Stable fractures of the ankle can be successfully treated non-operatively by a below-knee
Introduction. To investigate if the gap index measured in the follow-up X-rays predicts the reduction of swelling in the
We have had experience of an 18-month-old boy with a cardiomyopathy who died a few minutes after removal of his cast with a saw, apparently from a malignant cardiac arrhythmia triggered by anxiety. We therefore examined the anxiety reaction to this method of removal of a
Introduction and objectives: The most commonly used treatment for extraarticular fractures of distal radius is closed reduction and maintenance of reduction in a cast. Two types of casts are used: plaster splint for 7–10 days and later exchanged to a circular cast and the use of circular cast immediately. The objective of this work is to compare both types of treatment in terms of ability to achieve reduction and to maintain it during healing. Methods: A prospective, randomized and blinded study was designed. To date, 21 patients enrolled the study. Informed consent was given. The inclusion criteria were: older than 35 years, extraarticular distal radius fracture sustained less than 24 hours before and not previously treated. Exclusion criteria included previous injury in the same wrist, open fracture, and not compliance with the protocol. After intrafocal anesthesia with mepivacaine 1%, fracture was reduced under traction and immobilized in a dorsal short plaster splint (splint group) or a circular short
Aim: A prospective randomised clinical trial was performed to evaluate two forms of immobilisation in the treatment of colles fractures not requiring manipulation. Methods: Patients were randomised to either
Most of current literatures advise on thromboprophylaxis with injectable LMWH for trauma patients. Injectable anticoagulants have got inherent problems of pain, bruising and difficulty in administering the drug, which leads to low compliance. Clexane is derived from a pig's intestinal mucosa, hence could be objectionable to certain proportion of patients because of their religious beliefs. Oral anticoagulants have been used as thromboprophylactic agents in hip and knee arthroplasty. However there is not enough literature supporting their use as thromboprophylactic agent in ambulatory trauma patients with ankle fracture being managed non-operatively as out-patient. This study looks into the efficacy of oral anticoagulant in preventing VTE in ambulatory trauma patients requiring temporary lower limb immobilisation for management of ankle fracture. The end point of this study was symptomatic deep vein thrombosis (either proximal or distal) and pulmonary embolism. Routine assessment with a VTE assessment risk proforma for all patients with temporary lower limb immobilisation following lower limb injury requiring
The use of Orthoplast cast-bracing to allow early hand function in the treatment of displaced Colles' fractures was investigated in 243 patients. They were randomly allocated into three groups: in the first a conventional Colles' type plaster was used; in the second an above-elbow cast-brace with the forearm in supination; and in the third a below-elbow cast-brace. Radiographic measurements were made at each stage of treatment, and the final anatomical result was scored using Sarmiento's (1975) criteria. Function was assessed at three months and at six months. The anatomical result was not influenced by the method of immobilisation but was related to the efficacy of reduction. Loss of position in the braces was no greater than in plaster. The functional result at three months also was uninfluenced by the method of immobilisation; it was, however, related to the severity of the initial displacement, and (to a lesser degree) to the anatomical result, an effect which was lost at six months. Early hand function and the supinated position advocated by Sarmiento were found to confer no anatomical or functional advantage; we could see no reason to change from the use of conventional
Introduction. Venous thromboembolism (VTE) is a significant cause of patient morbidity and mortality, the risk of which increases in orthopaedic patients with lower limb immobilisation. This incidence should in theory reduce if the patients are ambulatory early in the treatment phase. The aim of this study was, therefore, to identify a difference in the incidence of symptomatic VTE by treating acute Achilles tendon rupture patients with conventional non-weight bearing plaster versus functional weight bearing mobilisation. Methodology. The notes of 91 consecutive patients with acute Achilles tendon rupture were retrospectively reviewed and prospectively followed. The patients' demographics, treatment modality (non-weight bearing plaster versus weight bearing boot), and the type of plaster immobilisation was compared to assess whether they affect the incidence of clinical VTE. The predisposing risk factors were also analysed between the treatment groups. Out of 91 patients, 50 patients with acute Achilles tendon rupture were treated conservatively in a conventional non-weight bearing immobilisation cast. From these 50 patients, 3 then underwent surgery and were therefore excluded from the results. On the other hand, 41 patients were treated with functional weight bearing mobilisation (Vacupad). Patients who did have a symptomatic thromboembolic event also had an ultrasound scan to confirm a deep vein thrombosis of the lower limb or a CT-scan to confirm pulmonary embolism. Results. Out of the 47 patients who were treated conservatively in a non-weight bearing
Introduction. Peri prosthetic fracture is a recognised complication following Total ankle arthroplasty (TAA). There is limited literature on post operative management following TAA and controversies exist based on surgeon preferences. This project reports the incidence of peri- prosthetic fractures in patients managed with 2 different post-operative protocols. Materials and Methods. Patients undergoing primary TAA with a diagnosis of Osteoarthritis (OA) or Post-traumatic Osteoarthritis (PTOA) were recruited into a randomized controlled trial. These patients did not require any additional procedures. Patients were consented for the trial and randomized to one of two treatment groups (Early mobilisation after surgery vs. immobilisation in a
Introduction/Aim. Thromboembolism is a significant cause of patient morbidity and mortality, the risk of which increases in orthopaedic patients with lower limb immobilisation. It was therefore, our aim to identify a difference in symptomatic thromboembolism by treating acute Achilles tendon rupture patients with conventional non-weight bearing plaster versus functional weight bearing mobilisation. Methodology. The notes of 91 consecutive patients with acute Achilles tendon rupture were reviewed. The patients demographics, treatment modality (non-weight bearing plaster versus weight bearing boot), and predisposing risk factors were analysed. From the 91 patients, 50 patients with acute Achilles tendon rupture were treated conservatively in a non-weight bearing immobilisation cast. From these 50 patients, 3 then underwent surgery and were therefore excluded from the results. 41 patients were treated with functional weight bearing mobilisation. Patients who did have a symptomatic thromboembolic event had an ultrasound scan to confirm a deep vein thrombosis of the lower limb, or a CT-scan to confirm pulmonary embolism. Results. Out of the 47 patients who were treated conservatively in a non-weight bearing
Rockers are applied to lower limb casts to assist walking but there is little information on their biomechanical effects. The performances of 10 commercially available rockers were compared. They were applied to a below-knee cast worn by a normal subject who was also tested walking in the cast alone. Gait analysis was used to evaluate kinematic and kinetic data. The design of rocker had no effect upon the kinematics of walking. However, using new criteria for kinetic assessment of rocker function (tibial floor angular velocity and centre of pressure progression), most designs had a deleterious effect on the biomechanics of gait. Only two rockers approached the ideal kinetic criteria.
To demonstrate the effect of location of the split of the plaster on the raised intercompartmental pressure in the volar and dorsal compartments. Artificial forearm skeleton was used along with two half litre saline bags on ether side representing volar and dorsal forearm compartment. A single layer of cotton wool with half width overlap was applied followed by three rolls of 10cm x 2.5 m plaster of paris. This was then left to dry for four hours. Both the saline bags had an eighteen gauge catheter inserted that was connected to the central venous pressure monitoring line on the anaesthetic machine. Baseline pressure in mmHg was recorded. Normal saline was then injected in both the bags so as to raise the pressure to 50 mmHg in each compartment. POP cast was then split, spread and then the wool was cut down to the saline bags while continually monitoring the pressures. The respective change in the pressure at the end of each step was recorded. Six simulated forearm models had dorsal splits and an equal number had volar splits. The effect of the site and various steps of splitting on the drop in respective compartment pressures was compared.Aim
Methods
We hypothesised that adjuvant intermittent pneumatic
compression (IPC) beneath a
The aim of this study was to assess the usefulness of Cast index and an indigenously developed Gap index as measures of poor moulding of plaster. 20 cases of re-manipulation of distal third forearm fractures excluding growth plate injuries were compared with a control of 80 patients. 5 patients in the control group had an axial deviation of more than 10 degrees but were not remanipulated and therefore were included in the failure group. The gap index and the cast index of the two groups was compared as predictors of failure of conservative treatment. The groups were similar in terms of demography and post reduction alignment. There was a significant difference (<
0.001) in the Cast index and the Gap index of both the groups. The sensitivity of the Cast index (>
0.8) in predicting failure of plaster was 48% while that of the sum of Gap index (>
0.15) in AP &
Lat view was 88%. Gap index was found to be more accurate (84%) than Cast index (78%) in predicting failure. The gap index is a better predictor of failure than the cast index. A quick assessment of these indices, especially by the less experienced surgeons, is a good practice before accepting any plaster following a manipulation of distal radial fractures. It would not only save the patient a second anaesthesia but also complications of a more extensive second procedure and of course hospital resources.
We aimed to assess a simple radiological method of predicting redisplacement of paediatric forearm fractures. The Cast Index (CI) is the ratio of sagittal to coronal width from the inside edges of the cast at the fracture site. CI of 0.7 was used as the benchmark in predicting fracture redisplacement. Case records and radiographs of 1001 children who underwent a manipulation under general anaesthesia for a displaced fracture of the distal forearm were studied. Redisplacement was defined as more than 15 degrees of angulation and/or more than 80 percent of translational displacement on check radiographs at 2 weeks. Angulation (in degrees) and translation displacement (in percentage) were measured on the initial and check radiographs. The Cast index was measured on the check radiographs. Good intra and inter observer reproducibility was observed for both these measurements. The cast index has been previously validated in an experimental study. The adequacy of reduction after manipulation was estimated by the postreduction translation and angulation of the radius and ulna in anteroposterior and lateral plain film radiographs. The 1001 patients who qualified for the study, fracture redisplacement was seen in 107 cases at the all important two week follow up. Seven hundred and fifty-two patients had cast indices of 0.8 or less whilst 249 had casting indices of 0.81 or more. In patients with cast indices of 0.8 or less, the displacement rate was only 5.58%. However, in patients with cast indices of 0.81 or more, the displacement rate was 26%. Initial displacement, angulation and the post manipulation cast index were the three factors which were significantly higher in the redisplacement group. No statistically significant difference was seen for age, sex or ethnicity. Nor were statistical differences noted in initial angular deformity, initial displacement and seniority of the surgeon. There was no statistical difference in patients with cast indices between 0.7 and 0.8. Cast index is a simple reliable radiographic measurement to predict the redisplacement of forearm fractures in children. A plaster with a CI of >
0.81 is prone to redisplacement. A high cast index is associated with redisplacement of fractures and should therefore be considered when moulding casts is distal forearm fractures.
Only 10–15% of those thought clinically to have a fractured scaphoid are confirmed as having fractures on initial radiographs. A further 1–20% of those who had initially negative radiographs go on to have fractures confirmed on subsequent radiographs taken 10–14 days later. Fifty patients initially considered clinically to have scaphoid fractures were identified: 32 females and 18 males, with a mean age of 32 years, range 10–88 years, 68% were noted to have injured their dominant hand. Four patients, (8%), had scaphoid fractures identified on initial radiographs and only 1 patient, (2%), was found to have an occult scaphoid later. Three patients were found to have other bony injuries leaving 42 patients, (84%), having no fracture identified. Thirty-eight of this final group could be contacted and completed telephone questionnaires. The remaining 4 were lost to follow up. Patients were asked questions about employment, time off work, interference with other activities and general satisfaction with treatment. The mean time in plaster was 16 days, range 9–42 days. Eighteen of those in work, (47% of the total, 66.7% of the workers), had time off work. The mean length of time off work was 18.4 days, range 14–42 days. Sixteen of these received full “sick pay” for their time off. Personal hygiene was affected in 84%, housework in 37.5%, sports/hobbies for 55%, driving in 76% and social activities in 11.8%. Only 2 patients overall, suffered personal financial loss which amounted to less than one hundred pounds each. Only 3 people, (8%), expressed dissatisfaction with their management when directly questioned. All patients would have preferred an immediate diagnosis had this been possible. Alternative to this treatment including bone scanning and MRI are discussed.
Objectives. We aimed to examine the characteristics of deep venous flow in
the leg in a cast and the effects of a wearable neuromuscular stimulator
(geko; FirstKind Ltd) and also to explore the participants’ tolerance
of the stimulator. Methods. This is an open-label physiological study on ten healthy volunteers.
Duplex ultrasonography of the superficial femoral vein measured
normal flow and cross-sectional area in the standing and supine
positions (with the lower limb initially horizontal and then elevated).
Flow measurements were repeated during activation of the geko stimulator
placed over the peroneal nerve. The process was repeated after the
application of a below-knee cast. Participants evaluated discomfort
using a questionnaire (verbal rating score) and a scoring index
(visual analogue scale). Results. The geko device was effective in significantly increasing venous
blood flow in the lower limb both with a
Aims. The aim of this study was to compare the longer-term outcomes of operatively and nonoperatively managed patients treated with a removable brace (fixed-angle removable orthosis) or a