Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 105 - 105
1 Sep 2012
Pinczewski L Gordon D Sri-Ram K Kok A Linklater J Salmon L
Full Access

Bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been shown to be associated with femoral tunnel widening and cyst formation.

To compare a poly-L-lactide–hydroxyapatite screw (PLLA-HA) with a titanium screw with respect to clinical and radiological outcomes over a 5 year period.

40 patients were equally randomized into 2 groups (PLLA-HA vs titanium) and ACLR performed with a 4 strand hamstring graft with femoral tunnel drilling via the anteromedial portal. Evaluation at 2 and 5 years was performed using the International Knee Documentation Committee assessment (IKDC), Lysholm knee score, KT 1000 arthrometer, single-legged hop test. Magnetic resonance imaging was used to evaluate tunnel and screw volume, ossification around the screws, graft integration and cyst formation.

There was no difference in any clinical outcome measure at 2 or 5 years between the 2 groups. At 2 years, the PLLA-HA femoral tunnel was significantly smaller than the titanium screw tunnel (p=0.015) and at 5 years, there was no difference. At 2 years the femoral PLLA-HA screw was a mean 76% of its original volume and by 5 years, 36%. At 2 years the tibial PLLA-HA screw mean volume was 68% of its original volume and by 5 years, 46%. At 5 years, 88% of femoral tunnels and 56% of tibial tunnels demonstrated a significant ossification response. There was no increase in cyst formation in the PLLA-HA group and no screw breakages.

The PLLA-HA screw provides adequate aperture fixation in ACLR with excellent functional outcomes. It was not associated with femoral tunnel widening or increased cyst formation when compared with the titanium screw. The resorbtion characteristics appear favourable and the hydroxyapatite component of the screw may stimulate osteoconduction, contributing to these results. The PLLA-HA screw is a good alternative to a titanium screw in ACLR, which may aid revision procedures and allow for imaging without artifact.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 126 - 126
1 Sep 2012
Pinczewski L Leys T Kok A Linklater J Salmon L
Full Access

This prospective longitudinal study compares the results of isolated endoscopic ACL reconstruction utilizing 4-strand hamstring tendon (HT) or patellar tendon (PT) autograft over a 15-year period with respect to re-injury, clinical outcomes and the development of osteoarthritis.

90 consecutive patients with isolated ACL rupture were reconstructed with a PT autograft and 90 patients received HT autograft, with an identical surgical technique. Patients were assessed at 2, 5, 7, 10 and 15 years. Assessment included the IKDC Knee Ligament Evaluation including radiographic evaluation, KT1000, Lysholm Knee Score, kneeling pain, and clinical outcomes.

Subjects who received the PT graft had significantly worse outcomes compared to those who received the HT graft at 15 years for the variables of radiologically detectable osteoarthritis (p=0.03), motion loss (p=0.01), single leg hop test (p=0.002), participation in strenuous activity (p=0.05), and kneeling pain (p=0.04). There was no significant difference between the HT and PT groups in overall IKDC grade (p=0.31). ACL graft rupture occurred in 16% of HT group and 8% of the PT group (p=0.07). ACL graft rupture was associated with non-ideal tunnel position (odds ratio 5.0) and males (odds ratio 3.2). Contralateral ACL rupture occurred in significantly more PT patients (24%) than HT patients (12%) (p=0.03), and was associated with age < 18 years (odds ratio 4.1) and the patellar tendon graft (odds ratio 2.6). Radiologically detectable osteoarthritis at 15 years was associated with the PT graft (odds ratio 2.3).

Significant differences have developed in the groups at 15 years after surgery which were not seen at earlier reviews. Compared to the HT Group, the PT group had significantly worse outcomes with respect to radiological osteoarthritis, extension loss and functional tests but no significant difference in laxity was identified. There was a high incidence of ACL injury after reconstruction, to both the reconstructed and the contralateral knee.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 182 - 182
1 May 2012
Pinczewski L Sharma N Salmon L Williams H Roe J Linklater J
Full Access

The results of PLLA screws for ACL reconstruction have demonstrated no significant clinical differences when compared to metallic screws up to two years. However, studies examining PLLA-HA screws are lacking, as are medium term outcomes of bioresorbable screws. This study aims to compare the clinical outcome of ACL reconstruction with a PLLA-HA to a titanium screw, and to assess the extent of resorption of the PLLA-HA screw at two and five years after ACL reconstruction.

Forty patients were randomised to receive either a PLLA-HA or titanium RCI interference screw for ACL reconstruction. Both examiners and patients were blinded to screw type. Patients were prospectively reviewed at 24 and 60 months after surgery with full IKDC assessment, Instrumented Ligament Testing, Lysholm knee score. MRI scans were performed at two and five years following surgery.

Five years after surgery, one patient with a titanium screw had an ACL graft rupture and had undergone revision surgery. Of the remaining 39 patients, 38 (97%) were reviewed at five years. There was no significant difference between the two groups in the volume of the tibial (p=0.89) or femoral (p=0.22) tunnels at five years. Significant screw resorbtion at five years was seen in 77% on the tibial side and 88% on the femoral side in the PLLA group. Good ossification was evident on five year MRI in 94% of the tibial screws and 56% of the femoral screws. In the PLLA-HA group peri tunnel bone marrow oedema was present in 35% of patients on the tibial side and 53% of patients on the femoral side at five years. There was no peri-tunnel bone marrow oedema evident in the titanium group. Peri-graft ganglion cyst was evident on MRI scan on the tibial side in 24% of patients from the PLLA-HA group and 18% of the titanium group (p=0.67). There was no significant difference between the PLLA-HA group and the titanium group on any of the other clinical parameters including IKDC subjective knee score (mean 93), symptoms, range of motion, instrumented ligament laxity (mean 1.8 mm) or overall IKDC grade (90% normal or nearly normal).

ACL reconstruction with PLLA-HA bioabsorbable screws affords comparable clinical and subjective results to titanium screws at five years after surgery. Significant progression of PLLA HA screw resorption occurs between two and five years, with over 75% of screws demonstrating some resorption by five years. However, complete resorption was only evident in a small number of patients. ACL reconstruction with a PLLA HA screw has excellent clinical outcomes and progressive screw resorption and ossification is evident at five years.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 630 - 637
1 May 2012
Bourke HE Gordon DJ Salmon LJ Waller A Linklater J Pinczewski LA

The purpose of this study was to report the outcome of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with ‘isolated’ ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time.

ACL reconstructive surgery in patients with an ‘isolated’ rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis.