Advertisement for orthosearch.org.uk
Results 1 - 20 of 23
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction. Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF. Objectives. To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA). Material and Methods. We performed a comparative retrospective study between two series of patients treated by fixed volar angle locking plate (40 patients) or volar buttress plate (36 patients). Distal radius fractures were classified by the AO/ASIF Müller classification after X-ray study in two views (Anteroposterios and lateral views), surgical treatment was indicated by the type of fracture (unstable fractures) and open fractures. Demographic information was gathered, injury mechanism and postoperatory complications. The minimal follow-up was 10 months. We performed clinical and radiographic evaluations before surgery, postoperatory, to 3 months and at the end of the follow-up (Palmar tilt, radial inclination, radial height and the radioulnar index were measured). Lidström's and Quick Dash scale, by means of telephonic survey, were used for the functional evaluation. Results. The time from fracture to surgery was on average 3.74 days in the group of DVR ® plates and 1.69 days for the group treated with T buttress plates. Henry's approach was realized in every case and the average time spent in surgery was 74 minutes for patients treated with T buttress plate and 80 minutes for patients treated with plate DVR®. In some cases K wires had to be used in 9 cases in the DVR® group and 7 in the other group. DVR® group obtained better results in radiological evaluation except in the radial inclination. In the Quick Dash scale, conducted a telephone survey, the average for the DVR® group was 26.40 (CI: 13.6 to 81.8) and 33.37 (CI: 10.2–90) for the group of T buttress plate (p=0.055). Conclusion. The potential advantages of ORIF in the distal radius fractures are low complication rate, stable subchondral fixation and early active movement of the wrist in the postoperative period. The disadvantages are a high cost, greater complexity and surgical exposure. Locking plates were designed to prevent postoperative collapse of the fracture also allows a better fix system in osteoporotic bone. Both types of plates obtained good results radiological and functional at the end of follow-up but we have obtained better results in the patients treated with locking plates


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 97 - 97
1 Sep 2012
Brorson S Frich LH Winther A Hrobjartsson A
Full Access

Introduction

There is considerable uncertainty about the optimal treatment of displaced four-part fractures of the proximal humerus. Within the last decade locking plate technology has been considered a breakthrough in the treatment of these complex injuries.

Methods

We systematically identified and reviewed clinical studies of the benefits and harms after osteosynthesis with locking plates in displaced four-part fractures.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims

To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial.

Methods

The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims

The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria.

Patients and Methods

Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives

The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator.

Materials and Methods

An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1544 - 1550
1 Nov 2013
Uchiyama S Itsubo T Nakamura K Fujinaga Y Sato N Imaeda T Kadoya M Kato H

This multicentre prospective clinical trial aimed to determine whether early administration of alendronate (ALN) delays fracture healing after surgical treatment of fractures of the distal radius. The study population comprised 80 patients (four men and 76 women) with a mean age of 70 years (52 to 86) with acute fragility fractures of the distal radius requiring open reduction and internal fixation with a volar locking plate and screws. Two groups of 40 patients each were randomly allocated either to receive once weekly oral ALN administration (35 mg) within a few days after surgery and continued for six months, or oral ALN administration delayed until four months after surgery. Postero-anterior and lateral radiographs of the affected wrist were taken monthly for six months after surgery. No differences between groups was observed with regard to gender (p = 1.0), age (p = 0.916), fracture classification (p = 0.274) or bone mineral density measured at the spine (p = 0.714). The radiographs were assessed by three independent assessors. There were no significant differences in the mean time to complete cortical bridging observed between the ALN group (3.5 months (se 0.16)) and the no-ALN group (3.1 months (se 0.15)) (p = 0.068). All the fractures healed in the both groups by the last follow-up. Improvement of the Quick-Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, grip strength, wrist range of movement, and tenderness over the fracture site did not differ between the groups over the six-month period. Based on our results, early administration of ALN after surgery for distal radius fracture did not appear to delay fracture healing times either radiologically or clinically.

Cite this article: Bone Joint J 2013;95-B:1544–50.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model.

A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads.

All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (sd 1500), 28 800 cycles (sd 6300), and 26 400 cycles (sd 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (sd 10 700), 36 000 cycles (sd 7200), and 36 600 cycles (sd 10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution.

In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives. We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone. Methods. Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading. Results. Locking plates in normal bone survived 10% fewer cycles to failure during cyclic axial loading, but there was no significant difference in maximum displacement or failure load. Locking plates in osteoporotic bone showed less displacement (p = 0.02), but no significant difference in number of cycles to failure or failure load during cyclic axial loading (p = 0.46 and p = 0.25, respectively). Locking plates in normal bone had lower stiffness and torque during torsion testing (both p = 0.03), but there was no significant difference in rotation (angular displacement) (p = 0.84). Locking plates in osteoporotic bone showed lower torque and rotation (p = 0.008), but there was no significant difference in stiffness during torsion testing (p = 0.69). Conclusions. The mechanical performance of locking plate constructs, using only two screws, is comparable to three non-locking screw constructs in osteoporotic bone. Normal bone loaded with either an axial or torsional moment showed slightly better performance with the non-locking construct


Bone & Joint Open
Vol. 3, Issue 12 | Pages 953 - 959
23 Dec 2022
Raval P See A Singh HP

Aims

Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK.

Methods

A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 258 - 258
1 Sep 2012
Garg B Kumar V Malhotra R Kotwal P Madan M
Full Access

Introduction. Locking plates have been especially useful in the treatment of osteoporotic fractures. This study aimed to investigate the role of locking plate in femoral fractures in patients with osteogenesis imperfecta. Material & Methods. 6 male patients with osteogenesis imperfecta were operated for femoral fractures using locking compression plate. Their age ranged between 4 and 14 years. They were kept non weight bearing till the fracture united. Results. 5 patients out of 6 patients had refracture, as soon as they started walking. All 5 patients were reoperated using intramedullary titanium elastic nails. All of them united later on and were walking full weight bearing at the end of one year. Conclusion. Our study indicates that locking plates should not be used in the treatment of fractures in patients with osteogenesis imperfecta


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 512 - 512
1 Sep 2012
Zlowodzki M Armitage B Wijdicks C Kregor P Bruce L Cole P
Full Access

Introduction. The most common treatment options for fixation of osteoporotic distal femur fractures are retrograde nails and locking plates. There are proponents of more elastic titanium plates as well as more rigid steel plates; No clear superiority of one over the other has been established. We aimed to evaluate the mechanical differences between stainless steel and titanium locking plates in the fixation of distal femur fractures in osteoporotic bone. We hypothesized that due to its higher elasticity titanium locking plates can absorb more energy and are therefore less likely to “cut” into the bone compared to stainless steel locking plates resulting in improved metaphyseal osteoporotic fracture fixation. Methods. We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Within each pair we randomized one femur to be fitted with a Less Invasive Stabilization System (LISS-Titanium locking plate) and one with a Distal Locking Condylar Plate (DLCP-Stainless steel locking plate). A fracture model simulating an AO 33-A3 fracture was created (extraarticular comminuted fracture) and specimens were subsequently subjected to step-wise cyclic axial loading to failure. We used an advanced three dimensional tracking system (Polhemus Fastrak) to monitor the movement of the distal fragment relative to the real time distal plate position allowing us to evaluate distal implant cut-out. Results. During cyclic testing, seven of the eight pairs of matched femurs, the DLCP failed before the LISS plate (p=0.03). All constructs were able to withstand cyclical loading up to 800N. The overall plastic deformation as measured by the displacement of the Instron crosshead experienced by the titanium plate constructs was significantly lower compared to the stainless steel plate construct: The plastic deformation of the LISS plates was 39% lower compared to the Locking Condylar plates after cycle testing at 400 Newtons and 70% lower at 800N. Furthermore during the 800N cycle testing the LISS plating system showed a significantly lower rate of plastic deformation not only for the entire bone-implant construct, but also between the plate and the distal fragment than the locking condylar plate (=less distal implant cut-out). Conclusions. The use of a more advanced three dimensional tracking system, fresh-frozen osteoporotic matched human specimen and the ability to test all constructs to failure allowed us a more thorough comparison of titanium versus stainless steel implants compared to previous studies. The titanium locking plates provided an overall superior fixation of osteoporotic distal femur fractures with less distal implant cut-out, a better elastic recoil, and a slower rate of residual plastic deformation


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims

The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years.

Methods

From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 6 - 6
1 Sep 2012
Upadhyay P Beazley J Dunbar M Costa M
Full Access

Introduction. Locking compression plate (LCP) fixation is an established method of treatment of distal third tibial fractures. No biomechanical data exists in the literature regarding their use. Additionally no data exists on the biomechanical advantage of locking screw fixation over non-locking screw fixation for these fractures. In this study the axial and torsional stiffness, axial load to failure and fatigue performance of a 3.5 mm LCP medial distal tibia Synthes plate was evaluated for the stabilisation of distal third tibial fractures. Additionally the performance of the plate in uni and bicortical locked mode as well as non-locked mode was evaluated. Methods. A standardized oblique fracture pattern was created in the tibial metaphysis of 3rd generation composite tibias, 40 mm from the distal end of the tibia (AO 43-A2.3). A 10mm fracture gap was used to model a comminuted metaphyseal fracture. A 3.5 mm medial distal tibia LCP was applied with bi or unicortical locking or bicortical non-locking screws to 5 tibias respectively. All the bio-mechanical tests were performed on a Bose 3510 Electroforce material testing machine. A ramp to load, loading profile was used to determine the static axial and torsional performance of the construct. Fatigue testing simulated a 6 week gradual weight bearing régime with the load increasing every two weeks by 400N until either 250,000 cycles were completed or the construct failed. Results. The non-locked plate demonstrated a significantly higher load to failure than both the bicortical and unicortical locked plates, 683N vs. 575N vs. 483N respectively(p<0.01). The non locked plate also demonstrated significantly higher mean axial stiffness than the bicortical locked plate and unicortical locked plate 632±13 N/mm, 337±12N/mm and 266±6 N/mm respectively (p <0.01). The non locked plate demonstrated the highest torsional stiffness followed by the bi and unicortical locking plates 1.16 ±.08 Nmm vs. 0.79 ± .06 Nmm vs.0.40 ± 0.02 Nmm respectively (p < 0.01). The non locked plate demonstrated higher endurance than the bi and unicortical locking plates over a 6 week simulated fatigue cycle with 1.75mm, 2.10mm and 2.3mm residual displacement at 1600N respectively (p < 0.01). Discussion. This is the first study that has examined the biomechanical properties of the LCP when used for distal third tibial fractures. A review of the literature suggests LCPs outperform dynamic compression plates in osteoporotic bone but demonstrates no clear biomechanical advantage in using a locking construct in non-osteoporotic bone. In our study the non locked construct outperformed the locked constructs in all parameters assessed. We conclude there is no advantage in using a locking construct for distal third tibial fractures in good quality bone


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 624 - 633
1 May 2018
Maredza M Petrou S Dritsaki M Achten J Griffin J Lamb SE Parsons NR Costa ML

Aim

The aim of this study was to compare the cost-effectiveness of intramedullary nail fixation and ‘locking’ plate fixation in the treatment of extra-articular fractures of the distal tibia.

Patients and Methods

An economic evaluation was conducted from the perspective of the United Kingdom National Health Service (NHS) and personal social services (PSS), based on evidence from the Fixation of Distal Tibia Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients were available for analysis. Costs were collected prospectively over the 12-month follow-up period using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality adjusted life year (QALY) gained, and net monetary benefit. Sensitivity analyses were conducted to test the robustness of cost-effectiveness estimates.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims

Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees.

Methods

A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.