Advertisement for orthosearch.org.uk
Results 1 - 20 of 177
Results per page:
Bone & Joint Research
Vol. 1, Issue 10 | Pages 234 - 237
1 Oct 2012
Hughes AW Dwyer AJ Govindaswamy R Lankester B

Objectives. Our aim was to assess the use of intra-operative fluoroscopy in the assessment of the position of the tibial tunnel during reconstruction of the anterior cruciate ligament (ACL). Methods. Between January and June 2009 a total of 31 arthroscopic hamstring ACL reconstructions were performed. Intra-operative fluoroscopy was introduced (when available) to verify the position of the guidewire before tunnel reaming. It was only available for use in 20 cases, due to other demands on the radiology department. The tourniquet times were compared between the two groups and all cases where radiological images lead to re-positioning of the guide wire were recorded. The secondary outcome involved assessing the tibial interference screw position measured on post-operative radiographs and comparing with the known tunnel position as shown on intra-operative fluoroscopic images. Results. Of the 20 patients treated with fluoroscopy, the imaging led to repositioning of the tibial guide wire before reaming in three (15%). The mean tourniquet time with intra-operative fluoroscopy was 56 minutes (44 to 70) compared with 51 minutes (42 to 67) for the operations performed without. Six patients (30%) had post-operative screw positions that were > 5% more posterior than the known position of the tibial tunnel. Conclusion. Intra-operative fluoroscopy can be effectively used to improve the accuracy of tibial tunnel positions with minimal increase in tourniquet time. This study also demonstrates the potential inaccuracy associated with plain radiological assessment of tunnel position


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 43 - 47
1 Jan 2004
Ritter MA Faris PM Thong AE Davis KE Meding JB Berend ME

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA. We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Pre-operative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intra-operative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7° were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7° of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 475 - 480
1 Apr 2009
Matsumoto T Kuroda R Kubo S Muratsu H Mizuno K Kurosaka M

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0°, 10°, 45°, 90° and 135° of flexion, with the patella both everted and reduced. While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p < 0.05)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 71 - 71
1 Mar 2012
Hughes AW Dwyer AJ Govindaswamy R Lankester BJA
Full Access

The outcome following arthroscopic anterior cruciate (ACL) reconstruction is dependant on a combination of surgical and non-surgical factors. Technical error is the commonest cause for graft failure, with poor tunnel placement accounting for over 80% of those errors. A routine audit of femoral and tibial tunnel positions following single bundle hamstring arthroscopic ACL reconstruction identified apparent inconsistent positioning of the tibial tunnel in the sagittal plane. Intra-operative fluoroscopy was therefore introduced (when available) to verify tibial guide wire position prior to tunnel reaming. This paper reports a comparison of tibial interference screw position measured on post-operative radiographs with known tunnel position as shown on intra-operative fluoroscopic images in 20 patients undergoing routine primary ACL reconstruction between January and June 2009. Surgery took a mean of 5 minutes longer when intra-operative fluoroscopy was used. In 3/20 patients, fluoroscopy led to re-positioning of the tibial guide wire prior to tunnel reaming. The mean tibial tunnel position as indicated by the tunnel reamer was 41 +/− 2.7 % of the total plateau depth (range 37% to 47%). The mean position projected from the tibial screw on post operative radiographs was 46 +/− 9.2% (range 38% to 76%). A paired t-test showed a significant difference (p = 0.022) between true tunnel position and tibial screw position. 6/20 patients had post operative screw positions that were > 5% more posterior than the known position of the tibial tunnel. The position of the tunnel should be measured at its mid-point where this is evident. On most early radiographic images, the margins of the tunnel are not clear and therefore a line projected from the centre of the screw is used. This audit demonstrates the potential inaccuracy associated with this


Bone & Joint Research
Vol. 5, Issue 7 | Pages 280 - 286
1 Jul 2016
Ozkurt B Sen T Cankaya D Kendir S Basarır K Tabak Y

Objectives. The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty. Methods. The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, . sd. 9.4; 34 to 69). The ratios of the DMAD, PMAD, DLAD and PLAD to TEW were calculated. Results. The mean TEW, DMAD, PMAD, DLAD and PLAD were 82.76 mm (standard deviation (. sd. ) 7.74), 28.95 mm (. sd. 3.3), 28.57 mm (. sd. 3), 23.97 mm (. sd. 3.27) and 24.42 mm (. sd. 3.14), respectively. The ratios between the TEW and the articular distances (DMAD/TEW, DLAD/TEW, PMAD/TEW and PLAD/TEW) were calculated and their means were 0.35 (. sd. 0.02), 0.34 (. sd. 0.02), 0.28 (. sd. 0.03) and 0.29 (. sd. 0.03), respectively. Conclusion. This method provides a simple, reproducible and reliable technique enabling accurate anatomical joint line restoration during revision total knee arthroplasty. Cite this article: B. Ozkurt, T. Sen, D. Cankaya, S. Kendir, K. Basarır, Y. Tabak. The medial and lateral epicondyle as a reliable landmark for intra-operative joint line determination in revision knee arthroplasty. Bone Joint Res 2016;5:280–286. DOI: 10.1302/2046-3758.57.BJR-2016-0002.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 638 - 641
1 May 2012
Ha C Na S

We aimed to obtain anthropometric data on Korean knees and to compare these with data on commonly available total knee arthroplasties (TKAs). The dimensions of the femora and tibiae of 1168 knees were measured intra-operatively. The femoral components were found to show a tendency toward mediolateral (ML) under-coverage in small femurs and ML overhang in the large femurs. The ML under-coverage was most prominent for the small prostheses. The ML/anteroposterior (ML/AP) ratio of Korean tibiae was greater than that of tibial components.

This study shows that, for different reasons, current TKAs do not provide a reasonable fit for small or large Korean knees, and that the ‘gender-specific’ and ‘stature-specific’ components help for large Korean femurs but offer less satisfactory fits for small femurs. Specific modifications of prostheses are needed for Asian knees.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 67 - 67
1 Jul 2022
Bhamber N Chaudhary A Middleton S Walmsley K Nelson A Powell R Mandalia V
Full Access

Abstract. Introduction. High posterior tibial slope (PTS) has been recognised as a risk factor for anterior cruciate ligament rupture and graft failure. This prospective randomised study looked at intra-operative findings of concomitant intra-articular meniscal and chondral injuries during a planned ACL reconstruction. Material and Methods. Prospective data was collected as part of a randomised trial for ACL reconstruction techniques. Intra-operative data was collected and these findings were compared with the PTS measured on plain radiograph by a single person twice through a standardised technique and intra-observer analysis was performed. Results. 49 confirmed ACL rupture patients were in the trial. The average age was 34 (23–66) years and 12 patients were female. 17 patients (34%) had PTS of 12 degrees or more. The intra-observer analysis for PTS measurements in a 2-sided paired T test, showed a mean difference of 0.03 degrees with a P value = 0.83. 23 patients had medial meniscal pathology identified, 15 (65%) had a PTS <12 degrees. 16 patients had lateral meniscus pathology and 9 (56%) had a PTS <12 degrees. Chondral damage did not appear significantly different in the two groups (<12 degrees 15% vs >12 degrees 23%). Conclusion. In this sample, a PTS >12 degrees was not associated with a higher incidence of meniscal or chondral damage after a confirmed ACL rupture


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 30 - 30
7 Aug 2023
Mayne A Rajgor H Munasinghe C Agrawal Y Pagkalos I Davis E Sharma A
Full Access

Abstract. Introduction. There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty - The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using intra-operative bony registration). The Mako knee system is an image-based system (using a pre-operative CT scan). This study aimed to compare surgical accuracy between the ROSA and Mako systems with specific reference to Joint Line Height, Patella Height and Posterior Condylar Offset. Methodology. This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive ROSA TKAs and the initial 50 consecutive Mako TKAs performed by two high volume surgeons. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph. Patella height was assessed using the Insall-Salvati ratio. Results. There was no significant difference between ROSA TKA and Mako TKA with regards to restoration of joint line height, ROSA mean 0.2mm versus Mako mean 0.3mm (p<0.05), posterior condylar offset, ROSA mean 0.16mm versus Mako mean 0.3mm (p<0.05), and patella height, ROSA mean 0.02 versus Mako mean 0.03 (p<0.05). Conclusion. This study is the first study to compare the accuracy of the ROSA and MAKO knee systems in total knee arthroplasty. Both systems are highly accurate in restoring native posterior condylar offset, joint line height, and patella height in TKA with no significant difference demonstrated between the two robotic systems


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract. Introduction. Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. Methodology. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed. Results. Achondroplasia was the most common skeletal dysplasia (8), followed by Chondrodysplasia punctata (7) and Spondyloepiphyseal dysplasia (5). There were fourteen men and eight women with mean age of 51 years (28 to 73). The average height of patients was 1.4 metres (1.16–1.75) and the mean weight was 64.8 Kg (34.3–100). The mean follow up duration was 68.32 months (1–161). Three patients died during follow up. Custom implants were required in twelve patients (38.71%). Custom jigs were utilised in six patients and two patients underwent robotic assisted surgery. Hinged TKR was used in seventeen patients (54.84%), posterior stabilised TKR in nine patients (29.03%), and cruciate retaining TKR in five patients (16.13%). One patient underwent a patella resurfacing for persistent anterior knee pain and another had an intra-operative medial tibial plateau fracture which was managed with fixation. No revisions occurred during the follow up period. Conclusion. Despite the technical challenges and complexity of TKR within this unique patient group, we demonstrate good implant survivorship during the study period. Cross sectional imaging is recommended preoperatively for precise planning and templating


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 82 - 82
1 Jul 2022
Walker L Clement N Deehan D
Full Access

Abstract. Introduction. The prevalence of recurrent infection following two-stage exchange arthroplasty following failure of a total knee arthroplasty (TKA) has been reported to be 10% to 25%. There is limited literature available on repeat two stage revisions for TKA infection with only small cohorts and variable success rates. Methodology. A retrospective cohort study investigating the outcome of two stage revision arthroplasty for treatment of TKA infection was conducted with the aim of identifying factors linked to recurrence of infection. A consecutive cohort of all microbiology intra-operative periprosthetic knee samples from a single revision arthroplasty centre between January 2010 and December 2016 was identified. The final cohort consisted of 658 samples taken during 64 patients undergoing two stage revision knee surgery for infection. Patient demographics, medical and orthopaedic history data including post-operative outcomes and subsequent treatment was obtained from the electronic records system and medical notes. Results. 65.6% of the cohort (N=42) had successful eradication of their infection. For the twenty-two patients that had failure of their two stage revision, twenty patients had samples available from further surgical intervention. Sixteen patients (80%) had different organisms isolated when they had repeat surgical samples taken when compared to their first stage samples. Overall, for subsequent treatments there was a success rate of 75% if the same organism was identified and 62.5% if there were new isolated organisms. Conclusion. These findings may have implications for the treatment strategies chosen for re-infection after two stage TKA revisions if new causative organisms are isolated


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 71 - 71
1 Jul 2022
Santini A Jamal J Wong P Lane B Wood A Bou-Gharios G Frostick S Roebuck M
Full Access

Abstract. Introduction. Risk factors for osteoarthritis include raised BMI and female gender. Whether these two factors influenced synovial gene expression was investigated using a triangulation and modelling strategy which generated 12 datasets of gene expression in synovial tissue from three knee pathologies with matching BMI groups, obese and overweight, and gender distributions. Methodology. Intra-operative synovial biopsies were immersed in RNAlater at 4oC before storage at -80oC. Total RNA was extracted using RNAeasy with gDNA removal. Following RT- PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Linear models were prepared in limma with gender and BMI factors incorporated sequentially for each pathology comparison, generating 12 models of probes differentially expressed at FDR p<0.05 and Bayes number, B>0. Data analysis of differently expressed genes utilized Ingenuity Pathway Analysis and Cytoscape with Cluego and Cytohubba plug-ins. Results. Expression of 453 synovial genes was influenced by BMI and gender, 360 encode proteins such as HIF-1a, HSF1, HSPA4, HSPA5. Top canonical pathways include Unfolded protein response, Protein Ubiquiitation and Clathrin mediated endocytosis signalling linked by modulation of heat shock proteins, comparable to pathology dependent regulation. In addition BMI and gender modulate gene expression in the NRF2-mediated oxidative stress response pathway with down regulation of Glutathione-S-transferases potentially down regulating antioxidant defences. Conclusion. The enhanced risk of osteoarthritis induced by an elevated BMI and female gender maybe include differential expression of heat shock proteins and genes in the NRF2 pathway


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 98 - 98
1 Jul 2022
Vidakovic H Meen R Ohly N
Full Access

Abstract. Introduction. Mako robotic assisted knee arthroplasty requires a planning CT scan within 8 weeks of surgery according to the supplier's protocol. This is often impractical, therefore we evaluated whether CT scans remain valid for an extended period. Methodology. Patients undergoing Mako partial (PKA) and total (TKA) knee arthroplasty were identified from our hospital database. The hospital PACS system was used to define the time interval between the initial planning CT scan and surgery, and whether further imaging was required prior to surgery. Results. 443 consecutive Mako cases (225 TKA and 218 PKA) were undertaken between November 2019 and December 2021 (33 cases to March 2020, and 410 cases from August 2020). CT scans were done within 8 weeks of surgery in 229 patients (51.7%); between 8 and 24 weeks in 148 patients (33.4%); between 24 and 48 weeks in 53 patients (12.0%); and more than 48 weeks in 13 patients (2.9%). Repeat pre-operative radiographs were done in the first 43 patients with a delay to surgery of more than 8 weeks following their CT scan. No gross anatomical changes were identified, and this practice was therefore discontinued. No patients required a repeat CT scan. There were no intra-operative registration errors in any patient in this series. Conclusion. Planning CT scans were valid for up to one year in a large series of patients undergoing Mako PKA and TKA. This may allow for more cost-effective use of resources, while minimising irradiation to patients


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 70 - 70
1 Jul 2022
Wong P Jamal J Santini A Lane B Wood A Bou-Gharios G Frostick S Roebuck M
Full Access

Abstract. Introduction. Synovitis impacts osteoarthritis symptomatology and progression. The transcription factors controlling synovial gene expression have not been described. This study analyses gene expression in synovium samples from 16 patients with osteoarthritis with 9 undergoing arthroscopic and 8 knee trauma surgery for non-arthritic pathologies. Methodology. Intra-operative synovial biopsies were immersed in RNAlater at 4oC before storage at -80oC. Total RNA was extracted using RNAeasy. After purification, RT-PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Linear models were prepared in limma with gender and BMI factors incorporated sequentially for each pathology comparison, generating 12 models of probes differentially expressed at FDR p<0.05 and Bayes number, B>0. Data analysis of differently expressed genes utilized Ingenuity Pathway Analysis and Cytoscape with Cluego and Cytohubba plug-ins. Results. Amongst the 2084 genes with significantly differential expression (DEG), 135 had transcription regulator capabilities and 121 a nuclear location. IPA analysis of OATKR and arthroscopic tissue comparison DEG identified 12 nuclear transcription factors linked to 31 DEG whose encoded proteins located within cytoplasmic and cell membrane compartments. All 12 were significantly up-regulated and acting in pathways up-regulating transcription of DNA and RNA, cell survival and angiogenesis while down-regulating senescence and apoptosis. NFE2L2, integral to the TGF-beta signalling pathway, was identified as a bottleneck gene. Conclusion. This analysis indicates the complexity of synovial gene expression regulation and offers target genes and pathways for evaluation during osteoarthritis pathogenesis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 48 - 48
1 Jul 2022
Blucher N Fletcher J Platt N Porteous A
Full Access

Abstract. Introduction. Controversy exists regarding the optimal tibial coronal alignment in total knee arthroplasty. Many believe navigation or robotics are required to set kinematic alignments or to ensure they remain within ‘safe’ limits e.g. maximum 5° varus on the tibia. Given most navigation or robotic systems require the surgeon to identify the ankle malleoli, this study aimed to radiographically analyse standardly used intra-operative landmarks around the ankle, assessing their value in achieving kinematic alignment / setting safety boundaries. Materials and Methods. Long leg alignment radiographs were analysed independently by two orthopaedic surgeons at two time points, eight weeks apart. Angles were measured between the long axis of the tibia (TB) and: 1. lateral malleolus (TB-LM), 2. lateral border of the talus (TB-LT) and 3. medial aspect of the medial malleolus (TB-MM). Intra- and inter-rater reliabilities were assessed. Results. One hundred and sixty-seven radiographs in 119 patients were analysed; mean age 71.6 years. Mean angles (95% CI) were: TB-LM 4.8° (4.7°- 4.8°), TB-LT 2.6° (2.5° - 2.6°) and TB-MM 4.2° (4.1° - 4.2°). Interrater reliability was good for TB-LM (ICC = 0.72) and TB-MM (ICC=0.67), and fair for TB-LT (ICC= 0.50). Intra-rater reliability was excellent for all measures (ICC >0.85). Conclusion. There are consistent angles between tibial alignment and ankle landmarks. Using these landmarks, with standard instrumentation and alignment checks, allows surgeons to define safe limits, e.g. maximum 4.8° tibial varus if aligned to the tip of the lateral malleolus or set a 2.5° varus cut, without the need for added technology


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 34 - 34
1 Oct 2020
Mahfouz MR
Full Access

Introduction. The objective of this study is to assess the use of ultrasound (US) as a radiation free imaging modality to reconstruct three-dimensional knee anatomy. Methods. An OEM US system is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allowing for 3D tracking of probe and femur and tibia. The raw US RF signals are acquired and using real time signal processing, bone boundaries are extracted. Bone boundaries are then combined with the EM sensor information in a 3D point cloud for both femur and tibia. Using a statistical shape model, the patient specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was then conducted for 11 cadavers by comparing the 3D US models to those created using CT scans. Results. The results revealed the US bone models were accurate compared to the CT models (Mean RMS: femur: 1.03±0.15 mm, tibia:1.11± 0.13). Also, femoral landmarking proved to be accurate (transepicondylar axis: 1.07±0.65°, Posterior condylar axis: 0.73±0.41° Distal condylar axis: 1.12±0.89°, Medial AP: 1.39±1.18 mm, Lateral AP: 1.56±1.15 mm, TEA width: 1.2±0.87 mm). Tibial landmarking errors were slightly higher (Posterior slope axis: 2 ±1.19° and Tubercle axis: 1.8±1.37°). The models were then used to evaluate implant sizing as, 90% of the femurs and 60% of the tibias were sized correctly, while the others were off only one size. Discussion. The 3D US bone models were proven to be accurate compared to CT and can be used for preoperative planning. 3D ultrasound is radiation free and offers numerous clinical opportunities for bone creation in minutes during their office visit, surgeon-patient pre-operative planning, implant sizing and selection, 3D dynamic ligament balancing and intra-operative registration for use with robots and navigation systems


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 28 - 28
1 Oct 2020
Deckey DG Rosenow CS Verhey JT Mayfield CK Christopher ZK Clarke HD Bingham JS
Full Access

Introduction. Robot-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to quantify soft tissue laxity and adjust the plan prior to bone resection should reduce variability in polyethylene thickness. This study was performed to compare accuracy to plan for component positioning and polyethylene thickness in RA-TKA versus M-TKA. Methods. 199 consecutive primary TKAs (96 C-TKA and 103 RA-TKA) performed by a single surgeon were reviewed. Full-length standing and knee radiographs were obtained pre and post-operatively. For M-TKA, measured resection technique was used. Planned coronal plane femoral and tibial component alignment, and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9mm. For RA-TKA, individual component position was adjusted to assist balance the gaps but planned coronal plane alignment for the femoral and tibial components and overall limb alignment had to remain 0+/− 3°; planned tibial posterior slope was 1.5°. Planned values and polyethylene thickness for RA-TKA were obtained from the final intra-operative plan. Mean deviations from plan for each parameter were compared between groups (ΔFemur, ΔTibia, ΔPS, and polyethylene thickness) as were distal femoral recut and tourniquet time. Results. In RA-MKA versus M-TKA: the ΔFemur (0.9 ° v. 1.7 °), ΔTibia (0.3 ° v. 1.3 °), and ΔPS (−0.3 ° v. 1.7 °) all deviated significantly less from plan (all p<0.0001); significantly fewer knees required distal femoral recut (10% vs. 23%, p=0.033); and deviation from planned polyethylene thickness was significantly less (1.4mm vs 2.7mm, p<0.0001. However, tourniquet time was longer (99 minutes v. 89 minutes, p<0.0001). Conclusion. RA-TKA is both significantly more accurate to plan for component positioning and final polyethylene thickness. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 3 - 3
1 Oct 2018
Catani F Zambianchi F Marcovigi A Franceschi G Nardacchione R
Full Access

Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated the reliability of robotic assisted UKA over manual UKA in component placement and executing a soft-tissue tensioning plan. The purpose of this multicenter study was to determine the correlation between 3D component positioning and soft-tissue tensioning with short-term clinical results following robotic assisted medial UKA. Methods. Between 2013 and 2016, 349 patients (381 knees) underwent robotic assisted fixed bearing metal backed medial UKAs at two centres. Follow-up was performed at 12 months minimum. Pre- and post-operatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS), Forgotten Joint Score 12 (FJS), and Short-Form summary scale (SF-12) surveys. Clinical results for every score were stratified as ‘excellent’, ‘mild’ and ‘insufficient’. Post-operative complications were recorded. Failure mechanisms, reoperations and post-operative knee pain were also assessed. Intra-operative robotic data relative to femoral and tibial component placement in the coronal, sagittal and horizontal plane, as well as femoro-tibial gaps at different knee flexion angles were also collected. Results. A total of 338 robotic assisted medial UKAs (309 patients) were assessed at an average follow-up of 33.5 months post-operatively (89% follow-up rate). Three implants were revised, resulting in a survivorship of 99.0% (C.I. 97.0%–99.7%), one for prosthetic joint infection and two for tibial aseptic loosening. All clinical post-operative scores were significantly improved from the pre-operative scores. The following statistically significant correlations were found between intra-operative robotic data and outcomes considered individually: femoral component coronal alignment influenced KOOS Symptoms, Pain and Quality of Life (p<0.05), sagittal alignment influenced KOOS Symptoms and Pain (p<0.05), and femoro-tibial gaps at 20°–30° knee flexion influenced KOOS Pain and Function in Activities of Daily Living (p<0.05). Both, tibial sagittal alignment and femoro-tibial gaps at 80°–90° knee flexion were found to correlate with SF-12 Physical Status and presence of post-operative pain (p<0.01). ‘Excellent’ clinical outcomes were reported by those patients who, on average, had the femur placed in neutral alignment in the coronal and horizontal planes (0.2°±1.5 and 0.6°±1.4 respectively) as well as avoided excessive flexion in the sagittal plane (3.7°±3.2). When considering the tibia, better results were reported by patients with the tibial component placed in slight external rotation (2.2°±1.7), varus coronal alignment (1.5°±1.7) and no more than 5° of posterior slope (5.0°±1.0). Regarding femoro-tibial gaps, ‘excellent’ clinical outcomes were reported by patients who were slightly loose between 20°–30° and 80°–90° of knee flexion. Conclusion. In the present study, survivorship and clinical outcomes of a large cohort of 309 patients with medial robotic assisted UKA were contacted with at a mean 3-years. The overall survivorship was found to be 99%, with tibial component failure as the most common reason for UKA revision. The significant difference between pre- and post-operative clinical scores highlights the efficacy of robotic assisted UKA in restoring knee function and relieving pain. Differences in components’ positioning and soft-tissue tensioning demonstrated significant correlation with post-operative clinical outcomes


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1319 - 1328
1 Oct 2017
Shelton TJ Nedopil AJ Howell SM Hull ML

Aims. The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces. Patients and Methods. The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria. Results. The proportion of patients with outlier varus or valgus alignment was 16%/24% for the HKA angle, 55%/0% for the PMTA, 0%/57% for the DLFA, 25%/12% for the TFA, 100%/0% for the TCA, and 0%/64% for the FCA. In general, the forces in the medial and lateral compartments of those with outlier alignment were not different from those with in-range alignment except for the TFA, in which patients with outlier varus alignment had a mean paradoxical force which was 6 lb higher in the lateral compartment than those with in-range alignment. None of the measurements of alignment of the limb, knee and components predicted the force in the medial or lateral compartment. Conclusion. Although kinematically aligned TKA has a high proportion of varus or valgus outliers using mechanically aligned criteria, the intra-operative forces in the medial and lateral compartments of patients with outlier alignment were comparable with those with in-range alignment, with no evidence of overload of the medial or lateral compartment of the knee. Cite this article: Bone Joint J 2017;99-B:1319–28


Bone & Joint Research
Vol. 6, Issue 9 | Pages 535 - 541
1 Sep 2017
Zan P Mol MO Yao JJ Fan L Yang D Liu K Li G

Objectives. The length of the tourniquet time during total knee arthroplasty (TKA) is related to the incidence of post-operative deep vein thrombosis (DVT). Our aim in this study was to investigate the effect of the early release of the tourniquet on the incidence of DVT in patients undergoing TKA. Methods. A total of 200 patients who underwent TKA between November 2015 and November 2016 were prospectively enrolled. The tourniquet was inflated before surgery and released immediately after the introduction of the components (early release group). This group was compared with a retrospective cohort of 200 primary TKAs, in which the tourniquet was released after the dressings had been applied (late release group). The presence of a DVT was detected using bilateral lower limb ultrasonography. Peri-operative clinical and follow-up data were collected for analysis. Results. The incidence of DVT in the early release group (9 of 196, 4.6%) was significantly lower compared with the late release group (24 of 200, 12%; odds ratio (OR) 0.35, 95% confidence interval (CI) 0.16 to 0.78, p = 0.008). The incidence of proximal DVT in the early release group (1 of 196 (0.5%)) was significantly lower than in the late release group (8 of 196, 4%; OR 0.12, 95% CI 0.02 to 0.99, p = 0.020). Although the mean intra-operative blood loss was higher in the early release group, the mean post-operative drainage, total blood loss, transfusion requirements and complications were not significantly different in the two groups. Conclusion. In patients who undergo TKA, releasing the tourniquet early is associated with a decreased incidence of DVT, without increasing the rate of complications. Cite this article: Bone Joint Res 2017;6:535–541


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 61 - 61
1 Oct 2019
Warth LC Deckard ER Meneghini RM
Full Access

Introduction. t is accepted dogma in total knee arthroplasty (TKA) that resecting the posterior cruciate ligament (PCL) increases the flexion space by approximately 4mm, which significantly affects intra-operative decisions and surgical techniques. Unfortunately, this doctrine is based on historical cadaveric studies of limited size. This study purpose was to more accurately determine the effect of PCL resection on the tibiofemoral flexion gap dimension in vivo in a large sample. Methods. Tibiofemoral joint space measurements were made during 127 standardized TKAs by two arthroplasty surgeons. A medial parapatellar approach, computer navigation and provisional tibial and femoral bone cuts were performed in all cases with particular attention to preserving PCL integrity. Cases with an incompetent or damaged PCL were excluded. The tibiofemoral gap dimension was measured with a calibrated tension device at full extension, 45-degrees, and 90-degrees before and after complete PCL resection. Results. 52% of patients were female (66/127), with mean age and BMI of 69.4 years and 34.3 kg/m. 2. , respectively. After PCL resection, the mean joint space dimension increased 0.3mm (range, 0–3mm) at extension, 0.9mm (range, 0–4mm) at 45-degrees, and 1.7mm (range, 0–5mm) at 90-degrees (p<0.001). The 90-degree flexion space opened ≤1mm in 48% of patients and ≥3mm in only 10%. Dividing the flexion gap change by the femoral implant dimension to account and calibrate for patient size, the joint space at 90-degrees increased more in females (0.031 vs. 0.023, p=0.022). Conclusion. The tibiofemoral joint space increases progressively from extension, to mid-flexion through 90-degrees flexion after PCL resection, yet is substantially less than reported in historical studies. However, large variation in the degree of flexion space opening was observed with some patients failing to increase their flexion space whatsoever with PCL resection. This runs counter to conventional TKA understanding and should be considered in modern surgical techniques and education. For figures, tables, or references, please contact authors directly