Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1095 - 1100
1 Sep 2022
McNally MA Ferguson JY Scarborough M Ramsden A Stubbs DA Atkins BL

Aims. Excision of chronic osteomyelitic bone creates a dead space which must be managed to avoid early recurrence of infection. Systemic antibiotics cannot penetrate this space in high concentrations, so local treatment has become an attractive adjunct to surgery. The aim of this study was to present the mid- to long-term results of local treatment with gentamicin in a bioabsorbable ceramic carrier. Methods. A prospective series of 100 patients with Cierny-Mader Types III and IV chronic ostemyelitis, affecting 105 bones, were treated with a single-stage procedure including debridement, deep tissue sampling, local and systemic antibiotics, stabilization, and immediate skin closure. Chronic osteomyelitis was confirmed using strict diagnostic criteria. The mean follow-up was 6.05 years (4.2 to 8.4). Results. At final follow-up, six patients (six bones) had recurrent infection; thus 94% were infection-free. Three infections recurred in the first year, two in the second year, and one 4.5 years postoperatively. Recurrence was not significantly related to the physiological class of the patient (1/20 Class A (5%) vs 5/80 Class B (6.25%); p = 0.833), nor was it significantly related to the aetiology of the infection, the organisms which were cultured or the presence of nonunion before surgery (1/10 with nonunion (10%) vs 5/90 without nonunion (5.6%); p = 0.570). Organisms with intermediate or high-grade resistance to gentamicin were significantly more likely in polymicrobial infections (9/21; 42.8%) compared with monobacterial osteomyelitis (7/79 (8.9%); p < 0.001). However, recurrence was not significantly more frequent when a resistant organism was present (1/16 for resistant cases (6.25%) vs 5/84 in those with a microbiologically sensitive infection (5.95%); p = 0.958). Conclusion. We found that a single-stage protocol, including the use of a high-delivery local antibiotic ceramic carrier, was effective over a period of several years. The method can be used in a wide range of patients, including those with significant comorbidities and an infected nonunion. Cite this article: Bone Joint J 2022;104-B(9):1095–1100


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 86 - 86
1 Oct 2022
McNally M Ferguson J Scarborough M Ramsden A Stubbs D Atkins B
Full Access

Aim. Excision of chronic osteomyelitis (cOM) creates a dead space which must be managed to avoid early recurrence of infection. Systemic antimicrobials cannot penetrate this space in high concentration so local therapy has become an attractive adjunct to surgery. This study presents the mid- long-term results of local therapy with gentamicin in a bioabsorbable ceramic carrier. Method. A prospective series of 100 patients with Cierny & Mader Types III and IV cOM, affecting 105 bones, were treated with a single stage procedure, including debridement, deep tissue sampling, local and systemic antimicrobials, stabilization and immediate skin closure. cOM was confirmed with strict diagnostic criteria. Patients were followed up for a mean of 6.05 years (range 4.2–8.4 years). Results. At final follow-up, 6 patients had evidence of recurrent infection (94% infection-free). 3 infections recurred in the first year, with 2 in the second year and one at 4.5 years after surgery. Recurrence was not dependent on host physiological class (1/20 Class A; 5% vs 5/80 Class B; 6.25%. p=0.833). Nor was it related to aetiology of the infection, microbial culture or the presence of an infected non-union before surgery (1/10 with non-union; 10% vs 5/90 without non-union; 5.6%. p=0.57). Organisms which demonstrated intermediate or high-grade resistance to gentamicin were more likely in polymicrobial infections (9/21; 42.8%) compared to single isolate osteomyelitis (7/79; 8.9%)(p<0.001). However, recurrence was not more frequent when a resistant organism was present (1/16; 6.25% for resistant cases vs 5/84; 5.95% in sensitive culture infection) (p=0.96). Conclusions. This study shows that the single stage protocol, including a high delivery local antibiotic ceramic, was effective over several years. The method can be applied to a wide range of patients, including those with significant comorbidities and infected non-union


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 138 - 138
1 Mar 2012
Boden R Burgess E Enion D Srinivasan M
Full Access

Background. Successful use of bioabsorbable anchors for capsulolabral and rotator cuff repair is well documented. The bioknotless anchor (DePuy mitek) has demonstrated reliable fixation of these pathologies. However, this poly (L-lactide) polymer has recently demonstrated some similar complications to those documented for the earlier polyglycolic acid implants; namely synovitis and chondral damage with osteolysis. We report three cases with osteolysis and chondral damage associated with bioknotless anchors. Methods. A prospective record of shoulder arthroscopy is maintained by the senior author. From this, three patients with post-operative complications of arthropathy and osteolysis, following bioabsorbable anchor repair of capsulolabral lesions were identified. A retrospective review of case notes, radiographs, operative records and intraoperative video and photographic material was undertaken. Results. All patients had acceptable initial progress of rehabilitation. At 12-15 months, recurrence of symptoms promoted further radiological investigation and where the patient consented, repeat arthroscopy. In all cases advanced arthropathy was noted. Conclusion. It is likely that the use of knotless bioabsorbable anchors may promote advanced arthropathy. Initial loss of fixation and early pullout of the anchors may allow synovial contact with anchor material promoting hydrolysis and early arthropathy


Purpose. To evaluate the results of quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with four fold Hamstring Tendon Graft using Transfix and Bioabsorbable Interference Screw Fixation. Study Design. Retrospective review. Methods. Sixty-five patients (66 knees) were retrospectively identified by chart review as having undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction, with four fold Hamstring Tendon Graft, using Transfix and Bioabsorbable Interference Screw Fixation. All patients underwent a minimum two-year follow-up. Results. Data were collected on 48 knees in 47 patients (73%) at an average 30.2 months (range 24 to 43) after surgery. Thirty-six patients (37 knees) returned for clinical evaluation (56% return) and subjective follow-up only was obtained in 11 patients (17%). The mean Lysolm knee score was 91 (range, 45 to 98), with a mean of 97 for the uninvolved knee. The mean Tegner activity score was 5.7 (range 3 to 7). The KT-1000 arthrometer mean side-to-side difference for manual maximum displacement was 2.03 mm (range -1 to 8). The mean International Knee Documentation Committee knee score was 83 (range 47 to 100). Patients who underwent associated partial meniscectomy or meniscal repair had significantly lower International Knee Documentation Committee scores than patients without associated procedures (P < 0.01). Conclusions. Quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation is comparable with other methods of anterior cruciate ligament reconstruction in terms of patient satisfaction, knee stability, and function


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 50 - 50
1 Sep 2012
Roche A Selvaratnam V Mukhopadhaya S Unnikrishnan N Abiddin Z Narayan B Giotakis N Aniq H Nayagam S
Full Access

Introduction. The treatment of chronic osteomyelitis involves a debridement of affected non-viable tissue and the use of antibiotics. Where surgery leaves a cavity, dead space management is practised with antibiotic impregnated cement. These depots of local antibiotics are variable in elution properties and need removal. We review the use of bioabsorbable synthetic calcium sulphate as a carrier of gentamicin and as an adjunct in treating intramedullary osteomyelitis. Methods. A retrospective review of cases treated consecutively from 2006 to 2010 was undertaken. Variables recorded included aetiology, previous interventions, diagnostic criteria, radiological features, serology and microbiology. The Cierney-Mader system was used to classify. Treatment involved removal of implants (if any), intramedullary debridement and local resection (if needed), lavage and instillation of the gentamicin carrier, supplemented with systemic antibiotics. Follow-up involved a survival analysis to time to recurrence, clinical and functional assessment (AOFAS-Ankle/IOWA knee/Oxford Hip) and general health outcome (SF36). Results. There were 31 patients (22 male, 9 female). The mean age was 47 years (20–67). Twenty-five cases were post-surgery (6 open fractures) and 6 were haematogenous in origin. The median duration of osteomyelitis was 1.6yrs. The bones affected were 42% femur, 45% tibia, 3% radius and 10% humerus. 11 cases had diffuse as well as intramedullary involvement. 9 cases underwent segment resection and bone transport. We identified Staph. Aureus in 16 and Coag. Neg. Staph. in 6 cases. The median follow-up was 1.7 years (0.5–5.6). The median scores attained were: AOFAS-78, DASH-32, IOWA-71, Oxford-32. There were two recurrences. Discussion. Dead space management of intramedullary infections is difficult. We describe a method for delivery of local antibiotics and provide early evidence to its efficacy. The treatment success to date is 93%. Conclusion. Bioabsorbable carriers of antibiotics are efficacious adjuncts to surgical treatment of intramedullary osteomyelitis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 148 - 148
1 Sep 2012
Chukwunyerenwa C Murphy T Connolly P McCormack D
Full Access

Innominate Osteotomy first described by Salter is one of the commonest procedures performed for treatment of Developmental Dysplasia of the Hip (DDH) in children. We recently described a less invasive technique for Innominate Osteotomy, which significantly reduces the operation time without compromising outcome (J Pediatr Orthop B. 2010 Jul;19(4):318–22). As part of the evolution of this procedure we now routinely use bioabsorbable pins (INION OTPS PIN, made from co-polymers of L-lactic acid, D-lactic acid and trimethylene carbonate) instead of K-wires to secure the graft. We prospectively followed-up 120 consecutive cases done using bioabsorbale pins over a 2 year period. The surgical technique was as described in our less invasive innominate osteotomy paper. Average age at surgery was 24 months (18–52) with mean follow-up period of 15 months (6–24 months). The mean preoperative acetabular index was 36.2. o. Our results show a mean acetabular index of 18.7. o. (P< 0.0001) at latest follow-up with no loss of correction. We recorded three superficial wound infections (one MRSA), all resolved uneventfully. There was no foreign body reaction. The use of bioabsorbable pins eliminates the need for a second anaesthetic to remove the pins with significant cost benefit without compromising outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 17 - 17
1 Jul 2012
Roche A Selvaratnam V Mukhopadhaya S Unnikrishnan N Abiddin Z Narayan B Giotakis N Aniq H Nayagam S
Full Access

The treatment of chronic osteomyelitis involves a debridement of affected non-viable tissue and the use of antibiotics. Where surgery leaves a cavity, dead space management is practised with antibiotic impregnated cement. These depots of local antibiotics are variable in elution properties and need removal. We review the use of bioabsorbable synthetic calcium sulphate as a carrier of gentamicin and as an adjunct in treating intramedullary osteomyelitis. A retrospective review of cases treated consecutively from 2006 to 2010 in the Royal Liverpool University Hospital was undertaken. Variables recorded included aetiology, previous interventions, diagnostic criteria, radiological features, serology and microbiology. The Cierney-Mader system was used to classify. Treatment involved removal of implants (if any), intramedullary debridement and local resection (if needed), lavage and instillation of the gentamicin carrier, supplemented with systemic antibiotics. Follow-up involved a survival analysis to time to recurrence, clinical and functional assessment (AOFAS-Ankle/IOWA knee/Oxford Hip) and general health outcome (SF36). There were 31 patients (22 male, 9 female). The mean age was 47 years (20-67). Twenty-five cases were post-surgery (6 open fractures) and 6 were haematogenous in origin. The median duration of osteomyelitis was 1.6yrs. The bones affected were 42% femur, 45% tibia, 3% radius and 10% humerus. 11 cases had diffuse as well as intramedullary involvement. 9 cases underwent segment resection and bone transport. We identified Staphylococcus Aureus in 16 and Coagulase Negative Staphylococcus in 6 cases. The median follow-up was 1.7 years (0.5-5.6). The median scores attained were: AOFAS-78, DASH-32, IOWA-71, Oxford-32. There were two recurrences. Dead space management of intramedullary infections is difficult. We describe a method for delivery of local antibiotics and provide early evidence to its efficacy. The treatment success to date is 93%. Bioabsorbable carriers of antibiotics are efficacious adjuncts to surgical treatment of intramedullary osteomyelitis


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 52 - 52
1 Dec 2018
Ferguson J Athanasou N McNally M
Full Access

Aim

This study describes the histologic changes seen with a gentamicin-eluting synthetic bone graft substitute (BGS)(1) in managing bone defects after resection of chronic osteomyelitis (cOM).

Method

154 patients with mean follow-up of 21.8 months (12–56) underwent treatment of cOM with an antibiotic-loaded BGS for defect filling.

Nine patients had subsequent surgery, not related to infection recurrence, allowing biopsy of the implanted material. These biopsies were harvested between 19 days and two years after implantation, allowing a description of the material's remodelling over time. Samples were fixed in formalin and stained with haematoxylin-eosin. Immunohistochemistry, using an indirect immunoperoxidase technique, identified the osteocyte markers Dentine Matrix Protein-1 (DMP-1) and Podoplanin, the macrophage/osteoclast marker CD68, and the macrophage marker CD14.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 21 - 21
1 Dec 2015
Mcnally M Ferguson J Kendall J Dudareva M Scarborough M Stubbs D
Full Access

To evaluate the clinical outcome of three different local antibiotic delivery materials, used as bone defect fillers after excision of chronic osteomyelitis.

We reviewed all patients receiving Collagen Fleece with Gentamicin (Septocoll E)(n=74), Calcium Sulphate with Tobramycin pellets (Osteoset T)(n=166) or Calcium Sulphate/Hydroxyapatite biocomposite with Gentamicin (Cerament G)(n=73) for dead space filling after resection of C-M Stage III and IV chronic osteomyelitis. Data was collected on patient comorbidities, operation details, microbiology, postop complications and need for plastic surgery or external fixation. All operations were performed by two surgeons. All patients had similar systemic antibiotic therapy and rehabilitation.

Primary outcomes were recurrence rate, fracture rate and wound leakage rate.

All three groups had very similar mean age and range, microbiological cultures, need for free muscle flaps or local flaps, proportion of femur, tibia and upper limb bones and use of external fixation. There were small differences in the proportion of C-M Class B hosts and anatomic Type IV cases, between the groups. All patients were followed up for at least one year. Mean follow-up was 1.75 years for Septocoll E, 1.96 years for Osteoset T and 1.78 years for Cerament G.

After surgery, there were fewer prolonged wound leaks with Cerament G (leakage persisting for more than 2 weeks). Fracture rates and infection recurrence were twice as common with Osteoset T compared with Cerament G at between one and two years after operation (see Table).

The use of a biocomposite material delivering local aminoglycoside was associated with lower recurrence rates and few wound problems, compared with collagen or calcium sulphate alone. This may reflect the higher levels of antibiotic in the defect and controlled release profile. The improved recurrence rate was despite a higher percentage of compromised Class B hosts.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 105 - 105
1 Sep 2012
Pinczewski L Gordon D Sri-Ram K Kok A Linklater J Salmon L
Full Access

Bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been shown to be associated with femoral tunnel widening and cyst formation.

To compare a poly-L-lactide–hydroxyapatite screw (PLLA-HA) with a titanium screw with respect to clinical and radiological outcomes over a 5 year period.

40 patients were equally randomized into 2 groups (PLLA-HA vs titanium) and ACLR performed with a 4 strand hamstring graft with femoral tunnel drilling via the anteromedial portal. Evaluation at 2 and 5 years was performed using the International Knee Documentation Committee assessment (IKDC), Lysholm knee score, KT 1000 arthrometer, single-legged hop test. Magnetic resonance imaging was used to evaluate tunnel and screw volume, ossification around the screws, graft integration and cyst formation.

There was no difference in any clinical outcome measure at 2 or 5 years between the 2 groups. At 2 years, the PLLA-HA femoral tunnel was significantly smaller than the titanium screw tunnel (p=0.015) and at 5 years, there was no difference. At 2 years the femoral PLLA-HA screw was a mean 76% of its original volume and by 5 years, 36%. At 2 years the tibial PLLA-HA screw mean volume was 68% of its original volume and by 5 years, 46%. At 5 years, 88% of femoral tunnels and 56% of tibial tunnels demonstrated a significant ossification response. There was no increase in cyst formation in the PLLA-HA group and no screw breakages.

The PLLA-HA screw provides adequate aperture fixation in ACLR with excellent functional outcomes. It was not associated with femoral tunnel widening or increased cyst formation when compared with the titanium screw. The resorbtion characteristics appear favourable and the hydroxyapatite component of the screw may stimulate osteoconduction, contributing to these results. The PLLA-HA screw is a good alternative to a titanium screw in ACLR, which may aid revision procedures and allow for imaging without artifact.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 143 - 143
1 Mar 2012
Chidambaram R Mok D
Full Access

Introduction. Unstable dorsal fracture/dislocation of PIP joint is a complex injury and difficult to treat. Different treatment methods have been described with varying results. We describe a novel technique to combine fracture fixation with volar plate repair using micro anchor suture. Material and methods. Between July and December 2005, 11 consecutive patients with unstable dorsal PIP joint dislocations underwent open reduction and volar plate repair using our technique. Nine patients had dorsal fracture dislocations and two had open dislocations. All patients were males and their average age was 26 years. All patients were reviewed with the minimum follow up of 12 months. The pain score, range of movements and grip strength were recorded and compared to the normal side. Operative Technique. Volar approach was made using a semi Brunar incision. One or two micro bioabsorbable anchors (Mitek, Ethicon Ltd, UK) were used to stabilise the joint and repair the volar plate. Additional anchor was used to repair the collateral ligament when indicated. Post-operatively the hand was rested in Edinburgh functional splint for 10 days followed by active and assisted range of movements under hand physiotherapist supervision. Results. 10 out 11 patients had excellent pain relief. The average range of movement of the PIP joint was 100 degrees. One patient with neglected PIP joint fracture dislocation for 10 weeks had mild residual pain and stiffness. The mean grip strength was 87% of that of contralateral normal side. All patients returned to their same work as before. 8 out of 9 patients returned to play their regular sports at the same level. All patients were satisfied with the functional outcome. Conclusion. Combined fracture fixation and volar plate repair through anterior approach using micro bioabsorbable anchors appears to be very effective way of treating this otherwise complex unstable fracture/dislocation of PIP joint


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1289 - 1296
1 Sep 2016
McNally MA Ferguson JY Lau ACK Diefenbeck M Scarborough M Ramsden AJ Atkins BL

Aims

Chronic osteomyelitis may recur if dead space management, after excision of infected bone, is inadequate. This study describes the results of a strategy for the management of deep bone infection and evaluates a new antibiotic-loaded biocomposite in the eradication of infection from bone defects.

Patients and Methods

We report a prospective study of 100 patients with chronic osteomyelitis, in 105 bones. Osteomyelitis followed injury or surgery in 81 patients. Nine had concomitant septic arthritis. 80 patients had comorbidities (Cierny-Mader (C-M) Class B hosts). Ten had infected nonunions.

All patients were treated by a multidisciplinary team with a single-stage protocol including debridement, multiple sampling, culture-specific systemic antibiotics, stabilisation, dead space filling with the biocomposite and primary skin closure.


Bone & Joint Research
Vol. 3, Issue 6 | Pages 193 - 202
1 Jun 2014
Hast MW Zuskov A Soslowsky LJ

Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing.

Cite this article: Bone Joint Res 2014;3:193–202.