Introduction. Enhanced pain and rehabilitation protocols have significantly improved patient recovery following primary TKR. Little has been written on how the protocols have affected the revision TKR patient. We report on a matched group of revision and primary TKR patients treated with the identical pain and rehab program. Materials and Methods. 40 aseptic RTKR patients who underwent a full femoral and tibial revision were matched by age, sex, and BMI to a group of patients who underwent a cemented tri-compartmental primary TKR. All revision knees had uncemented stemmed femurs and tibias. All 40 patients had either a metaphyseal sleeve on either the femur or tibia or both. Patients in both groups were treated with an identical post op pain protocol (Spinal anesthetic, local infiltrative analgesia and multimodal oral pain management along with rapid rehabilitation). All patients were mobilized on POD1 and allowed weight bearing as tolerated. Patients were followed for a minimum of 1 year. KSS at 6 weeks and 1 year were recorded for both groups. Results. There was no significant difference in length of stay between the RTKR and the primary TKR (1.2 days versus 1.1 days). Average oral morphine equivalents used during the hospitalization was 38 for the RTKR and 42 for the primary group. There was 1 readmission in each group: GI distress in the RTKR and urinary retention in the primary group. There no were reoperations, wound healing problems, identified thromboembolic events or manipulations under anesthesia in either group. KSS for the RTKR group averaged 87.3 at 6 weeks (range 45 to 99) and 89.1at minimum 1 year (range 52 to100). KSS for the primary group averaged 89.9 (range 71 to 100) at 6 week follow-up and 93.2 (range 54 to 100) at minimum follow-up. Range of motion at final follow up averaged1.2 (0–10) to 114.1 (55–135) for the RTKR group and 1 (0–8) to 121.3 (85–140) for the primary group. Conclusion. Despite more complex surgery in the revision
Introduction. One of the main considerations in the revision TKR setting is deciding on the level of constraint to be utilized once the bone defects have been reconstructed. There is a fear that employing a maximally constrained insert could compromise long term results. We report on a consecutive series of full tibial and femoral component revisions all treated with a maximally conforming insert and followed for a minimum of 5 years. Materials and Methods. The study group consisted of 76 consecutive revision TKR in 76 patients where both the femur and the tibia were revised. 4 patients died and 6 were lost to follow up. Final cohort had an average age of 70 years, average BMI of 31 and there were 39 males in the group. Average time to revision was 7 years (range 1–10 years) and the reasons for revision included infection in 28, aseptic loosening 26, osteolysis and poly wear in 9 and 13 other. All were treated with the same revision system and an identical maximally conforming tibial rotating platform insert and followed for an average of 7 years (range 5–14 years). Results. one patient required additional surgery during the study period for a patella fracture. There were no manipulations. Average Knee Society Scores increased from an average of 55 to 89 at final follow up. No implants were loose or at risk of loosening and no knee sustained any mechanical complications related to the insert. Conclusion. Despite fears to the contrary, we did not identify any issues in using a maximally constrained insert in this consecutive group of revision
There are a wide variety of implant brands and types of knee replacement available to surgeons. With time, the options available within many implant brand portfolios has grown, with alternative tibial or femoral components, tibial insert materials or shapes and patella resurfacings. To investigate the effect of the expansion of implant brand portfolios, and to establish the potential numbers of compatible implant construct combinations.Abstract
Introduction
Aim
With respect to survivorship following total knee arthroplasty (TKA), joint registries consistently demonstrate higher revision rates for both sexes in those less than 55 years. The current study analyses the survivorship of 500 cementless TKAs performed in this age group in a high-volume primary joint unit where cementless TKA has traditionally been used for the majority of patients. This was a retrospective review of 500 consecutive TKAs performed in patients under the age of 55 between March 1994 and April 2017. The primary outcome measure for the study was all-cause revision. Secondary outcome measures included clinical, functional and radiological outcomes.Abstract
Introduction
Methods
The Centers for Medicare and Medicaid Services (CMS) removed total knee arthroplasty (TKA) from inpatient-only status in 2018. Our goal was to measure the adoption of outpatient TKAs, the impact on re-treatment rates, and the economic implications for hospitals. We utilized 100% national Medicare Part A fee-for-service (FFS) patient-level claims data for 2017–2018. We excluded DRG 469 TKAs since they are unlikely to be outpatient candidates, which left 257,107 primary TKAs in 2017 and 264,393 in 2018. We examined the time trend in monthly case volume and 30-day retreatment rate (defined as percent of patients having a second TKA within 30 days of the first. We calculated the loss in revenue for a hospital by multiplying the decrease in payment rate between inpatient and outpatient by the outpatient and total 2018 TKA volume.Introduction
Methods
Revision total knee arthroplasty (rTKA) accounts for approximately 5% to 10% of all TKAs. Although the complexity of these procedures is well recognized, few investigators have evaluated the cost and value-added with the implementation of a dedicated revision arthroplasty service. The aim of the present study is to compare and contrast surgeon productivity in several differing models of activity. All patients that underwent primary or revision TKA from January 2016 to June 2018 were included as the primary source of data. All rTKA patients were categorized by the number of components revised (e.g. liner exchange, two or more components). Three models were used to assess the potential surgical productivity of a dedicated rTKA service : 1) work relative value unit (RVU) Aims
Materials and Methods
The rate of day-case total knee replacement (TKR) in the UK is currently ~0.5%. Reducing length of stay improves efficiency, increases operative throughput and tackles the rising demand for joint replacement surgery and the COVID-19 related backlog. We report safe delivery of day-case TKR in an NHS Trust via inpatient wards, with no additional resources. Day-case TKRs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six-months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction.Abstract
Introduction
Methodology
Objectives. Our study aimed to examine if a mobile-bearing
Pitting damage on implants has been reported and attributed to use of electrocautery. This study aimed to distinguish how different TKA bearing surfaces are susceptible to this type of damage and whether surgeons were aware that this damage can occur. A survey was sent to Hip and Knee Society members to determine what percentage of adult reconstructive surgeons use electrocautery after implantation of components. Three bearing surfaces for primary TKA were selected: CoCr, Oxinium, and zirconium nitride (ZrN) to be damaged by electrocautery with a monopolar (MP, Bovie) and bipolar (BP, Aquamantys) electrocautery with three different energy settings. A comparison of surface damage and backscatter elemental analysis using SEM was performed. Average roughness (Ra), maximal peak-to-valley height (Rz,), kurtosis (Rk), and skewness (Rsk) measurements were collected using a profilometer (DektakXT, Bruker, Tucson, AZ) with a 2.5µm radius stylus to assess an area of 3.8mm by 3.2mm in the central portion of the area for each MP and BP energy setting used to impart damage to the bearing surfaces. A similar undamaged area for each bearing surface was also measured for roughness parameter comparison.Introduction
Methods
Introduction. Unicondylar knee replacements (UKR) may be more effective compared to Total knee replacements (TKR) in unicompartmental arthritis. We report patient outcomes & satisfaction data in an age matched cohort of patients with either a UKR or TKR. Method. A single unit and single surgeon series of patients were recruited. Data was retrospectively collated for 68 patients with more than 24 months follow-up. UKR was undertaken in patients with isolated medial compartment osteoarthritis; stable ACL and less than grade 3 lateral patellar changes of the Outerbridge classification. TKR was undertaken for the rest. The patients were assessed with validated knee scores including the
Diagnosing acute postoperative periprosthetic joint infections (PJIs) after primary total knee arthroplasties (TKAs) remains difficult. Published diagnostic thresholds for ESR, CRP, and synovial fluid analysis have not been replicated. We aimed to validate the optimal cutoffs for detecting acute postoperative PJIs in a large series of primary TKAs. We retrospectively identified 27,066 primary TKAs performed between 2000–2019. Within 12 weeks, 171 knees (170 patients) had a synovial fluid aspiration. Patients were divided into two groups: evaluation <6 weeks or 6–12 weeks. The 2011 MSIS criteria for PJI diagnosed infection in 22 knees. Mann-Whitney U tests compared medians; ROC analyses determined optimal thresholds. Mean follow-up was 5 years.Introduction
Methods
Although the vast majority of patients that undergo
total knee replacement have satisfactory outcomes with a generally
low complication rate, occasionally a patient will be encountered
that has had multiple failed surgeries, and now reaches a crossroad
as to whether limb salvage will be acceptable or not. Cite this article:
Pseudotumor or high grade ALVAL (aseptic lymphocyte-dominated vasculitis-associated lesion) development around total hip replacements secondary to local metal debris generation – especially in the setting of metal-on-metal bearings – is a well-recognised histopathologic phenomenon. Recent work has suggested a strong genetic correlation with an individual's risk of such lesion development following metal exposure. Emerging data have highlighted a similar potential concern around total knee replacements (TKRs), particularly with increasing construct modularity. To date, the body-of-knowledge pertaining to TKR-associated ALVALs has largely been limited to individual case reports or small retrospective case series’, with no large-scale investigation looking at this potential complication. This study sought to establish the preliminary prevalence of pseudotumor or high grade ALVAL formation seen at the revision of primary TKRs and to establish the correlation between histologic ALVAL grade and patient-reported functional outcomes. Findings of 1263 consecutive patients undergoing revision knee surgery, at a high-volume referral center, were reviewed. 161 cases of active infection were excluded. Complete histopathology reports were subsequently available for 321 (29.1%) non-infective cases. Each case was independently histologically-classified using a previously validated scoring system reflecting ALVAL grade. Post-operative patient-reported outcomes measures (PROMs) were available for 134 patients (41.7%), allowing direct correlation between functional performance and the established histopathology results.Background
Methods
The aim of this prospective multicentre study
was to report the patient satisfaction after total knee replacement (TKR),
undertaken with the aid of intra-operative sensors, and to compare
these results with previous studies. A total of 135 patients undergoing
TKR were included in the study. The soft-tissue balance of each
TKR was quantified intra-operatively by the sensor, and 18 (13%)
were found to be unbalanced. A total of 113 patients (96.7%) in
the balanced group and 15 (82.1%) in the unbalanced group were satisfied
or very satisfied one year post-operatively (p = 0.043). A review of the literature identified no previous study with
a mean level of satisfaction that was greater than the reported
level of satisfaction of the balanced TKR group in this study. Ensuring
soft-tissue balance by using intra-operative sensors during TKR
may improve satisfaction. Cite this article:
Metaphyseal fixation during revision total knee arthroplasties (TKAs) is important, but potentially challenging with historical cone designs. Material and manufacturing innovations have improved the size and shape of cones available, and simplified requisite bone preparation. In a very large series, we assessed implant survivorship, radiographic results, and clinical outcomes of new porous 3-D printed titanium metaphyseal cones featuring a reamer-based system. We reviewed 142 revision TKAs using 202 cones (134 tibial and 68 femoral) from 2015 to 2016. Sixty cases involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. Mean age was 66 years, with 54 % females. Mean BMI was 34 kg/m2. Patients had a mean of 2.4 prior surgeries and 48% had a history of periprosthetic infection. Mean follow-up was 2 years.Introduction
Methods
To investigate the value of tranexamic acid (TA) in reducing blood loss and blood transfusion after TKR and other clinical outcomes such as deep venous thrombosis (DVT), pulmonary embolism (PE), ischaemic heart diseases and mortality. A systematic review and meta-analysis of published randomised and quasi-randomised trials which used TA to reduce blood loss in knee arthroplasty was conducted. The data was evaluated using the generic evaluation tool designed by the Cochrane Bone, Joint and Muscle Trauma Group.Objectives
Methods
Treatment of prosthetic joint infection (PJI) following total knee arthroplasty (TKA) may guided by PJI classification, taking into account infection duration and potential for biofilm formation. Debridement, antibiotics and implant retention (DAIR) is recommended for ‘post-operative’ and ‘acute’ haematogenous PJI. However, the time cut-off for ‘post-operative’ PJI varies across classification systems. Furthermore, poor DAIR success rates have been reported in acute haematogenous PJIs. This study aimed to determine the success of DAIR in a large cohort of PJIs, and assess the utility of current classification systems for predicting DAIR outcomes. In this multicentre retrospective, cohort study, we identified 230 patients undergoing DAIR for first episode PJI following primary TKA. Patient demographics, disease and surgical factors were identified, and PJI subtype, post-operative antibiotic regime and treatment outcomes were recorded. Statistical analysis was performed to identify factors associated with failed DAIR, and success rates were analysed by multiple classification systems using receiver operating characteristic (ROC) curves.Introduction
Method
Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasties (TKAs). However, if the diaphysis has been previously violated (as in revision of a failed stemmed implant), the resultant sclerotic canal can impair cemented stem fixation, which is vital for cone ingrowth and long-term fixation. We report the outcomes of our novel solution to this problem, in which impaction grafting and a cemented stem in the diaphysis was combined with an uncemented metaphyseal cone for revision TKAs with severely compromised bone. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems in a novel fashion for 35 revision TKAs. Mean age at revision TKA was 70 years, with 63% being male. Patients had a mean of 4 prior knee arthroplasty procedures. Indications for the revision with this construct were aseptic loosening (80%) and two-stage re-implantation for periprosthetic infection (PJI; 20%). Mean follow-up was 3 years.Introduction
Methods
Traditional TKR designs exhibit abnormal and unpredictable kinematics: with posterior subluxation in extension and anterior slide with flexion. These can contribute to restricted knee flexion and reduced quadriceps efficiency. Newer designs attempt to provide “guided motion” with the aim of mimicking normal knee kinematics. The Journey (Smith & Nephew) BCS TKR incorporates both an anterior and a posterior cam/post mechanism while Triathlon PS TKR (Stryker) incorporates a posterior cam/post mechanism. This study compares the in-vivo kinematics of these two designs and compares it with normal knee. Knee kinematics of 10 patients with Journey-BCS TKR and 11 patients with Triathlon PS TKR; all with excellent clinical outcome (average age: 65) were analysed. Patients underwent fluoroscopic assessment of the knee during a step-up and deep knee bend exercise. 2D fluoroscopic images were recorded. Data was analysed for patella tendon angle (PTA) and contact points using a 3D model fitting technique. This data was compared to normal knee kinematics (n=20).Introduction
Methods
We retrospectively reviewed the records of 1150
computer-assisted total knee replacements and analysed the clinical
and radiological outcomes of 45 knees that had arthritis with a
pre-operative recurvatum deformity. The mean pre-operative hyperextension
deformity of 11° (6° to 15°), as measured by navigation at the start
of the operation, improved to a mean flexion deformity of 3.1° (0°
to 7°) post-operatively. A total of 41 knees (91%) were managed
using inserts ≤ 12.5 mm thick, and none had mediolateral laxity
>
2 mm from a mechanical axis of 0° at the end of the surgery. At
a mean follow-up of 26.4 months (13 to 48) there was significant
improvement in the mean Knee Society, Oxford knee and Western Ontario
and McMaster Universities Osteoarthritis Index scores compared with
the pre-operative values. The mean knee flexion improved from 105°
(80° to 125°) pre-operatively to 131° (120° to 145°), and none of
the limbs had recurrent recurvatum. These early results show that total knee replacement using computer
navigation and an algorithmic approach for arthritic knees with
a recurvatum deformity can give excellent radiological and functional
outcomes without recurrent deformity.