social care services in Scotland. This study establishes the ‘historic’ hip fracture burden, namely, the annual number of hip fractures in Scotland, and respective incidence, between 2017 – 2021. Furthermore, the ‘projected’ hip fracture burden and incidence from 2022 – 2029 was estimated, to inform future capacity and funding of health and social care services. The number of individuals with a hip fracture in Scotland between 2017 and 2021 was identified through the Scottish Hip Fracture Audit, enabling the annual number of hip fractures and respective incidence between 2017 – 2021 to be calculated. Projection modelling was performed using Exponential Smoothing and Auto Regressive Integrated Moving Average to estimate the number of hip fractures occurring annually from 2022 – 2029. A combined average projection was employed to provide a more accurate forecast. Accounting for predicted changes within the population demographics of Scotland, the projected hip fracture incidence up to 2029 was calculated. Between 2017 and 2021 the annual number of hip fractures in Scotland increased from 6675 to 7797 (15%), with an increase in incidence from 313 to 350 per 100,000 (11%) of the at-risk population. Hip fracture was observed to increase across all groups, notably males, and the 70–79 and 80–89 age cohorts. By 2029, the combined average projection estimated the annual number of hip fractures at 10311, with an incidence rate of 463 per 100,000, representing a 32% increase from 2021. The largest percentage increase in hip fracture by 2029 occurs in the 70–79 and 80–89 age cohorts (57% and 53% respectively). Based upon these projections, overall length of hospital stay following hip fracture will increase by 60699 days per annum by 2029, incurring an additional cost of at least £25 million. Projection modelling demonstrates the annual number of hip fractures in Scotland will increase substantially by 2029, with significant implications for health and social care services. This increase in hip fracture burden and incidence is influenced strongly by changing population demographics, primarily an ageing population


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 55 - 55
1 Oct 2020
Barnes CL
Full Access

Introduction. Recent literature has sought to quantify pre-operative work associated with total joint arthroplasty. These studies have utilized surveys or self-reported time logs to estimate the Pre-op Optimization Work (POW) completed by the surgical team. The purpose of this study was to objectively quantify POW associated with total hip arthroplasty (THA) using electronic medical record (EMR) activity audit logs. Methods. Retrospective analysis of EMR activity for 4 arthroplasty surgeons and their clinical staff was collected for 100 consecutive THA cases (25 per surgeon). Clinical informatics data was generated using EMR activity audit logs for pre-THA activity. Every action and mouse-click within a patient's chart was recorded for each team member. The time between mouse-clicks was calculated and summed for each user. Times exceeding five minutes without activity were assumed to reflect inactivity and excluded. Descriptive statistics were used to estimate the POW associated with THA preparation. Results. The mean number of days for pre-THA time period was70.7 (SD43.9; range: 8–175days). During this period, the mean time spent in each patient's chart was 75.5 minutes (SD50.75) minutes. Surgeon's POW in the medical record accounted for 7.3(SD6.7) of these minutes. Much of the work was conducted by nurses (47.0 minutes, SD43.4), physician extenders (10.8 minutes, SD 13.1), and qualified office staff/technicians (10.4 minutes, SD14.9). The majority of work captured in the EMR activity log was associated with medication review, patient optimization, documentation of necessary medical clearances, ordersets, patient communication, and prior authorization requests. Conclusion. A considerable amount of preoperative work is required between the clinic date a patient decides to pursue THA and the day prior to surgery. These retrospective electronic time stamp measurements should represent the absolute minimum time required for surgical preparation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 20 - 20
1 Apr 2022
Afzal S Hodhody G Kennedy J Board T
Full Access

Total Hip Replacements (THR) and Hip Hemiarthroplasties (HA) are both successful and common orthopaedic procedures. Dislocation is a well-recognised complication carrying significant morbidity and, in some cases, increased mortality risks. We define prosthetic hip dislocations (PHDs) to include both THRs and HAs. Prosthetic Hip Dislocations (PHDs) are a common acute admission yet there are no published guidelines or consensus on management following reduction. A retrospective audit was undertaken by the North West Orthopaedic Research Collaborative (NWORC) between January 2019 and July 2019. A questionnaire was used to capture the management of each dislocation episode presenting to 11 Hospital trusts. The study was registered as a Quality Improvement (QI) project at each site. Data regarding the surgical management physiotherapy input, ongoing care and further management plans were recorded. A total of 183 patients with 229 dislocations were submitted for initial analysis (171 THRs, 10 HAs, 2 PFRs). Female to male ratio was 2:1 with mean age of 76.7 years. Average time to first dislocation was 8.1 years. 61.1% were first or second time dislocators and 38.9% presented with 3 or more dislocations. Initial reductions were predominantly attempted in theatre (96.5%, n=221) with only 3.5% (n=8) attempted in the emergency department. In theatre 89% (n=201) were reduced closed. There was no plan for revision surgery in 70.6% cases with no difference seen between patients with >=3 dislocations and <=2 dislocations. Of the patients with a revision plan, 71% of these were performed or planned locally. The high number of patients with 3 or more dislocations and the lack of plans for definitive interventions in the majority of cases highlights the significant variation in the management of this complex group of patients. This variation in the quality of care increases the burden on the National Health Service through repeat hospital episodes. We aim to roll out this study nationally to assess regional variations and ultimately make the case for national guidance on the management of prosthetic hip dislocations


Bone & Joint Open
Vol. 2, Issue 2 | Pages 93 - 102
1 Feb 2021
Thompson JW Wignadasan W Ibrahim M Beasley L Konan S Plastow R Magan A Haddad FS

Aims. We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon. Methods. We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed. Results. Our evaluation and critique of the evidence-based literature identifies day-case THA to be safe, effective, and economical, benefiting both patients and healthcare systems alike. We further validate this with our institutional elective day surgery arthroplasty pathway (EDSAP) and report a small cohort of successful day-case THA cases as an example in the early stages of this practice in our unit. Conclusion. Careful patient selection and education, adequate perioperative considerations, including multimodal analgesia, surgical technique and blood loss management protocols and appropriate postoperative pathways comprising reliable discharge criteria are essential for successful day-case THA. Cite this article: Bone Jt Open 2021;2(2):93–102


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 536 - 539
1 May 2019
Cassidy RS O hEireamhoin S Beverland DE

Aims. The aim of this retrospective audit was to determine the route of referral or presentation of patients requiring revision following primary total hip arthroplasty (THA). Patients and Methods. A total of 4802 patients were implanted with an Orthopaedic Data Evaluation Panel (ODEP) 10A* cementless implant (Corail/Pinnacle) between 2005 and 2015; 80 patients with a mean age of 67.8 years (. sd. 10.8) underwent a subsequent revision. The primary outcome measure was route of referral for revision. Results. Of the 80 revisions, 31 (38.8%) took place within the first year and 69 (86.3%) took place within six years. Only two of the 80 patients were picked up at a routine review clinic, one for infection and the other for liner dissociation. A total of 36 revised patients (45.0%) were reviewed following self-referral. Of the remaining 44 revised patients (55.0%), 15 (18.8%) were General Practitioner referrals, 13 (16.3%) were other hospital referrals, six (7.5%) were inpatients, six (7.5%) were Emergency Department referrals, and two (2.5%) were readmitted from their homes. No revisions were carried out on asymptomatic patients. Conclusion. Our experience suggests that if there is a robust system in place for self-referral, patients with an ODEP 10A* hip implant can, if asymptomatic, be safely discharged at the time of their first postoperative review. Cite this article: Bone Joint J 2019;101-B:536–539


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 40 - 40
1 May 2019
Vanhegan I Martin A Gundle R Taylor A Kendrick B
Full Access

Introduction. We are a high-volume arthroplasty unit performing over 800 primary THRs annually at an approximate reimbursement of £6.5 million to the Trust. 70% are hybrid and we have been using the Taperfit - Trinity combination (Corin, Cirencester) since March 2016. We aimed to investigate the potential cost-savings and clinical benefits of instrument rationalisation using this system following GIRFT principles. Methods. Taperfit (ODEP 10A) is a polished, collarless, double tapered stem available in multiple sizes/offsets. Trinity is a hemispherical porous titanium cementless shell. A prospective audit of implant size was performed for the first 50 cases. Based on these findings, instruments were reduced to a single tray per component based on predicted size, named ‘Corin Hip for the Osteoarthritic Patient’ (CHOP). A further re-audit was performed to confirm correct tray constituent sizes. Financial data were calculated using known TSSU costs of approximately £50 per tray. Results. The audit revealed 92% (46/50) of stem sizes 2 or smaller and 86% (43/50) of shell sizes 54 or smaller. Trays per case were then rationalised from 6 to 2. Each acetabular tray had seven reamers (‘CHOP 1’ 42, 46–56 or CHOP 2 46, 54–64) and each femoral tray had broaches sized 0–2 (CHOP 1) or 2–4 (CHOP 2). Re-audit confirmed the CHOP 1 sets covered approximately 85% of cases. A TSSU saving of £192/case was achieved. Additional benefits were: all trays easily kept under laminar flow, time spent counting instruments was reduced and theatre shelving space liberated. Conclusion. Rationalisation of surgical instruments has saved the Trust approximately £100,000/year. Fewer instruments potentially reduce the risk of ‘never events’ and infection. Industry savings on consigned instruments have been passed on with significant reduction in our implant procurement costs allowing the use of hybrid implants for the price of our all cemented combination


Aims

Delirium is associated with adverse outcomes following hip fracture, but the prevalence and significance of delirium for the prognosis and ongoing rehabilitation needs of patients admitted from home is less well studied. Here, we analyzed relationships between delirium in patients admitted from home with 1) mortality; 2) total length of hospital stay; 3) need for post-acute inpatient rehabilitation; and 4) hospital readmission within 180 days.

Methods

This observational study used routine clinical data in a consecutive sample of hip fracture patients aged ≥ 50 years admitted to a single large trauma centre during the COVID-19 pandemic between 1 March 2020 and 30 November 2021. Delirium was prospectively assessed as part of routine care by the 4 A’s Test (4AT), with most assessments performed in the emergency department. Associations were determined using logistic regression adjusted for age, sex, Scottish Index of Multiple Deprivation quintile, COVID-19 infection within 30 days, and American Society of Anesthesiologists grade.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 504 - 510
1 May 2023
Evans JT Salar O Whitehouse SL Sayers A Whitehouse MR Wilton T Hubble MJW

Aims

The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for primary total hip arthroplasty (THA). In 2004, the 44/00/125 stem was released for use in ‘cement-in-cement’ revision cases. It has, however, been used ‘off-label’ as a primary stem when patient anatomy requires a smaller stem with a 44 mm offset. We aimed to investigate survival of this implant in comparison to others in the range when used in primary THAs recorded in the NJR.

Methods

We analyzed 328,737 primary THAs using the Exeter V40 stem, comprising 34.3% of the 958,869 from the start of the NJR to December 2018. Our exposure was the stem, and the outcome was all-cause construct revision. We stratified analyses into four groups: constructs using the 44/00/125 stem, those using the 44/0/150 stem, those including a 35.5/125 stem, and constructs using any other Exeter V40 stem.


Aims

The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture.

Methods

This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 189 - 194
1 Feb 2024
Donald N Eniola G Deierl K

Aims

Hip fractures are some of the most common fractures encountered in orthopaedic practice. We aimed to identify whether perioperative hypotension is a predictor of 30-day mortality, and to stratify patient groups that would benefit from closer monitoring and early intervention. While there is literature on intraoperative blood pressure, there are limited studies examining pre- and postoperative blood pressure.

Methods

We conducted a prospective observational cohort study over a one-year period from December 2021 to December 2022. Patient demographic details, biochemical results, and haemodynamic observations were taken from electronic medical records. Statistical analysis was conducted with the Cox proportional hazards model, and the effects of independent variables estimated with the Wald statistic. Kaplan-Meier survival curves were estimated with the log-rank test.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.

Methods

We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.