Advertisement for orthosearch.org.uk
Results 1 - 50 of 64
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 428 - 432
1 May 1997
Cannegieter DM Juttmann JW

We present a prospective study of the treatment of 32 unstable Colles’ fractures by external fixation and cancellous grafting with minimal exposure. We inserted an external fixator between the radius and the second metacarpal, and maintained ligamentotaxis for five weeks. In 27 patients the result was good or excellent, but five fractures healed with malunion. All patients made a satisfactory functional recovery. At a mean follow-up of three years (1 to 5) after injury none had pain in the wrist and all were satisfied with the result. The average grip strength was 95% of normal. Seven patients had algodystrophy with mild impairment of finger movements in four. We conclude that the combination of cancellous grafting and external fixation is effective for the treatment of unstable Colles’ fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm. 3. ) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 387 - 393
1 Apr 2024
Dean BJF Riley N Little C Sheehan W Gidwani S Brewster M Dhiman P Costa ML

Aims

There is a lack of published evidence relating to the rate of nonunion seen in occult scaphoid fractures, diagnosed only after MRI. This study reports the rate of delayed union and nonunion in a cohort of patients with MRI-detected acute scaphoid fractures.

Methods

This multicentre cohort study at eight centres in the UK included all patients with an acute scaphoid fracture diagnosed on MRI having presented acutely following wrist trauma with normal radiographs. Data were gathered retrospectively for a minimum of 12 months at each centre. The primary outcome measures were the rate of acute surgery, delayed union, and nonunion.


Aims

Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures.

Methods

A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 522 - 529
1 Apr 2009
Ryzewicz M Morgan SJ Linford E Thwing JI de Resende GVP Smith WR

Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central bone grafting and compared them to those of 20 who were treated with a traditional posterolateral graft. Central bone grafting entails a lateral approach, anterior to the fibula and interosseous membrane which is used to create a central space filled with cancellous iliac crest autograft. Upon consolidation, a tibiofibular synostosis is formed that is strong enough for weight-bearing. This procedure has advantages over other methods of treatment for selected nonunions. Of the 24 patients with central bone grafting, 23 went on to radiographic and clinical union without further intervention. All healed within a mean of 20 weeks (10 to 48). No further bone grafts were required, and few complications were encountered. These results were comparable to those of the 20 patients who underwent posterolateral bone grafting who united at a mean of 31.3 weeks (16 to 60) but one of whom required below-knee amputation for intractable sepsis. Central bone grafting is a safe and effective treatment for difficult nonunions of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 867 - 871
1 Aug 2000
Ring D Jupiter JB Quintero J Sanders RA Marti RK

We treated 15 patients with atrophic nonunion of a diaphyseal fracture of the humerus with an associated bony defect using an autogenous cancellous bone graft and a plate to bridge the defect. There were nine men and six women with a mean age of 48 years. The mean length of the bony defect was 3 cm. At a mean follow-up of 30 months only one fracture failed to unite. This suggests that, in the presence of a well-vascularised envelope of muscle, the application of an autogenous cancellous bone graft in conjunction with a bridging plate represents a good alternative to more demanding surgical techniques


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1487 - 1494
1 Nov 2008
Zlowodzki M Brink O Switzer J Wingerter S Woodall J Petrisor BA Kregor PJ Bruinsma DR Bhandari M

We have studied the effect of shortening of the femoral neck and varus collapse on the functional capacity and quality of life of patients who had undergone fixation of an isolated intracapsular fracture of the hip with cancellous screws. After screening 660 patients at four university medical centres, 70 patients with a mean age of 71 years (20 to 90) met the inclusion criteria. Overall, 66% (46 of 70) of the fractures healed with > 5 mm of shortening and 39% (27 of 70) with > 5° of varus. Patients with severe shortening of the femoral neck had significantly lower short form-36 questionnaire (SF-36) physical functioning scores (no/mild (< 5 mm) vs severe shortening (> 10 mm); 74 vs 42 points, p < 0.001). A similar effect was noted with moderate shortening, suggesting a gradient effect (no/mild (< 5 mm) vs moderate shortening (5 to 10 mm); 74 vs 53 points, p = 0.011). Varus collapse correlated moderately with the occurrence of shortening (r = 0.66, p < 0.001). Shortening also resulted in a significantly lower EuroQol questionnaire (EQ5D) index scores (p = 0.05). In a regression analysis shortening of the femoral neck was the only significant variable predictive of a low SF-36 physical functioning score (p < 0.001)


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


Aims

Monocyte-lymphocyte ratio (MLR) or neutrophil-lymphocyte ratio (NLR) are useful for diagnosing periprosthetic joint infection (PJI), but their diagnostic values are unclear for screening fixation-related infection (FRI) in patients for whom conversion total hip arthroplasty (THA) is planned after failed internal fixation for femoral neck fracture.

Methods

We retrospectively included 340 patients who underwent conversion THA after internal fixation for femoral neck fracture from January 2008 to September 2020. Those patients constituted two groups: noninfected patients and patients diagnosed with FRI according to the 2013 International Consensus Meeting Criteria. Receiver operating characteristic (ROC) curves were used to determine maximum sensitivity and specificity of these two preoperative ratios. The diagnostic performance of the two ratios combined with preoperative CRP or ESR was also evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 301 - 303
1 Mar 1997
Boyer MI Axelrod TS

We describe a new surgical treatment of atrophic nonunion of the clavicle. The nonunion is excised by cuts at 45° to the long axis and repair uses 3.5 mm pelvic reconstruction or dynamic compression plates, with a lag screw to provide interfragmentary compression. The site is grafted with cancellous bone. We have been successful in all seven patients, with early return to normal function. The consequent narrowing of the shoulder girdle is fully acceptable for appearance and function


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 253 - 257
1 Mar 1996
Sugano N Masuhara K Nakamura N Ochi T Hirooka A Hayami Y

We have carried out a prospective study of 17 patients (14 women, 3 men) of mean age 48 years (21 to 76) with transcervical fractures of the femur using MRI to detect early evidence of avascular necrosis of the head. Two fractures were Garden stage I, 12 stage II, and three stage III. We performed internal fixation under radiological control at a mean of five days (2 to 15) after injury using a titanium cannulated cancellous screw or a titanium compression hip screw. MRI was performed at one, six and 12 months and then yearly after operation. T1- and T2-weighted images were obtained by a spin-echo technique. The duration of follow-up of patients who did not subsequently require replacement of the head of the femur was from 2 to 5 years (mean 3.2). One month after operation eight of the 17 hips showed a band of low signal intensity on T1-weighted images and high signal intensity on T2-weighted images indicating lesions in the femoral head away from the fracture line. These were of three types: type I was a small infarct at the superolateral region of the femoral head and was seen in three hips; type II was a shallow lesion from the superolateral region to the fovea of the femoral head (three hips); and type III was a large lesion occupying most of the femoral head (two hips). No further changes were seen in the MRI after six months from operation. Collapse of the femoral head did not occur in the three hips with type-I lesions, but two of the three type-II hips and both type-III hips subsequently collapsed. At the final follow-up the three hips with a type-I lesion and one with a type-II were still asymptomatic but radiography showed sclerosis in the femoral head corresponding to the MRI lesions. The nine hips which showed no changes on MRI at one month had no abnormal findings on physical examination, radiography or MRI at final follow-up


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 361 - 369
1 Mar 2018
Sprague S Bhandari M Heetveld MJ Liew S Scott T Bzovsky S Heels-Ansdell D Zhou Q Swiontkowski M Schemitsch EH

Aims

The primary aim of this prognostic study was to identify baseline factors associated with physical health-related quality of life (HRQL) in patients after a femoral neck fracture. The secondary aims were to identify baseline factors associated with mental HRQL, hip function, and health utility.

Patients and Methods

Patients who were enrolled in the Fixation using Alternative Implants for the Treatment of Hip Fractures (FAITH) trial completed the 12-item Short Form Health Survey (SF-12), Western Ontario and McMaster Universities Arthritis Index, and EuroQol 5-Dimension at regular intervals for 24 months. We conducted multilevel mixed models to identify factors potentially associated with HRQL.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1002 - 1008
1 Aug 2019
Al-Hourani K Stoddart M Khan U Riddick A Kelly M

Aims

Type IIIB open tibial fractures are devastating high-energy injuries. At initial debridement, the surgeon will often be faced with large bone fragments with tenuous, if any, soft-tissue attachments. Conventionally these are discarded to avoid infection. We aimed to determine if orthoplastic reconstruction using mechanically relevant devitalized bone (ORDB) was associated with an increased infection rate in type IIIB open tibial shaft fractures.

Patient and Methods

This was a consecutive cohort study of 113 patients, who had sustained type IIIB fractures of the tibia following blunt trauma, over a four-year period in a level 1 trauma centre. The median age was 44.3 years (interquartile range (IQR) 28.1 to 65.9) with a median follow-up of 1.7 years (IQR 1.2 to 2.1). There were 73 male patients and 40 female patients. The primary outcome measures were deep infection rate and number of operations. The secondary outcomes were nonunion and flap failure.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 162 - 169
1 Feb 2019
Catagni MA Azzam W Guerreschi F Lovisetti L Poli P Khan MS Di Giacomo LM

Aims

Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental tibial bone defects. However, the difference in the incidence of additional procedures, the true complications, and the final results have not been investigated.

Patients and Methods

A total of 86 consecutive patients with a long tibial bone defect (≥ 8 cm), who were treated between January 2008 and January 2015, were retrospectively reviewed. A total of 45 were treated by BFT and 41 by TFT. The median age of the 45 patients in the BFT group was 43 years (interquartile range (IQR) 23 to 54).


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 478 - 483
1 Apr 2019
Borg T Hernefalk B Hailer NP

Aims

Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and internal fixation (ORIF), or with acute total hip arthroplasty (THA). A combination of ORIF and acute THA, an approach called ’combined hip procedure’ (CHP), has been advocated and our aim was to compare the outcome after CHP or ORIF alone.

Patients and Methods

A total of 27 patients with similar acetabular fractures (severe acetabular impaction with or without concomitant femoral head injury) with a mean age of 72.2 years (50 to 89) were prospectively followed for a minimum of two years. In all, 14 were treated with ORIF alone and 13 were treated with a CHP. Hip joint and patient survival were estimated. Operating times, blood loss, radiological outcomes, and patient-reported outcomes were assessed.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims

The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria.

Patients and Methods

Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


Bone & Joint Research
Vol. 6, Issue 7 | Pages 423 - 432
1 Jul 2017
van der Stok J Hartholt KA Schoenmakers DAL Arts JJC

Objectives

The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery.

Methods

A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.


Aims

The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment.

Patients and Methods

Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 233 - 241
1 Feb 2018
Ohmori T Kitamura T Nishida T Matsumoto T Tokioka T

Aim

There is not adequate evidence to establish whether external fixation (EF) of pelvic fractures leads to a reduced mortality. We used the Japan Trauma Data Bank database to identify isolated unstable pelvic ring fractures to exclude the possibility of blood loss from other injuries, and analyzed the effectiveness of EF on mortality in this group of patients.

Patients and Methods

This was a registry-based comparison of 1163 patients who had been treated for an isolated unstable pelvic ring fracture with (386 patients) or without (777 patients) EF. An isolated pelvic ring fracture was defined by an Abbreviated Injury Score (AIS) for other injuries of < 3. An unstable pelvic ring fracture was defined as having an AIS ≥ 4. The primary outcome of this study was mortality. A subgroup analysis was carried out for patients who required blood transfusion within 24 hours of arrival in the Emergency Department and those who had massive blood loss (AIS code: 852610.5). Propensity-score matching was used to identify a cohort like the EF and non-EF groups.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 680 - 685
1 May 2017
Morris R Hossain M Evans A Pallister I

Aims

This study describes the use of the Masquelet technique to treat segmental tibial bone loss in 12 patients.

Patients and Methods

This retrospective case series reviewed 12 patients treated between 2010 and 2015 to determine their clinical outcome. Patients were mostly male with a mean age of 36 years (16 to 62). The outcomes recorded included union, infection and amputation. The mean follow-up was 675 days (403 to 952).


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives

The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator.

Materials and Methods

An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 128 - 133
1 Jan 2017
Socci AR Casemyr NE Leslie MP Baumgaertner MR

Aims

The aim of this paper is to review the evidence relating to the anatomy of the proximal femur, the geometry of the fracture and the characteristics of implants and methods of fixation of intertrochanteric fractures of the hip.

Materials and Methods

Relevant papers were identified from appropriate clinical databases and a narrative review was undertaken.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 50 - 59
1 Jan 2017
Carli AV Negus JJ Haddad FS

Aims

Periprosthetic femoral fractures (PFF) following total hip arthroplasty (THA) are devastating complications that are associated with functional limitations and increased overall mortality. Although cementless implants have been associated with an increased risk of PFF, the precise contribution of implant geometry and design on the risk of both intra-operative and post-operative PFF remains poorly investigated. A systematic review was performed to aggregate all of the PFF literature with specific attention to the femoral implant used.

Patients and Methods

A systematic search strategy of several journal databases and recent proceedings from the American Academy of Orthopaedic Surgeons was performed. Clinical articles were included for analysis if sufficient implant description was provided. All articles were reviewed by two reviewers. A review of fundamental investigations of implant load-to-failure was performed, with the intent of identifying similar conclusions from the clinical and fundamental literature.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1399 - 1405
1 Oct 2016
Rohilla R Wadhwani J Devgan A Singh R Khanna M

Aims

This is a prospective randomised study which compares the radiological and functional outcomes of ring and rail fixators in patients with an infected gap (> 3 cm) nonunion of the tibia.

Patients and Methods

Between May 2008 and February 2013, 70 patients were treated at our Institute for a posttraumatic osseocutaneous defect of the tibia measuring at least 3 cm. These were randomised into two groups of 35 patients using the lottery method. Group I patients were treated with a ring fixator and group II patients with a rail fixator. The mean age was 33.2 years (18 to 64) in group I and 29.3 years (18 to 65) in group II. The mean bone gap was 5.84 cm in group I and 5.78 cm in group II.

The mean followup was 33.8 months in group I and 32.6 months in group II. Bone and functional results were assessed using the classification of the Association for the Study and Application of the Method of Ilizarov (ASAMI). Functional results were also assessed at six months using the short musculoskeletal functional assessment (SMFA) score.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1126 - 1131
1 Aug 2016
Shiels SM Cobb RR Bedigrew KM Ritter G Kirk JF Kimbler A Finger Baker I Wenke JC

Aims

Demineralised bone matrix (DBM) is rarely used for the local delivery of prophylactic antibiotics. Our aim, in this study, was to show that a graft with a bioactive glass and DBM combination, which is currently available for clinical use, can be loaded with tobramycin and release levels of antibiotic greater than the minimum inhibitory concentration for Staphylococcus aureus without interfering with the bone healing properties of the graft, thus protecting the graft and surrounding tissues from infection.

Materials and Methods

Antibiotic was loaded into a graft and subsequently evaluated for drug elution kinetics and the inhibition of bacterial growth. A rat femoral condylar plug model was used to determine the effect of the graft, loaded with antibiotic, on bone healing.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 1003 - 1008
1 Jul 2016
Fenton P Al-Nammari S Blundell C Davies M

Aims

Although infrequent, a fracture of the cuboid can lead to significant disruption of the integrity of the midfoot and its function. The purpose of this study was to classify the pattern of fractures of the cuboid, relate them to the mechanism of injury and suggest methods of managing them.

Patients and Methods

We performed a retrospective review of patients with radiologically reported cuboid fractures. Fractures were grouped according to commonly occurring patterns of injury. A total of 192 fractures in 188 patients were included. They were classified into five patterns of injury.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 686 - 689
1 May 2016
Griffin XL Parsons N McArthur J Achten J Costa ML

Aims

The aim of this study was to inform a definitive trial which could determine the clinical effectiveness of the X-Bolt Dynamic Hip Plating System compared with the sliding hip screw for patients with complex pertrochanteric fragility fractures of the femur.

Patients and Methods

This was a single centre, participant blinded, randomised, standard-of-care controlled pilot trial. Patients aged 60 years and over with AO/ASIF A2 and A3 type femoral pertrochanteric fractures were eligible.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1402 - 1405
1 Oct 2013
Parker M Cawley S Palial V

A consecutive series of 320 patients with an intracapsular fracture of the hip treated with a dynamic locking plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients were followed for a minimum of two years. During the follow-up period 109 patients died.

There were 112 undisplaced fractures, of which three (2.7%) developed nonunion or re-displacement and five (4.5%) developed avascular necrosis of the femoral head. Revision to an arthroplasty was required for five patients (4.5%). A further six patients (5.4%) had elective removal of the plate and screws.

There were 208 displaced fractures, of which 32 (15.4%) developed nonunion or re-displacement and 23 (11.1%) developed avascular necrosis. A further four patients (1.9%) developed a secondary fracture around the TFN. Revision to a hip replacement was required for 43 patients (20.7%) patients and a further seven (3.3%) had elective removal of the plate and screws.

It is suggested that the stronger distal fixation combined with rotational stability may lead to a reduced incidence of complications related to the healing of the fracture when compared with other contemporary fixation devices but this needs to be confirmed in further studies.

Cite this article: Bone Joint J 2013;95-B:1402–5.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 696 - 704
1 May 2015
Kenawey M Krettek C Addosooki A Salama W Liodakis E

Unstable pelvic injuries in young children with an immature pelvis have different modes of failure from those in adolescents and adults. We describe the pathoanatomy of unstable pelvic injuries in these children, and the incidence of associated avulsion of the iliac apophysis and fracture of the ipsilateral fifth lumbar transverse process (L5-TP). We retrospectively reviewed the medical records of 33 children with Tile types B and C pelvic injuries admitted between 2007 and 2014; their mean age was 12.6 years (2 to 18) and 12 had an immature pelvis. Those with an immature pelvis commonly sustained symphyseal injuries anteriorly with diastasis, rather than the fractures of the pubic rami seen in adolescents. Posteriorly, transsacral fractures were more commonly encountered in mature children, whereas sacroiliac dislocations and fracture-dislocations were seen in both age groups. Avulsion of the iliac apophysis was identified in eight children, all of whom had an immature pelvis with an intact ipsilateral L5-TP. Young children with an immature pelvis are more susceptible to pubic symphysis and sacroiliac diastasis, whereas bony failures are more common in adolescents. Unstable pelvic injuries in young children are commonly associated with avulsion of the iliac apophysis, particularly with displaced SI joint dislocation and an intact ipsilateral L5-TP.

Cite this article: Bone Joint J 2015; 97-B:696–704.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1165 - 1171
1 Sep 2013
Arastu MH Kokke MC Duffy PJ Korley REC Buckley RE

Coronal plane fractures of the posterior femoral condyle, also known as Hoffa fractures, are rare. Lateral fractures are three times more common than medial fractures, although the reason for this is not clear. The exact mechanism of injury is likely to be a vertical shear force on the posterior femoral condyle with varying degrees of knee flexion. These fractures are commonly associated with high-energy trauma and are a diagnostic and surgical challenge. Hoffa fractures are often associated with inter- or supracondylar distal femoral fractures and CT scans are useful in delineating the coronal shear component, which can easily be missed. There are few recommendations in the literature regarding the surgical approach and methods of fixation that may be used for this injury. Non-operative treatment has been associated with poor outcomes. The goals of treatment are anatomical reduction of the articular surface with rigid, stable fixation to allow early mobilisation in order to restore function. A surgical approach that allows access to the posterior aspect of the femoral condyle is described and the use of postero-anterior lag screws with or without an additional buttress plate for fixation of these difficult fractures.

Cite this article: Bone Joint J 2013;95-B:1165–71.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 106 - 115
1 Apr 2016
Gruber HE Ode G Hoelscher G Ingram J Bethea S Bosse MJ

Objectives

The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics.

Methods

Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired student t-test (two tailed; p < 0.05 was considered significant).


We evaluated the outcome of treatment of nonunion of an intracapsular fracture of the femoral neck in young patients using two cannulated screws and a vascularised bone graft. A total of 32 patients (15 women and 17 men, with a mean age of 36.5 years; 20 to 50) with failed internal fixation of an intracapsular fracture were included in the study. Following removal of the primary fixation, two cannulated compression screws were inserted with a vascularised iliac crest bone graft based on the ascending branch of the lateral femoral circumflex artery.

At a mean follow-up of 6.8 years (4 to 10), union was achieved in 27 hips (84%). A total of five patients with a mean age of 40.5 years (35 to 50) had a persistent nonunion and underwent total hip arthroplasty as also did two patients whose fracture united but who developed osteonecrosis of the femoral head two years post-operatively. Statistical analysis showed that younger patients achieved earlier and more reliable union (p < 0.001). The functional outcome, as assessed by the Harris Hip score, was better in patients aged < 45 years compared with those aged > 45 years (p < 0.001).

These findings suggest that further fixation using two cannulated compression screws and a vascularised iliac crest bone graft is an effective salvage treatment in patients aged <  45 years, in whom osteosynthesis of a displaced intracapsular fractures of the femoral neck has failed.

Cite this article: Bone Joint J 2015; 97-B:988–91.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 583 - 597
1 May 2013
Kurien T Pearson RG Scammell BE

We reviewed 59 bone graft substitutes marketed by 17 companies currently available for implantation in the United Kingdom, with the aim of assessing the peer-reviewed literature to facilitate informed decision-making regarding their use in clinical practice. After critical analysis of the literature, only 22 products (37%) had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita), Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question the need for so many different products, especially with limited published clinical evidence for their efficacy, and conclude that there is a considerable need for further prospective randomised trials to facilitate informed decision-making with regard to the use of current and future bone graft substitutes in clinical practice.

Cite this article: Bone Joint J 2013;95-B:583–97.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1143 - 1154
1 Sep 2014
Mauffrey C Cuellar III DO Pieracci F Hak DJ Hammerberg EM Stahel PF Burlew CC Moore EE

Exsanguination is the second most common cause of death in patients who suffer severe trauma. The management of haemodynamically unstable high-energy pelvic injuries remains controversial, as there are no universally accepted guidelines to direct surgeons on the ideal use of pelvic packing or early angio-embolisation. Additionally, the optimal resuscitation strategy, which prevents or halts the progression of the trauma-induced coagulopathy, remains unknown. Although early and aggressive use of blood products in these patients appears to improve survival, over-enthusiastic resuscitative measures may not be the safest strategy.

This paper provides an overview of the classification of pelvic injuries and the current evidence on best-practice management of high-energy pelvic fractures, including resuscitation, transfusion of blood components, monitoring of coagulopathy, and procedural interventions including pre-peritoneal pelvic packing, external fixation and angiographic embolisation.

Cite this article: Bone Joint J 2014; 96-B:1143–54.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months.

The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery.

The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used.

The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less.

Cite this article: Bone Joint J 2015; 97-B:836–41


Bone & Joint 360
Vol. 2, Issue 1 | Pages 42 - 43
1 Feb 2013
Moran CG


Bone & Joint Research
Vol. 1, Issue 4 | Pages 50 - 55
1 Apr 2012
O’Neill F Condon F McGloughlin T Lenehan B Coffey C Walsh M

Introduction

The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the synthetic material could produce results similar to those of the osteoporotic bone, it could reduce or eliminate the need for testing of implants on bone.

Methods

Pushout studies were performed with the dynamic hip screw (DHS) and the DHS Blade in both cadaveric femoral heads and artificial bone substitutes in the form of polyurethane foam blocks of different density. The pushout studies were performed as a means of comparing the force displacement curves produced by each implant within each material.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1482 - 1487
1 Nov 2007
Gupta A

We describe a series of 20 patients with ununited fractures of the femoral neck following neglected trauma or failed primary internal fixation who were seen at a mean of 7.5 months (2 to 18) following injury. Open reduction and internal fixation of the fracture was performed in all patients, together with a myoperiosteal flap on the quadratus femoris muscle pedicle.

Union occurred at a mean of 4.9 months (2 to 10) in all patients. The mean follow-up was for 70 months (14 to 144). There was no further progression in six of seven patients with pre-operative radiological evidence of osteonecrosis of the femoral head. One patient had delayed collapse and flattening of the femoral head ten years after union of the fracture, but remained asymptomatic.

This study demonstrates the orthopaedic application of myoperiosteal grafting for inducing osteogenesis in a difficult clinical situation.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1252 - 1257
1 Sep 2014
Habib M Tanwar YS Jaiswal A Singh SP Sinha S lal H

In order to achieve satisfactory reduction of complex distal humeral fractures, adequate exposure of the fracture fragments and the joint surface is required. Several surgical exposures have been described for distal humeral fractures. We report our experience using the anconeus pedicle olecranon flip osteotomy approach. This involves detachment of the triceps along with a sliver of olecranon, which retains the anconeus pedicle. We report the use of this approach in ten patients (six male, four female) with a mean age of 38.4 years (28 to 51). The mean follow-up was 15 months (12 to 18) with no loss to follow-up. Elbow function was graded using the Mayo Score. The results were excellent in four patients, good in five and fair in one patient. The mean time to both fracture and osteotomy union was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We found this approach gave reliably good exposure for these difficult fractures enabling anatomical reduction and bicondylar plating without complications.

Cite this article: Bone Joint J 2014;96-B:1252–7.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 652 - 657
1 May 2014
Griffin XL Parsons N Achten J Costa ML

We compared a new fixation system, the Targon Femoral Neck (TFN) hip screw, with the current standard treatment of cannulated screw fixation. This was a single-centre, participant-blinded, randomised controlled trial. Patients aged 65 years and over with either a displaced or undisplaced intracapsular fracture of the hip were eligible. The primary outcome was the risk of revision surgery within one year of fixation.

A total of 174 participants were included in the trial. The absolute reduction in risk of revision was of 4.7% (95% CI 14.2 to 22.5) in favour of the TFN hip screw (chi-squared test, p = 0.741), which was less than the pre-specified level of minimum clinically important difference. There were no significant differences in any of the secondary outcome measures.

We found no evidence of a clinical difference in the risk of revision surgery between the TFN hip screw and cannulated screw fixation for patients with an intracapsular fracture of the hip.

Cite this article: Bone Joint J 2014;96-B:652–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°.

The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans.

Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 249 - 253
1 Feb 2014
Euler SA Hengg C Kolp D Wambacher M Kralinger F

Antegrade nailing of proximal humeral fractures using a straight nail can damage the bony insertion of the supraspinatus tendon and may lead to varus failure of the construct. In order to establish the ideal anatomical landmarks for insertion of the nail and their clinical relevance we analysed CT scans of bilateral proximal humeri in 200 patients (mean age 45.1 years (sd 19.6; 18 to 97) without humeral fractures. The entry point of the nail was defined by the point of intersection of the anteroposterior and lateral vertical axes with the cortex of the humeral head. The critical point was defined as the intersection of the sagittal axis with the medial limit of the insertion of the supraspinatus tendon on the greater tuberosity. The region of interest, i.e. the biggest entry hole that would not encroach on the insertion of the supraspinatus tendon, was calculated setting a 3 mm minimal distance from the critical point. This identified that 38.5% of the humeral heads were categorised as ‘critical types’, due to morphology in which the predicted offset of the entry point would encroach on the insertion of the supraspinatus tendon that may damage the tendon and reduce the stability of fixation.

We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk.

Cite this article: Bone Joint J 2014;96-B:249–53.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1218 - 1224
1 Sep 2007
Molloy AP Myerson MS Yoon P

We have treated 14 patients (15 fractures) with nonunion of an intra-articular fracture of the body of the calcaneum. The mean follow-up was six years (2 to 8.5). A total of 14 fractures (93%) had initially been treated operatively with 12 (86%) having non-anatomical reductions. Four feet (27%) had concomitant osteomyelitis. Of the nonunions, 14 (93%) went on to eventual union after an average of two reconstructive procedures. All underwent bone grafting of the nonunion. The eventual outcome was a subtalar arthrodesis in ten (67%) cases, a triple arthrodesis in four (27%) and a nonunion in one (6%). Three patients had a wound dehiscence; all required a local rotation flap. The mean American Orthopaedic Foot and Ankle Society score at latest follow-up was 69, and the mean Visual analogue scale was 3. Of those who were initially employed, 82% (9 of 11) eventually returned to work. We present an algorithm for the treatment of calcaneal nonunion, and conclude that despite a relatively high rate of complication, this complex surgery has a high union rate and a good functional outcome.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:206–9.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 983 - 987
1 Jul 2013
Soliman O Koptan W Zarad A

In Neer type II (Robinson type 3B) fractures of the distal clavicle the medial fragment is detached from the coracoclavicular ligaments and displaced upwards, whereas the lateral fragment, which is usually small, maintains its position. Several fixation techniques have been suggested to treat this fracture. The aim of this study was to assess the outcome of patients with type II distal clavicle fractures treated with coracoclavicular suture fixation using three loops of Ethibond. This prospective study included 14 patients with Neer type II fractures treated with open reduction and coracoclavicular fixation. Ethibond sutures were passed under the coracoid and around the clavicle (UCAC loop) without making any drill holes in the proximal or distal fragments. There were 11 men and three women with a mean age of 34.57 years (29 to 41). Patients were followed for a mean of 24.64 months (14 to 31) and evaluated radiologically and clinically using the Constant score. Fracture union was obtained in 13 patients at a mean of 18.23 weeks (13 to 23) and the mean Constant score was 96.07 (91 to 100). One patient developed an asymptomatic fibrous nonunion at one year. This study suggests that open reduction and internal fixation of unstable distal clavicle fractures using UCAC loops can provide rigid fixation and lead to bony union. This technique avoids using metal hardware, preserves the acromioclavicular joint and provides adequate stability with excellent results.

Cite this article: Bone Joint J 2013;95-B:983–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 367 - 373
1 Mar 2005
Heetveld MJ Raaymakers ELFB van Eck-Smit BL van Walsum ADP Luitse JSK

The results of meta-analysis show a revision rate of 33% for internal fixation of displaced fractures of the femoral neck, mostly because of nonunion. Osteopenia and osteoporosis are highly prevalent in elderly patients. Bone density has been shown to correlate with the intrinsic stability of the fixation of the fracture in cadaver and retrospective studies. We aimed to confirm or refute this finding in a clinical setting.

We performed a prospective, multicentre study of 111 active patients over 60 years of age with a displaced fracture of the femoral neck which was eligible for internal fixation. The bone density of the femoral neck was measured pre-operatively by dual-energy x-ray absorptiometry (DEXA). The patients were divided into two groups namely, those with osteopenia (66%, mean T-score −1.6) and those with osteoporosis (34%, mean T-score −3.0). Age (p = 0.47), gender (p = 0.67), delay to surgery (p = 0.07), the angle of the fracture (p = 0.33) and the type of implant (p = 0.48) were similar in both groups.

Revision to arthroplasty was performed in 41% of osteopenic and 42% of osteoporotic patients (p = 0.87). Morbidity (p = 0.60) and mortality were similar in both groups (p = 0.65). Our findings show that the clinical outcome of internal fixation for displaced fractures of the femoral neck does not depend on bone density and that pre-operative DEXA is not useful.