Metaphyseal bone loss is common with revision
total knee replacement (RTKR). Using the Anderson Orthopaedic Research
Institute (AORI) classification, type 2-B and type 3 defects usually
require large metal blocks, bulk structural allograft or highly
porous metal cones. Tibial and femoral trabecular metal metaphyseal
cones are a unique solution for large bone defects. These cones
substitute for bone loss, improve
Aim. One of the most challenging problems in total knee arthroplasty (TKA) is periprosthetic infection. A major problem that arises in septic revision TKA (RTKA) are extended bone defects. In case of extended bone defects revision prostheses with metaphyseal sleeves are used. Only a few studies have been published on the use of metaphyseal sleeves in RTKA - none were septic exclusive. The aim of our study was to determine the implant survival, achieved osseointegration as well as the radiological mid-term outcomes of
Aims. Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This
Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term implant survivorship, risk factors, complications, and clinical outcomes of contemporary primary THAs in this difficult cohort. Our institutional total joint registry was used to identify 119 primary THAs performed in 109 patients with an angular proximal femoral deformity between 1997 and 2017. The deformity was related to previous femoral osteotomy in 85%, and developmental or metabolic disorders in 15%. 53% had a predominantly varus angular deformity. The mean age was 44 years, mean BMI was 29 kg/m. 2. , and 59% were female. An uncemented
Shoulder arthroplasty is effective at restoring function and relieving pain in patients suffering from glenohumeral arthritis; however, cortex thinning has been significantly associated with larger press-fit stems (fill ratio = 0.57 vs 0.48; P = 0.013)1. Additionally, excessively stiff implant-bone constructs are considered undesirable, as high initial stiffness of rigid fracture fixation implants has been related to premature loosening and an ultimate failure of the implant-bone interface2. Consequently, one objective which has driven the evolution of humeral stem design has been the reduction of stress-shielding induced bone resorption; this in-part has led to the introduction of short stems, which rely on
Aims.
This was a randomised controlled trial studying
the safety of a new short
Aims. Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded. Results. The patient demographics were statistically similar in the two cohorts. The median follow-up was 3.5 years (interquartile range (IQR) 1 to 12.5). Supplementary femoral
Introduction. Modularity in femoral stem designs allow surgeons to independently control leg length, offset, and femoral version in revision or complex primary THA cases. Initial enthusiasm in these modular stems has been tempered by recognition of modular junction failures. This study evaluates mean 5-year clinical results and survival rates of a 3-part titanium alloy modular femoral implant with unique taper geometries and a metaphyseal plasma spray surface. The current results are presented after pre-market independent fatigue testing performed by Orthopaedic Laboratory (Greenwald) and previously published early clinical results in 2006. Low plasticity burnishing (LPB) was added in 2005 to further strengthen the neck metaphyseal modular junction. The modular stem component is a polished cylindrical splined clothespin design. Our hypothesis is that these unique modular junctions succeed in offering the advantages of modularity without failure at this midterm follow-up period. Methods. Between May 2010 and July 2016, 32 total hip arthroplasties were performed using a 3-part femoral stem with neck-metaphyseal-stem modular junctions. Surgeries were either the final stage of a two-stage revision for infection, revision THR for loosening, or a revision of a previous non-prosthetic replacement procedure. Patients were entered into an IRB-approved registry and followed with x-rays, HHS, Oxford scores, and patient satisfaction scores. Patients who failed to return for routine follow-up were contacted by phone or email. Two patients had died with their implants intact. Six patients could not be reached for an updated follow-up. One stem was revised for loosening at 33 months due to failed osseointegration in a patient with chronic renal failure. This removed stem was submitted for taper exam and sectioning. Results. There were 23 patients for evaluation at a mean 61 months (range 21–98). Mean patient age at implantation was 56 (range 25–88), BMI was 27 (range 20–40). There were no modular junction failures. Modular junctions examined in the retrieved implant did not demonstrate any abnormalities other than normal wear properties. HHS and OHS scores both improved between pre-op and final follow-up, 23 to 85 and 17 to 43, respectively. Average patient satisfaction score at final follow-up was 9.8 out of 10 (min 8, max 10). Radiographic examination showed stem subsidence > 2mm and radiolucencies around the metaphyseal cone in 1 patient, the same patient who required implant removal. Radiolucencies were seen along the polished stem tip in 43% of cases, spot welding at the distal metaphyseal cone in 67% of cases, and mild proximal-medial stress shielding in 33% of cases. Conclusion. This unique 3-part modular stem with
Aims. There is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome. Patients and Methods. We retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m. 2. (20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had
Introduction. The optimal management of severe tibial and/or femoral bone loss in a revision total knee arthroplasty (TKA) has not been established. Reconstructive methods include structural or bulk allografts, impaction bone-grafting with or without mesh augmentation, custum prosthetic components, modular metal augmentations of prosthesis and tumor prosthesis. Recently
The treatment of bone loss in revision total
knee arthroplasty has evolved over the past decade. While the management
of small to moderate sized defects has demonstrated good results
with a variety of traditional techniques (cement and screws, small
metal augments, impaction bone grafting or modular stems), the treatment of
severe defects continues to be problematic. The use of a structural
allograft has declined in recent years due to an increased failure
rate with long-term follow-up and with the introduction of highly
porous metal augments that emphasise biological
Aim: The purpose of this study was to evaluate the results of transphyseal ACL reconstruction technique in skeletally immature patients. Material &
Methods: Between 2002 and 2008, twenty knees in twenty skeletally immature patients with a mean chronological age of 13.2 years (range, 7 to 16.2 years) underwent transphyseal reconstruction of the anterior cruciate ligament with use of an autogenous quadrupled hamstrings-tendon graft with
The February 2014 Hip &
Pelvis Roundup. 360 . looks at: length of stay; cementless
Introduction.
Introduction. Tibial component loosening is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include isolated tibial component revision or full component revision. A full component revision is frequently selected by surgeons who are unfamiliar with the existing implant or have a “let's just start over attitude.” This option adds morbidity versus isolated tibial exchange. While isolated tibial exchange has lower morbidity, it is technically more challenging with regard to exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients revised for isolated aseptic tibial loosening were identified from 2012–2017. Patients with revision implants, or those revised for infection, instability, osteolysis, or femoral component loosening were excluded. 161 patients met these criteria, 85 patients had an isolated tibial revision and 76 had revision of both components despite having only a loose tibial component. Patient demographics as well as clinical and radiographic outcomes were recorded for each cohort. Results. Patient demographical information, including age, gender, and BMI were statistically similar between the two cohorts. Median follow-up was 3.5 years. Supplemental
Introduction. Periprosthetic joint infection (PJI) remains the main cause of failure in primary and revision total knee arthroplasties (TKAs). Local delivery of antibiotics, mainly antibiotic-loaded bone cement (ALBC), is commonly employed to prevent PJI. Over the past decade, tantalum and porous titanium have been successfully utilized as
Bone loss creates a challenge to achieving fixation in revision TKR. Failure to achieve
Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.Aims
Methods
We describe three cases of fracture of the titanium JRI-Furlong hydroxyapatite-ceramic (HAC)-coated femoral component. We have examined previous case reports of failure of this stem and conclude that fracture may occur in two places, namely at the neck-shoulder junction and at the conical-distal cylindrical junction. These breakages are the result of fatigue in a metallurgically-proven normal femoral component. All the cases of failure of the femoral component have occurred in patients with a body mass index of more than 25 in whom a small component, either size 9 or 10, had been used. In patients with a body mass index above normal size 9 components should be avoided and the femoral canal should be reamed sufficiently to accept a large femoral component to ensure that there is adequate