Objectives. Our aim was to assess the use of
Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared
We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the
The outcome following arthroscopic anterior cruciate (ACL) reconstruction is dependant on a combination of surgical and non-surgical factors. Technical error is the commonest cause for graft failure, with poor tunnel placement accounting for over 80% of those errors. A routine audit of femoral and tibial tunnel positions following single bundle hamstring arthroscopic ACL reconstruction identified apparent inconsistent positioning of the tibial tunnel in the sagittal plane.
Objectives. The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty. Methods. The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, . sd. 9.4; 34 to 69). The ratios of the DMAD, PMAD, DLAD and PLAD to TEW were calculated. Results. The mean TEW, DMAD, PMAD, DLAD and PLAD were 82.76 mm (standard deviation (. sd. ) 7.74), 28.95 mm (. sd. 3.3), 28.57 mm (. sd. 3), 23.97 mm (. sd. 3.27) and 24.42 mm (. sd. 3.14), respectively. The ratios between the TEW and the articular distances (DMAD/TEW, DLAD/TEW, PMAD/TEW and PLAD/TEW) were calculated and their means were 0.35 (. sd. 0.02), 0.34 (. sd. 0.02), 0.28 (. sd. 0.03) and 0.29 (. sd. 0.03), respectively. Conclusion. This method provides a simple, reproducible and reliable technique enabling accurate anatomical joint line restoration during revision total knee arthroplasty. Cite this article: B. Ozkurt, T. Sen, D. Cankaya, S. Kendir, K. Basarır, Y. Tabak. The medial and lateral epicondyle as a reliable landmark for
We aimed to obtain anthropometric data on Korean
knees and to compare these with data on commonly available total
knee arthroplasties (TKAs). The dimensions of the femora and tibiae
of 1168 knees were measured intra-operatively. The femoral components
were found to show a tendency toward mediolateral (ML) under-coverage
in small femurs and ML overhang in the large femurs. The ML under-coverage
was most prominent for the small prostheses. The ML/anteroposterior
(ML/AP) ratio of Korean tibiae was greater than that of tibial components. This study shows that, for different reasons, current TKAs do
not provide a reasonable fit for small or large Korean knees, and
that the ‘gender-specific’ and ‘stature-specific’ components help
for large Korean femurs but offer less satisfactory fits for small
femurs. Specific modifications of prostheses are needed for Asian
knees.
Abstract. Introduction. High posterior tibial slope (PTS) has been recognised as a risk factor for anterior cruciate ligament rupture and graft failure. This prospective randomised study looked at
Abstract. Introduction. There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty - The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using
Abstract. Introduction. Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. Methodology. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed. Results. Achondroplasia was the most common skeletal dysplasia (8), followed by Chondrodysplasia punctata (7) and Spondyloepiphyseal dysplasia (5). There were fourteen men and eight women with mean age of 51 years (28 to 73). The average height of patients was 1.4 metres (1.16–1.75) and the mean weight was 64.8 Kg (34.3–100). The mean follow up duration was 68.32 months (1–161). Three patients died during follow up. Custom implants were required in twelve patients (38.71%). Custom jigs were utilised in six patients and two patients underwent robotic assisted surgery. Hinged TKR was used in seventeen patients (54.84%), posterior stabilised TKR in nine patients (29.03%), and cruciate retaining TKR in five patients (16.13%). One patient underwent a patella resurfacing for persistent anterior knee pain and another had an
Abstract. Introduction. The prevalence of recurrent infection following two-stage exchange arthroplasty following failure of a total knee arthroplasty (TKA) has been reported to be 10% to 25%. There is limited literature available on repeat two stage revisions for TKA infection with only small cohorts and variable success rates. Methodology. A retrospective cohort study investigating the outcome of two stage revision arthroplasty for treatment of TKA infection was conducted with the aim of identifying factors linked to recurrence of infection. A consecutive cohort of all microbiology
Abstract. Introduction. Risk factors for osteoarthritis include raised BMI and female gender. Whether these two factors influenced synovial gene expression was investigated using a triangulation and modelling strategy which generated 12 datasets of gene expression in synovial tissue from three knee pathologies with matching BMI groups, obese and overweight, and gender distributions. Methodology.
Abstract. Introduction. Mako robotic assisted knee arthroplasty requires a planning CT scan within 8 weeks of surgery according to the supplier's protocol. This is often impractical, therefore we evaluated whether CT scans remain valid for an extended period. Methodology. Patients undergoing Mako partial (PKA) and total (TKA) knee arthroplasty were identified from our hospital database. The hospital PACS system was used to define the time interval between the initial planning CT scan and surgery, and whether further imaging was required prior to surgery. Results. 443 consecutive Mako cases (225 TKA and 218 PKA) were undertaken between November 2019 and December 2021 (33 cases to March 2020, and 410 cases from August 2020). CT scans were done within 8 weeks of surgery in 229 patients (51.7%); between 8 and 24 weeks in 148 patients (33.4%); between 24 and 48 weeks in 53 patients (12.0%); and more than 48 weeks in 13 patients (2.9%). Repeat pre-operative radiographs were done in the first 43 patients with a delay to surgery of more than 8 weeks following their CT scan. No gross anatomical changes were identified, and this practice was therefore discontinued. No patients required a repeat CT scan. There were no
Abstract. Introduction. Synovitis impacts osteoarthritis symptomatology and progression. The transcription factors controlling synovial gene expression have not been described. This study analyses gene expression in synovium samples from 16 patients with osteoarthritis with 9 undergoing arthroscopic and 8 knee trauma surgery for non-arthritic pathologies. Methodology.
Abstract. Introduction. Controversy exists regarding the optimal tibial coronal alignment in total knee arthroplasty. Many believe navigation or robotics are required to set kinematic alignments or to ensure they remain within ‘safe’ limits e.g. maximum 5° varus on the tibia. Given most navigation or robotic systems require the surgeon to identify the ankle malleoli, this study aimed to radiographically analyse standardly used
Introduction. The objective of this study is to assess the use of ultrasound (US) as a radiation free imaging modality to reconstruct three-dimensional knee anatomy. Methods. An OEM US system is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allowing for 3D tracking of probe and femur and tibia. The raw US RF signals are acquired and using real time signal processing, bone boundaries are extracted. Bone boundaries are then combined with the EM sensor information in a 3D point cloud for both femur and tibia. Using a statistical shape model, the patient specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was then conducted for 11 cadavers by comparing the 3D US models to those created using CT scans. Results. The results revealed the US bone models were accurate compared to the CT models (Mean RMS: femur: 1.03±0.15 mm, tibia:1.11± 0.13). Also, femoral landmarking proved to be accurate (transepicondylar axis: 1.07±0.65°, Posterior condylar axis: 0.73±0.41° Distal condylar axis: 1.12±0.89°, Medial AP: 1.39±1.18 mm, Lateral AP: 1.56±1.15 mm, TEA width: 1.2±0.87 mm). Tibial landmarking errors were slightly higher (Posterior slope axis: 2 ±1.19° and Tubercle axis: 1.8±1.37°). The models were then used to evaluate implant sizing as, 90% of the femurs and 60% of the tibias were sized correctly, while the others were off only one size. Discussion. The 3D US bone models were proven to be accurate compared to CT and can be used for preoperative planning. 3D ultrasound is radiation free and offers numerous clinical opportunities for bone creation in minutes during their office visit, surgeon-patient pre-operative planning, implant sizing and selection, 3D dynamic ligament balancing and
Introduction. Robot-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to quantify soft tissue laxity and adjust the plan prior to bone resection should reduce variability in polyethylene thickness. This study was performed to compare accuracy to plan for component positioning and polyethylene thickness in RA-TKA versus M-TKA. Methods. 199 consecutive primary TKAs (96 C-TKA and 103 RA-TKA) performed by a single surgeon were reviewed. Full-length standing and knee radiographs were obtained pre and post-operatively. For M-TKA, measured resection technique was used. Planned coronal plane femoral and tibial component alignment, and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9mm. For RA-TKA, individual component position was adjusted to assist balance the gaps but planned coronal plane alignment for the femoral and tibial components and overall limb alignment had to remain 0+/− 3°; planned tibial posterior slope was 1.5°. Planned values and polyethylene thickness for RA-TKA were obtained from the final
Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated the reliability of robotic assisted UKA over manual UKA in component placement and executing a soft-tissue tensioning plan. The purpose of this multicenter study was to determine the correlation between 3D component positioning and soft-tissue tensioning with short-term clinical results following robotic assisted medial UKA. Methods. Between 2013 and 2016, 349 patients (381 knees) underwent robotic assisted fixed bearing metal backed medial UKAs at two centres. Follow-up was performed at 12 months minimum. Pre- and post-operatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS), Forgotten Joint Score 12 (FJS), and Short-Form summary scale (SF-12) surveys. Clinical results for every score were stratified as ‘excellent’, ‘mild’ and ‘insufficient’. Post-operative complications were recorded. Failure mechanisms, reoperations and post-operative knee pain were also assessed.
Aims. The aims of this study were to determine the proportion of patients
with outlier varus or valgus alignment in kinematically aligned
total knee arthroplasty (TKA), whether those with outlier varus
or valgus alignment have higher forces in the medial or lateral
compartments of the knee than those with in-range alignment and
whether measurements of the alignment of the limb, knee and components
predict compartment forces. Patients and Methods. The
Objectives. The length of the tourniquet time during total knee arthroplasty (TKA) is related to the incidence of post-operative deep vein thrombosis (DVT). Our aim in this study was to investigate the effect of the early release of the tourniquet on the incidence of DVT in patients undergoing TKA. Methods. A total of 200 patients who underwent TKA between November 2015 and November 2016 were prospectively enrolled. The tourniquet was inflated before surgery and released immediately after the introduction of the components (early release group). This group was compared with a retrospective cohort of 200 primary TKAs, in which the tourniquet was released after the dressings had been applied (late release group). The presence of a DVT was detected using bilateral lower limb ultrasonography. Peri-operative clinical and follow-up data were collected for analysis. Results. The incidence of DVT in the early release group (9 of 196, 4.6%) was significantly lower compared with the late release group (24 of 200, 12%; odds ratio (OR) 0.35, 95% confidence interval (CI) 0.16 to 0.78, p = 0.008). The incidence of proximal DVT in the early release group (1 of 196 (0.5%)) was significantly lower than in the late release group (8 of 196, 4%; OR 0.12, 95% CI 0.02 to 0.99, p = 0.020). Although the mean
Introduction. t is accepted dogma in total knee arthroplasty (TKA) that resecting the posterior cruciate ligament (PCL) increases the flexion space by approximately 4mm, which significantly affects