Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 87 - 87
1 Aug 2020
Gusnowski E Schneider P
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54 degrees of flexion and 60 degrees of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF.

A meta-analysis was performed to directly compare ROM and Disabilities of Arm, Shoulder and Hand (DASH) scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO-OTA distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO-OTA classification or a two-tailed independent samples t-tests for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05.

After rigorous screening, six dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO-OTA classification versus six dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9 degrees, SD 9.3, n=257, volar 61.3 degrees, SD 11.5, n=1906) and extension (dorsal 60 degrees, SD 12, n=257, volar 62.8 degrees, SD 11.4, n=1906) were significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54).

Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5-degrees, which is unlikely to be clinically significant. Additionally, there was no significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 89 - 89
1 Aug 2020
Bourget-Murray J Kendal J Schneider P Montgomery S Kooner S Kubik J Meldrum A Kwong C Gusnowski E Thomas K Fruson L Litowski M Sridharan S You D Purnell J James M Wong M Ludwig T Abbott A Lukenchuk J Benavides B Morrison L
Full Access

Advances in orthopaedic surgery have led to minimally invasive techniques to decrease patient morbidity by minimizing surgical exposure, but also limits direct visualization. This has led to the increased use of intraoperative fluoroscopy for fracture management. Unfortunately, these procedures require the operating surgeon to stay in close proximity to the patient, thus being exposed to radiation scatter. The current National Council on Radiation Protection recommends no more than 50 mSv of radiation exposure to avoid ill-effects. Risks associated with radiation exposure include cataracts, skin, breast and thyroid cancer, and leukemia. Despite radiation protection measures, there is overwhelming evidence of radiation-related diseases in orthopaedic surgeons. The risk of developing cancer (e.g. thyroid carcinoma and breast cancer) is approximately eight times higher than in unexposed workers. Despite this knowledge, there is a paucity of evidence on radiation exposure in orthopaedic surgery residents, therefore the goal of this study is to quantify radiation exposure in orthopaedic surgery residents.

We hypothesize that orthopaedic surgery residents are exposed to a significant amount of radiation throughout their training. We specifically aim to: 1) quantify the amount of radiation exposure throughout a Canadian orthopaedic residency training program and 2) determine the variability in resident radiation exposure by rotation assignment and year of training.

This ongoing prospective cohort study includes all local orthopaedic surgery residents who meet eligibility criteria. Inclusion criteria: 1) adult residents in an orthopaedic surgery residency program. Exclusion criteria: 1) female residents who are pregnant, and 2) residents in a non-surgical year (i.e. leave of absence, research, Masters/PhD). After completion of informed consent, each eligible resident will wear a dosimeter to measure radiation exposure in a standardized fashion. Dosimeters will be worn on standardized lanyards underneath lead protection in their left chest pocket during all surgeries that require radiation protection. Control dosimeters will be worn on the outside of each resident's scrub cap for comparison. Dosimeter readings will then be reported on a monthly and rotational basis. All data will be collected on a pre-developed case report form. All data will be de-identified and stored on a secure electronic database (REDCap). In addition to monthly and rotational dosimeter readings, residents will also report sex, height, level of training, parental status, and age for secondary subgroup analyses. Residents will also report if they have personalized lead or other protective equipment, including lead glasses. Resident compliance with dosimeter use will be measured by self report of >80% use on operative days. Interim analysis will be performed at the 6-month time point and data collection will conclude at the 1 year time point.

Data collection began in July 2018 and interim 6-month results will be available for presentation at the CORA annual meeting in June 2019.

This is the first prospective study quantifying radiation exposure in Canadian orthopaedic residents and the results will provide valuable information for all Canadian orthopaedic training programs.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 105 - 105
1 Jul 2020
Gusnowski E Schneider P Thomas K
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF.

A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO classification or a two-tailed independent samples t-test for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05.

After rigorous screening, 6 dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO classification versus 6 dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9o, SD 9.3, n=257, volar 61.3o, SD 11.5, n=1906) and extension (dorsal 60.0o, SD 12, n=257, volar 62.8o, SD 11.4, n=1906) were statistically significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of AO type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14.01, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54).

Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5o, which is unlikely to be clinically significant. Additionally, we did not find a significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 31 - 31
1 Jul 2020
Lo IKY Bois A LeBlanc J Woodmass J Kwong C Gusnowski E Lo A
Full Access

Rotator cuff disease encompasses a spectrum from partial to full thickness tears. Despite being 2–3 times more common than full–thickness tears, effective non-operative treatment for partial thickness tears has remained elusive. Platelet enriched plasma (PRP) has been proposed to enhance rotator cuff healing by enhancing the natural healing cascade. However, its utility in rotator cuff disease remains controversial. The purpose of this study was to compare the patient reported outcomes between PRP and corticosteroid injection in patients with symptomatic partial thickness tears.

This double blind randomized controlled trial enrolled patients with symptomatic, partial thickness rotator cuff tears or rotator cuff tendinopathy proven on ultrasound or MRI. Patients were randomized to either corticosteroid or PRP ultrasound-guided injection of the affected shoulder. Patients completed patient reported outcomes at 6 weeks and 12 weeks. The primary outcome was Visual Analog Scale (VAS) pain scores. Secondary outcomes included the Western Ontario Rotator Cuff (WORC) index, American Shoulder and Elbow Surgeons (ASES) score, and failure of non-operative management as determined by consent for surgery or progression to operative intervention.

Ninety-nine patients were enrolled in the study with equal demographics between the two groups. Taking into account pre-injection scores, patients with PRP injections demonstrated a statistically significant improvement in VAS scores compared to patients receiving corticosteroid injections at 12 weeks (p=0.045) but not at 6 weeks (p=0.704). There was no difference in other outcome measures or progression of the two groups to surgical intervention.

The use of PRP in the management of partial thickness rotator cuff tears demonstrates significant improvement of pain scores at 12 week follow up compared to corticosteroid injections. However, this did not affect the rate of progression to surgical intervention. Continued study is required to determine the utility of PRP in this patient population.