761 cases in 613 patients with minimal two years follow-up had both metal ion levels and quality pelvis X-ray identified in our database and are included in this study. The UCLA activity score, femoral shaft angle, body mass index, weight, American Society of Anesthesiologists (ASA) score, combined range of motion (CROM), diagnosis, age, implant brand, gender, AIA, bearing size, and duration of implantation were analyzed to determine the potential risk factors for elevated metal ion levels with use of uni- and multi-variable logistic regression models. A safe zone for hip resurfacing (RAIL: Relative Acetabular Inclination Limit) was calculated based on implant size and AIA on AP pelvis X-ray. For AIA below the RAIL, there were no adverse wear failures or dislocations, and only 1% of cases with ion levels above 10 μg/L. We have not found a lower limit of AIA where failures occurred. Other than high inclination angle and small bearing size, female gender was the only other factor that correlated with high ion levels in the multivariate analysis. We have described the robust “safe zone” for
Introduction. Pelvic flexion and extension in different body positions can affect acetabular orientation after total hip arthroplasty, and this may predispose patients to dislocation. The purpose of this study was to evaluate functional
Introduction.
Abstract. Optimal
In 2021, Vigdorchik et al. published a large multicentre study validating their simple Hip-Spine Classification for determining patient-specific
Acetabular cup positioning remains a real challenge and component malpositioning after total hip arthroplasty (THA) can lead to increased rates of dislocation and wear. It is a common cause for revision THA. A novel 3D imageless mini-optical navigation system was used during THA to provide accurate, intraoperative, real-time, and non-fluoroscopic data including component positioning to the surgeon. This retrospective comparative single surgeon and single approach study examined
Background:. Numerous studies have reported the importance of
Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in (THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve
Background. Supine positioning during direct anterior approach total hip arthroplasty (DAA THA) facilitates use of fluoroscopy, which has been shown to improve
Introduction.
Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve
The purpose of this study is to assess the accuracy of component positioning and incidence of peri-operative and 90-day post-operative complications following robotic arm-assisted and conventional total hip arthroplasty (THA). Three groups of patients were analyzed for this study: those that underwent conventional THA performed by Surgeon 1, conventional THA performed by Surgeon 2, or robotic arm-assisted THA performed by Surgeon 2. All patients underwent primary uncemented THA via a posterior approach. Patient characteristics, intra-operative data, and 90-day post-operative complications were collected. Post-operative standing pelvic radiographs were utilized to measure acetabular position and to identify post-operative complications.
Introduction. The longevity of total hip arthroplasty (THA) is dependent on
Introduction. Total hip arthroplasty is considered to be one of the most successful orthopaedic interventions.
Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even for experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus has not been widely adopted. Another method to improve
Problem. Total hip replacement (THA) is among the most common and highest total spend elective operations in the United States. However, up to 7% of patients have 90-day complications after surgery, most frequently joint dislocation that is related to poor
Background. Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of
Total hip replacement is among the most successful interventions in medicine and has been termed “The Operation of the Century”. Most major problems have been solved including femoral fixation, acetabular fixation, and wear. With a success rate of over 95% at 10 years in both hip and knee arthroplasty in a number of studies, the question remains as to whether the current status quo is optimal or acceptable. The literature, however, reports are from centers that represent optimised results and registry data, including the Medicare database, indicates that substantial short-term problems persist. The major issue is the variability in the performance of the procedure. The inability to consistently position components, particularly the acetabular component, results in major problems including instability and limb length discrepancy. A report by Malchau, et al. reveals that even among the best surgeons, optimal
Background. Several recent reports have documented high frequency of malpositioned acetabular components, even amongst high volume arthroplasty surgeons. Robotic assisted total hip arthroplasty (THA) has the potential to improve component positioning; however, to our knowledge there are no reports examining the learning curve during the adoption of robotic assisted THA. Purpose. The purpose of this study was to examine the learning curve of robotic assisted THA as measured by component position, operative time, intra-operative technical problems, and complications. Methods. The first 105 robotic-assisted THAs performed by a single surgeon with a posterior approach from June 2011 to August 2013 patients were divided into three groups based on the order of surgery. Group A was cases 1–35, group B 36–70 and group C 71–105. Component position, operative time, intra-operative technical problems, and intra-operative complications were recorded. Results. There was no significant difference between groups A, B, and C for BMI or age (Figure 1). Gender was different between groups with 20 males in group A, 9 in group B, and 16 in group C (p < 0.05). There was no difference for mean acetabular inclination, acetabular anteversion, or leg length discrepancy between groups as experience increased (p > 0.05) (Figure 2). The average operative time for groups A, B, and C was 79.8 ± 27 min, 63.2 ± 14.2 min, and 69.4 ± 16.3 min respectively (p = 0.02). The cumulative number of outliers was two for the Lewenick safe zone and six for the Callanan safe zone. Figure 3 displays
Introduction. The acetabular cup should be properly oriented to prevent dislocation and to reduce wear and leg length discrepancy. Despite advances in surgical techniques and instrumentation, achieving proper cup placement in total hip arthroplasty (THA) is challenging with potentially large variations of cup position and limited accuracy. We evaluated whether cup placement on anatomical location ensured original center of rotation (COR) and surgeon's experiences of THA reduced variations in