Advertisement for orthosearch.org.uk
Results 1 - 20 of 181
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 507 - 514
1 Mar 2021
Chang JS Kayani B Wallace C Haddad FS

Aims. Total knee arthroplasty (TKA) using functional alignment aims to implant the components with minimal compromise of the soft-tissue envelope by restoring the plane and obliquity of the non-arthritic joint. The objective of this study was to determine the effect of TKA with functional alignment on mediolateral soft-tissue balance as assessed using intraoperative sensor-guided technology. Methods. This prospective study included 30 consecutive patients undergoing robotic-assisted TKA using the Stryker PS Triathlon implant with functional alignment. Intraoperative soft-tissue balance was assessed using sensor-guided technology after definitive component implantation; soft-tissue balance was defined as intercompartmental pressure difference (ICPD) of < 15 psi. Medial and lateral compartment pressures were recorded at 10°, 45°, and 90° of knee flexion. This study included 18 females (60%) and 12 males (40%) with a mean age of 65.2 years (SD 9.3). Mean preoperative hip-knee-ankle deformity was 6.3° varus (SD 2.7°). Results. TKA with functional alignment achieved balanced medial and lateral compartment pressures at 10° (25.0 psi (SD 6.1) vs 23.1 psi (SD 6.7), respectively; p = 0.140), 45° (21.4 psi (SD 5.9) vs 20.6 psi (SD 5.9), respectively; p = 0.510), and 90° (21.2 psi (SD 7.1) vs 21.6 psi (SD 9.0), respectively; p = 0.800) of knee flexion. Mean ICPD was 6.1 psi (SD 4.5; 0 to 14) at 10°, 5.4 psi (SD 3.9; 0 to 12) at 45°, and 4.9 psi (SD 4.45; 0 to 15) at 90° of knee flexion. Mean postoperative limb alignment was 2.2° varus (SD 1.0°). Conclusion. TKA using the functional alignment achieves balanced mediolateral soft-tissue tension through the arc of knee flexion as assessed using intraoperative pressure-sensor technology. Further clinical trials are required to determine if TKA with functional alignment translates to improvements in patient satisfaction and outcomes compared to conventional alignment techniques. Cite this article: Bone Joint J 2021;103-B(3):507–514


Bone & Joint Open
Vol. 5, Issue 9 | Pages 758 - 765
12 Sep 2024
Gardner J Roman ER Bhimani R Mashni SJ Whitaker JE Smith LS Swiergosz A Malkani AL

Aims

Patient dissatisfaction following primary total knee arthroplasty (TKA) with manual jig-based instruments has been reported to be as high as 30%. Robotic-assisted total knee arthroplasty (RA-TKA) has been increasingly used in an effort to improve patient outcomes, however there is a paucity of literature examining patient satisfaction after RA-TKA. This study aims to identify the incidence of patients who were not satisfied following RA-TKA and to determine factors associated with higher levels of dissatisfaction.

Methods

This was a retrospective review of 674 patients who underwent primary TKA between October 2016 and September 2020 with a minimum two-year follow-up. A five-point Likert satisfaction score was used to place patients into two groups: Group A were those who were very dissatisfied, dissatisfied, or neutral (Likert score 1 to 3) and Group B were those who were satisfied or very satisfied (Likert score 4 to 5). Patient demographic data, as well as preoperative and postoperative patient-reported outcome measures, were compared between groups.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 80 - 80
7 Aug 2023
Liu A Qian K Dorzi R Alabdullah M Anand S Maher N Kingsbury S Conaghan P Xie S
Full Access

Abstract

Introduction

Knee braces are limited to providing passive support. There is currently no brace available providing both continuous monitoring and active robot-assisted movements of the knee joint. This project aimed to develop a wearable intelligent motorised robotic knee brace to support and monitor rehabilitation for a range of knee conditions including post-surgical rehabilitation. This brace can be used at home providing ambulatory continuous passive movement obviating the need for hospital admissions.

Methodology

A wearable sensing system monitoring knee range of motion was developed to provide remote feedback to clinicians and real-time guidance for patients. A prototype of an exoskeleton providing dynamic motion assistance was developed to help patients complete their exercise goals and strengthen their muscles. The accuracy and reliability of those functions were validated in human participants during exercises including knee flexion/extension (FE) in bed and in chair, sit-to-stand and stand-to-sit.


Introduction. The purpose of this study was to use patient generated digital surveillance PROM's to track outcomes of TKA, Medial PKA, Lateral PKA. Methods. From Aug 2018 until June 2019 we performed 873 knee arthroplasties. Of these, 41 were fixed bearing lateral partial knee replacements (5%), 309 medial partial knee replacements (35%), and 523 total knee replacements (60%). The average age was 65 years old and 59% were female. KOOS-Jr scores were recorded preoperatively, and 6, 12 months postoperatively using digital surveillance technology with a greater than 90% response rate. Results. Baseline, 6 month, and 12 month KOOS-JR scores for TKR (54, 76, 79) were not different than baseline, 6 month, and 12 month KOOS-JR scores for medial PKA (56, 78, 82) [p values of 0.23, 0.32, 0.20 respectively]. Baseline and 6 month KOOS-JR scores for TKR were not different than baseline and 6 month KOOS-JR scores for lateral PKA (55, 77) [p values of 0.35 and 0.50 respectively). Where as, the 12 month KOOS-JR scores for TKR (79) were significantly less than 12 month KOOS-JR scores for lateral PKA (84)[p value of 0.04]. Baseline, 6 month, and 12 month KOOS-JR scores for medial PKR were not different than lateral PKR (55, 77, 84) [p values of 0.49, 0.39, 0.20]. Conclusions. Prospective digital surveillance of PROM following knee arthroplasty has proven to be a cost-effective strategy. Short term improvements in PROM's following TKA and medial PKA were not different. Lateral PKA demonstrated statistically significant higher 1 year PROM but unlikely clinically significant. Longer-term follow-up is needed for determination of implant and unreplaced compartment survivorship. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1333 - 1338
1 Oct 2014
Gustke KA Golladay GJ Roche MW Jerry GJ Elson LC Anderson CR

The aim of this prospective multicentre study was to report the patient satisfaction after total knee replacement (TKR), undertaken with the aid of intra-operative sensors, and to compare these results with previous studies. A total of 135 patients undergoing TKR were included in the study. The soft-tissue balance of each TKR was quantified intra-operatively by the sensor, and 18 (13%) were found to be unbalanced. A total of 113 patients (96.7%) in the balanced group and 15 (82.1%) in the unbalanced group were satisfied or very satisfied one year post-operatively (p = 0.043).

A review of the literature identified no previous study with a mean level of satisfaction that was greater than the reported level of satisfaction of the balanced TKR group in this study. Ensuring soft-tissue balance by using intra-operative sensors during TKR may improve satisfaction.

Cite this article: Bone Joint J 2014;96-B:1333–8


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results. There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion. Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA. Cite this article: Bone Joint J 2024;106-B(7):680–687


Bone & Joint Open
Vol. 5, Issue 11 | Pages 992 - 998
6 Nov 2024
Wignadasan W Magan A Kayani B Fontalis A Chambers A Rajput V Haddad FS

Aims. While residual fixed flexion deformity (FFD) in unicompartmental knee arthroplasty (UKA) has been associated with worse functional outcomes, limited evidence exists regarding FFD changes. The objective of this study was to quantify FFD changes in patients with medial unicompartmental knee arthritis undergoing UKA, and investigate any correlation with clinical outcomes. Methods. This study included 136 patients undergoing robotic arm-assisted medial UKA between January 2018 and December 2022. The study included 75 males (55.1%) and 61 (44.9%) females, with a mean age of 67.1 years (45 to 90). Patients were divided into three study groups based on the degree of preoperative FFD: ≤ 5°, 5° to ≤ 10°, and > 10°. Intraoperative optical motion capture technology was used to assess pre- and postoperative FFD. Clinical FFD was measured pre- and postoperatively at six weeks and one year following surgery. Preoperative and one-year postoperative Oxford Knee Scores (OKS) were collected. Results. Overall, the median preoperative navigated (NAV) FFD measured 6.0° (IQR 3.1 to 8), while the median postoperative NAV FFD was 3.0° (IQR 1° to 4.4°), representing a mean correction of 49.2%. The median preoperative clinical FFD was 5° (IQR 0° to 9.75°) for the entire cohort, which decreased to 3.0° (IQR 0° to 5°) and 2° (IQR 0° to 3°) at six weeks and one year postoperatively, respectively. A statistically significant improvement in PROMs compared with baseline was evident in all groups (p < 0.001). Regression analyses showed that participants who experienced a larger FFD correction, showed greater improvement in PROMs (β = 0.609, p = 0.049; 95% CI 0.002 to 1.216). Conclusion. This study found that UKA was associated with an approximately 50% improvement in preoperative FFD across all three examined groups. Participants with greater correction of FFD also demonstrated larger OKS gains. These findings could prove a useful augment to clinical decision-making regarding candidacy for UKA and anticipated improvements in FFD


Bone & Joint Open
Vol. 4, Issue 10 | Pages 791 - 800
19 Oct 2023
Fontalis A Raj RD Haddad IC Donovan C Plastow R Oussedik S Gabr A Haddad FS

Aims. In-hospital length of stay (LOS) and discharge dispositions following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, it is imperative to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge dispositions following robotic arm-assisted total knee arthroplasty (RO TKA) and unicompartmental arthroplasty (RO UKA) versus conventional technique (CO TKA and UKA). Methods. This large-scale, single-institution study included patients of any age undergoing primary TKA (n = 1,375) or UKA (n = 337) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for post anaesthesia care unit (PACU) admission, anaesthesia type, readmission within 30 days, and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge. Results. The median LOS in the RO TKA group was 76 hours (interquartile range (IQR) 54 to 104) versus 82.5 (IQR 58 to 127) in the CO TKA group (p < 0.001) and 54 hours (IQR 34 to 77) in the RO UKA versus 58 (IQR 35 to 81) in the CO UKA (p = 0.031). Discharge dispositions were comparable between the two groups. A higher percentage of patients undergoing CO TKA required PACU admission (8% vs 5.2%; p = 0.040). Conclusion. Our study showed that robotic arm assistance was associated with a shorter LOS in patients undergoing primary UKA and TKA, and no difference in the discharge destinations. Our results suggest that robotic arm assistance could be advantageous in partly addressing the upsurge of knee arthroplasty procedures and the concomitant healthcare burden; however, this needs to be corroborated by long-term cost-effectiveness analyses and data from randomized controlled studies. Cite this article: Bone Jt Open 2023;4(10):791–800


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1047 - 1051
1 Sep 2022
Balato G Dall’Anese R Balboni F Ascione T Pezzati P Bartolini G Quercioli M Baldini A

Aims. The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid. Methods. Between October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy. Results. The AUC was 0.99 (95% confidence interval (CI) 0.98 to 1.00). Receiver operating characteristic (ROC) analysis showed that the optimal cut-off value of synovial fluid alpha-defensin was 1.0 μg/l. The sensitivity of alpha-defensin was 100% (95% CI 96 to 100), the specificity was 97% (95% CI 90 to 98), the positive predictive value was 89.2% (95% CI 82 to 94), and negative predictive value was 100% (95% CI 96 to 100). ROC analysis demonstrated an AUC of 0.99 (95% CI 0.98 to 1.0). Conclusion. The present study confirms the utility of alpha-defensin in the synovial fluid in patients with painful TKA to select cases of PJI. Since LC-MS is still a time-consuming technology and is available in highly specialized laboratories, further translational research studies are needed to take this evidence into routine procedures and promote a new diagnostic approach. Cite this article: Bone Joint J 2022;104-B(9):1047–1051


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims. Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment. Methods. A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019. Results. Mean overall patient satisfaction for the entire cohort was 4.7 (SE 0.1) on a 5-point Likert scale, with 93% being either very satisfied or satisfied compared with a Likert of 4.3 and patient satisfaction of 81% in the mechanical alignment group (p < 0.001 and p < 0.006 respectively). At mean follow-up of 17 months (11 to 27), the mean overall Likert, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten Joint Score, and Knee Society Knee and Function Scores were significantly better in the kinematic group than in the neutral mechanical alignment group. The most common complication in both groups was contracture requiring manipulation under anaesthesia, involving seven knees (6.1%) in the kinematic group and nine knees (7.8%) in the mechanical alignment group. Conclusion. With the advent of advanced technology, and the ability to obtain accurate bone cuts, the target limb alignment, and soft-tissue balance within millimetres, using a restricted kinematic alignment concept demonstrated excellent patient satisfaction following primary TKA. Longer-term analysis is required as to the durability of this method. Cite this article: Bone Joint J 2021;103-B(6 Supple A):59–66


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 30 - 30
7 Aug 2023
Mayne A Rajgor H Munasinghe C Agrawal Y Pagkalos I Davis E Sharma A
Full Access

Abstract. Introduction. There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty - The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using intra-operative bony registration). The Mako knee system is an image-based system (using a pre-operative CT scan). This study aimed to compare surgical accuracy between the ROSA and Mako systems with specific reference to Joint Line Height, Patella Height and Posterior Condylar Offset. Methodology. This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive ROSA TKAs and the initial 50 consecutive Mako TKAs performed by two high volume surgeons. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph. Patella height was assessed using the Insall-Salvati ratio. Results. There was no significant difference between ROSA TKA and Mako TKA with regards to restoration of joint line height, ROSA mean 0.2mm versus Mako mean 0.3mm (p<0.05), posterior condylar offset, ROSA mean 0.16mm versus Mako mean 0.3mm (p<0.05), and patella height, ROSA mean 0.02 versus Mako mean 0.03 (p<0.05). Conclusion. This study is the first study to compare the accuracy of the ROSA and MAKO knee systems in total knee arthroplasty. Both systems are highly accurate in restoring native posterior condylar offset, joint line height, and patella height in TKA with no significant difference demonstrated between the two robotic systems


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 74 - 74
7 Aug 2023
Alabdullah M Liu A Xie S
Full Access

Abstract. Rehabilitation exercise is critical for patients’ recovery after knee injury or post-surgery. Unfortunately, adherence to exercise is low due to a lack of positive feedback and poor self-motivation. Therefore, it is crucial to monitor their progress and provide supervision. Inertial measurement unit (IMUs) based sensing technology can provide remote patient monitoring functions. However, most current solutions only measure the range of knee motion in one degree of freedom. The current IMUs estimate the orientation-angle based on the integrated raw data, which might lack accuracy in measuring knee motion. This study aims to develop an IMU-based sensing system using the absolute measured orientation-angle to provide more accurate comprehensive monitoring by measuring the knee rotational angles. An IMU sensing system monitoring the knee joint angles, flexion/extension (FE), adduction/abduction (AA), and internal/external (IE) was developed. The accuracy and reliability of FE measurements were validated in human participants during squat exercise using measures including root mean square error (RMSE) and correlation coefficient. The RMSE of the three knee angles (FE, AA, and IE) were 0.82°, 0.26°, and 0.11°, which are acceptable for assessing knee motion. The FE measurement was validated in human participants and showed excellent accuracy (correlation coefficient of 0.99°). Further validation of AA and IE in human participants is underway. The sensing system showed the capability to estimate three knee rotation angles (FE, AA, and IE). It showed the potential to provide comprehensive continuous monitoring for knee rehabilitation exercises, which can also be used as a clinical assessment tool


Abstract. Introduction. Transforming outpatient services is a key commitment set out in the NHS Long Term Plan, with particular emphasis on digital solutions to reduce outpatient follow-up (FU) by 25%. This study looks at the potential for removing knee arthroscopy FU by providing a bespoke multimedia report for each individual patient, generated using the Synergy™ Surgeon App (Arthrex). Methodology. Single District Hospital using a 3 Phase study. Phase 1 – Assessment of cost and environmental impact of outpatient follow up appointments. Phase 2 – Bench marking of existing pathways and patient experience. Phase 3 – Qualitative assessment of multimedia report feedback of 30 patients. Results. Phase 1 – Impact per year for Trust in released clinician time 135hrs. Cost avoidance £40-£60k. Reduction of the carbon footprint from reduced FU of 3132 KgCo2e2. Phase 2 – Deep dive on 2019 n. 353 procedures. 1206 outpatient appointments required. Average 1.2 post-operative appointments. Phase 3 – 87% of patients who received the e-op report needed no further FU. This compares to only 25% using a traditional post op discussion after surgery. 94% of patients felt the report aided their recovery. Conclusions. Reducing patient FU appointments is crucial to the future of the NHS. Achieving this whilst simultaneously improving the quality of patient communication is achievable as this study has demonstrated. The potential scalability of this project to be applied other arthroscopic procedures is enormous. The study has demonstrated patients are comfortable with modern technology and feel it enhances their understanding whilst decreasing the need for routine post-op FU


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 8 - 8
7 Aug 2023
Kaka A Shah A Yunus A Patel A Patel A
Full Access

Abstract. Introduction. Challenges in surgical training have led to the exploration of technologies such as augmented reality (AR), which present novel approaches to teaching orthopaedic procedures to medical students. The aim of this double-blinded randomised-controlled trial was to compare the validity and training effect of AR to traditional teaching on medical students’ understanding of total knee arthroplasty (TKA). Methodology. Twenty medical students from 7 UK universities were randomised equally to either intervention or control groups. The control received a consultant-led teaching session and the intervention received training via Microsoft HoloLens, where surgeons were able to project virtual information over physical objects. Participants completed written knowledge and practical exams which were assessed by 2 orthopaedic consultants. Training superiority was established via 4 quantitative outcome measures: OSATS scores, a checklist of TKA-specific steps, procedural time, and written exam scores. Qualitative feedback was evaluated using a 5-point Likert scale. Results. AR training was superior in teaching basic technical proficiency and understanding of TKA, with the intervention group significantly outperforming the control group in 3 metrics [OSATS (38.6%, p=0.021), checklist (33%, p=0.011) and written exam (54.5%, p=0.001)]. Procedural time was equivalent between cohorts (p=0.082). AR was rated as significantly more enjoyable (p=0.044), realistic (p=0.003), easy to understand (p=0.040), and proficient in teaching (p=0.02). Conclusion. In this adequately powered, double-blinded randomised-controlled trial, AR training demonstrated substantially improved translational technical skills and knowledge needed to understand TKA over traditional learning in medical students. Additionally, the results showed face, content, and transfer validity for AR in surgical training


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1202 - 1208
1 Nov 2022
Klasan A Rice DA Kluger MT Borotkanics R McNair PJ Lewis GN Young SW

Aims. Despite new technologies for total knee arthroplasty (TKA), approximately 20% of patients are dissatisfied. A major reason for dissatisfaction and revision surgery after TKA is persistent pain. The radiological grade of osteoarthritis (OA) preoperatively has been investigated as a predictor of the outcome after TKA, with conflicting results. The aim of this study was to determine if there is a difference in the intensity of pain 12 months after TKA in relation to the preoperative radiological grade of OA alone, and the combination of the intensity of preoperative pain and radiological grade of OA. Methods. The preoperative data of 300 patients who underwent primary TKA were collected, including clinical information (age, sex, preoperative pain), psychological variables (depression, anxiety, pain catastrophizing, anticipated pain), and quantitative sensory testing (temporal summation, pressure pain thresholds, conditioned pain modulation). The preoperative radiological severity of OA was graded according to the Kellgren-Lawrence (KL) classification. Persistent pain in the knee was recorded 12 months postoperatively. Generalized linear models explored differences in postoperative pain according to the KL grade, and combined preoperative pain and KL grade. Relative risk models explored which preoperative variables were associated with the high preoperative pain/low KL grade group. Results. Pain 12 months after TKA was not associated with the preoperative KL grade alone. Significantly increased pain 12 months after TKA was found in patients with a combination of high preoperative pain and a low KL grade (p = 0.012). Patients in this group were significantly more likely to be male, younger, and have higher preoperative pain catastrophizing, higher depression, and lower anxiety (all p ≤ 0.05). Conclusion. Combined high preoperative pain and low radiological grade of OA, but not the radiological grade alone, was associated with a higher intensity of pain 12 months after primary TKA. This group may have a more complex cause of pain that requires additional psychological interventions in order to optimize the outcome of TKA. Cite this article: Bone Joint J 2022;104-B(11):1202–1208


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 11 - 11
1 Jul 2022
Baker P Martin R Clark N Nagalingham P Hackett R Danjoux G McCarthy S Gray J
Full Access

Abstract. Introduction. The NHS long term plan endorses ‘personalised’, ‘digitally enabled’, ‘out of hospital’ care. Multiagency guidance (CPOC(2021)/NICE(2021)/GIRFT(2021)/NHSX(2021)) advocates an integrated ‘pathway’ approach to information sharing, shared-decision making and patient support. Digital solutions are the vehicle to deliver these agendas. Methods. In 2018 we developed a digital joint pathway (DJP) spanning the surgical care pathway (prehabilitation to rehabilitation) using the GoWellHealth platform. Patients listed for joint replacement are offered the DJP as routine care. Activity and engagement are monitored using the DJP data library. We sought to evidence our DJP by assessing patient engagement, experience and outcomes (OKS/EQ5D/Readmission). Results. Engagement. Consecutive cohort of the first 1195 patients registered. Activation rates were >85% and >70% viewed content within the DJP (median=15 access/pt; mean=83 minutes on DJP/pt). Engagement was similar irrespective of age and gender (p=NS). Older patients preferred to access via a computer. Experience. Qualitative interviews (n=14) demonstrated patients felt the DJP impacted positively on their health behaviours and contributed to their recovery. They spoke positively about the use of technology and the accessibility of the DJP. Outcomes. Comparison of patients on the DJP versus those not on the DJP using adjusted regression models demonstrated improved EQ5D=0.070 (95%CI=0.004-0.135,p=0.04), OKS=5.0 (95%CI=2.2-7.8,p<0.001) and readmission rates (3.6% versus 5.6%,p<0.01) for DJP patients. Conclusions. A DJP model for information delivery and patient support, across the entirety of the surgical pathway, is feasible and demonstrates high levels of patient engagement, experience and improved patient outcomes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 48 - 48
1 Jul 2022
Blucher N Fletcher J Platt N Porteous A
Full Access

Abstract. Introduction. Controversy exists regarding the optimal tibial coronal alignment in total knee arthroplasty. Many believe navigation or robotics are required to set kinematic alignments or to ensure they remain within ‘safe’ limits e.g. maximum 5° varus on the tibia. Given most navigation or robotic systems require the surgeon to identify the ankle malleoli, this study aimed to radiographically analyse standardly used intra-operative landmarks around the ankle, assessing their value in achieving kinematic alignment / setting safety boundaries. Materials and Methods. Long leg alignment radiographs were analysed independently by two orthopaedic surgeons at two time points, eight weeks apart. Angles were measured between the long axis of the tibia (TB) and: 1. lateral malleolus (TB-LM), 2. lateral border of the talus (TB-LT) and 3. medial aspect of the medial malleolus (TB-MM). Intra- and inter-rater reliabilities were assessed. Results. One hundred and sixty-seven radiographs in 119 patients were analysed; mean age 71.6 years. Mean angles (95% CI) were: TB-LM 4.8° (4.7°- 4.8°), TB-LT 2.6° (2.5° - 2.6°) and TB-MM 4.2° (4.1° - 4.2°). Interrater reliability was good for TB-LM (ICC = 0.72) and TB-MM (ICC=0.67), and fair for TB-LT (ICC= 0.50). Intra-rater reliability was excellent for all measures (ICC >0.85). Conclusion. There are consistent angles between tibial alignment and ankle landmarks. Using these landmarks, with standard instrumentation and alignment checks, allows surgeons to define safe limits, e.g. maximum 4.8° tibial varus if aligned to the tip of the lateral malleolus or set a 2.5° varus cut, without the need for added technology


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 72 - 72
1 Oct 2018
O'Connor MI Blau B
Full Access

Introduction. Pressure to control health care costs may limit the ability of new implants to enter the market. Customized individually made (CIM) knee implants are produced from CT scans of each patient and may result in improved clinical outcomes based on early data showing less blood loss, reduced bone resection, and better implant function and alignment. Limited economic evidence suggests that the use of CIM technology may result in cost savings, particularly when post-discharge expenses are included. The purpose of this study was to evaluate real-world cost data to determine episode spending in a Medicare population receiving either CIM or off-the-shelf (OTS) implants. Methods. The Yale Center for Musculoskeletal Care and Baker Tilly Healthcare Management reviewed episode expenditures among Medicare beneficiaries who received CIM and OTS implants for TKA between 01/01/2015 and 12/31/2015. Episode costs included the pre-operative CT scan, index TKA procedure, and 12-month post-index spending for inpatient (IP), outpatient (OP), emergency room (ER), skilled nursing facility (SNF), and home health (HH) services. CIM patients were identified through a matching process utilizing de-identified patient demographic and procedural information and the presence of a CT scan 28–365 days before index. OTS patients included those without a CT scan within one year of index. CIM and OTS cohorts were propensity matched to produce comparable cohorts at a one-to-five ratio based on age range, gender, race, geographical location, and comorbidities. Average expenditure was used to calculate one-year costs of care differences between the CIM and the OTS technologies. A Generalized Linear Model (GLM) and two-part model (logistics and GLM) were used to test statistical significance. Results. The study included 4,434 patients (CIM: 739, OTS: 3,695). CIM index hospital expenses were 6.5% less than OTS (CIM: $11,579; OTS: $12,386, p<0.0001). CIM patients were 37.5% less likely to incur SNF costs than OTS patients (CIM: 3.0% vs. OTS: 4.8%; p=0.0241) and had 45.1% lower average SNF expenditures (CIM: $8,882 vs. OTS: $16,183; p=0.0236). There was no difference in the probability of incurring post-index IP costs (CIM: 15.7% vs. OTS: 15.4%; p=0.9437) but average post-index IP expenditures were 27.2% lower among the CIM cohort than OTS (CIM: $12,817 vs. OTS: $17,605; p=0.0008). However, CIM patients were 10.5% more likely to incur OP costs (CIM: 90.9% vs. OTS: 85.7%; p=0.0005) and had 6.1% higher average OP expenditures (CIM: $2,328 vs. OTS: $2,106; p=0.0377). Average 12-month episode spending for the CIM cohort was 8.4% less than the OTS cohort ($1,697 Difference; CIM: $18,585 vs. OTS: $20,280; p<0.0001). Conclusion. Study findings demonstrate that the use of CIM technology can result in significant 12-month episode savings among a Medicare population. The average expenditure differences noted for post-index IP, SNF, and OP cost categories suggest there are differences in required post-operative treatment across the two cohorts. Savings calculated in the analysis is a meaningful reduction for payers. Providers may also benefit from index and episode cost savings through shared savings arrangements. CIM technology should be considered as a method to reduce TKA episode spending


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims. A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation. Methods. This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded. Results. There were 194 patients in the control group, 103 in group 1, and 74 in group 2. There were no significant differences in baseline demographics between the groups. Patients in group 2 had significantly higher baseline mental health subscores than control and group 1 patients (53.2 vs 50.2 vs 50.2, p = 0.041). There were no significant differences in any PROMs at six weeks or 12 months postoperatively (p > 0.05). There was no difference in the rate of manipulation under anaesthesia (MUA), complication rates, postoperative ROM, or blood loss. There were fewer mechanical axis outliers in groups 1 and 2 (25.2%, 14.9% respectively) versus control (28.4%), but this was not statistically significant (p = 0.10). Conclusion. The sequential addition of navigation of the distal femoral cut and sensor-guided ligament balancing did not improve short-term PROMs, radiological outcomes, or complication rates compared with conventional techniques. The costs of these added technologies may not be justified. Cite this article: Bone Joint J 2020;102-B(6 Supple A):24–30


Bone & Joint Open
Vol. 1, Issue 2 | Pages 8 - 12
18 Feb 2020
Bhimani SJ Bhimani R Smith A Eccles C Smith L Malkani A

Aims. Robotic-assisted total knee arthroplasty (RA-TKA) has been introduced to provide accurate bone cuts and help achieve the target knee alignment, along with symmetric gap balancing. The purpose of this study was to determine if any early clinical benefits could be realized following TKA using robotic-assisted technology. Methods. In all, 140 consecutive patients undergoing RA-TKA and 127 consecutive patients undergoing conventional TKA with minimum six-week follow-up were reviewed. Differences in visual analogue scores (VAS) for pain at rest and with activity, postoperative opiate usage, and length of stay (LOS) between the RA-TKA and conventional TKA groups were compared. Results. Patients undergoing RA-TKA had lower average VAS pain scores at rest (p = 0.001) and with activity (p = 0.03) at two weeks following the index procedure. At the six-week interval, the RA-TKA group had lower VAS pain scores with rest (p = 0.03) and with activity (p = 0.02), and required 3.2 mg less morphine equivalents per day relative to the conventional group (p < 0.001). At six weeks, a significantly greater number of patients in the RA-TKA group were free of opioid use compared to the conventional TKA group; 70.7% vs 57.0% (p = 0.02). Patients in the RA-TKA group had a shorter LOS; 1.9 days versus 2.3 days (p < 0.001), and also had a greater percentage of patient discharged on postoperative day one; 41.3% vs 20.5% (p < 0.001). Conclusion. Patients undergoing RA-TKA had lower pain levels at both rest and with activity, required less opioid medication, and had a shorter LOS