There is conflicting evidence about the merits
of mobile bearings in total knee replacement, partly because most randomised
controlled trials (RCTs) have not been adequately powered. We report
the results of a multicentre RCT of mobile There was no significant difference between the groups pre-operatively:
mean OKS was 17.18 ( In this appropriately powered RCT, over the first five years
after total knee replacement functional outcomes, re-operation rates
and healthcare costs appear to be the same irrespective of whether
a mobile or fixed bearing is used. Cite this article:
There is conflicting evidence about the merits of using mobile bearings at total knee replacement (TKR), partly because most randomised controlled trials (RCTs) have not been adequately powered. A pragmatic multicentre RCT involving 116 surgeons in 34 UK centres was begun in 1999. Within a partial factorial design, 539 patients were randomly allocated to mobile or fixed bearings. The primary outcome measure was the Oxford Knee Score (OKS); secondary measures included SF-12, EQ-5D, costs, cost-effectiveness and need for further surgery.Introduction
Methods
129 knees suitable for a standard PCL retaining cemented total knee replacement were randomised into two groups, one in which PCL was retained in the normal way, the other group having the PCL fully resected. Both groups received a PCL retaining implant. The two groups were well matched with a predominance of females and a mean age of 67 years. There was no statistically significant difference in the HSS scores at an average of 57 months (range 56–60 months) in the two groups. Pain relief, deformity correction, range of motion, stability and strength were comparable in the two groups. A radiological assessment revealed femoral rollback in approximately 20% of cases with a slightly higher incidence in the PCL sacrificed group. There was no significant loosening detected in either of the categories at two years review. At five years one TKR in the PCL retained group has been revised due to an infection and one each in the two groups are awaiting revision surgery for loosening. Our findings have shown that there is no significant difference in the 5 year results of a PCL-retaining total knee replacement if the PCL is excised or preserved. This suggests two significant points:
the PCL is not functional in most patients with a total knee replacement even when retained: patients with excised PCLs show good results with PCL retaining implants, thereby questioning the need for posterior stabilised designs in all such cases.
8/39 of revisions were for resurfacing the patella (20%). One patient who had a complex patella fracture needing patellectomy later had further revision surgery for instability requiring posterior stabilised components. In no patient was the revision surgery compromised or made reconstructable due to delayed presentation. In total 3 patients required bone grafting of contained cavities and only 5 knees with aseptic loosening required revision implants with stems.
2 stage revisions of infected knee replacements using a static spacer are complicated by poor patient mobility between stages and the need for extensive soft tissue releases at the second stage. In this study we hypothesised that the use of the resterilsed components as temporary functional spacers, maintains patient function, and reduces soft tissue releases at second stage without reducing the rate of septic failure and obviating the need for expensive purpose made spacers.
We report a prospective study of the feasibility of employing specially trained physiotherapists to screen neonates for congenital dislocation of the hip. During ten years 42,241 babies were screened, using clinical tests; 255 were diagnosed and treated by a Pavlik harness. In the same period 13 children presented late with congenital dislocation of the hip which had not been detected by the screening programme.
Two cases of delayed median nerve division after laceration of the wrist by glass are described. In both there was no neurological damage at the time of the original injury. However, retained fragments of glass were subsequently responsible for division of the median nerve in both cases and of the surrounding tendons in one. Radiographs were an important diagnostic aid in treating the delayed injury.
A 21-year-old female athlete presented with bilateral lumps in her calves which became painful on exercise. Exploration revealed entrapment of the superficial peroneal nerves. Her symptoms were relieved by fasciectomy.
Despite widespread use of gentamicin beads in the treatment of chronic infections of bone and soft tissue, no serious complications have been reported. This report describes a rupture of the femoral vein which occurred during the attempted removal of a chain of beads after radical excision of a chronically discharging Girdlestone arthroplasty. The patient later had a disarticulation at the hip. In the light of our experience with this and other cases we offer some suggestions as to the positioning of gentamicin beads, as well as the timing and method of their extraction.
Fracture separation of the capital femoral epiphysis occurring during attempted closed reduction of a traumatic dislocation of the hip is described in two adolescents. Although this complication is extremely rare, the prognosis of fracture separation with dislocation of the epiphysis is known to be poor. Avascular necrosis subsequently developed in both cases. The importance of gentle manipulative reduction under general anaesthesia with complete muscle relaxation is emphasised.