Advertisement for orthosearch.org.uk
Results 1 - 20 of 531
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 176 - 180
1 Jun 2020
Lee G Colen DL Levin LS Kovach SJ

Aims. The integrity of the soft tissue envelope is crucial for successful treatment of infected total knee arthroplasty (TKA). The purpose of this study was to evaluate the rate of limb salvage, infection control, and clinical function following microvascular free flap coverage for salvage of the infected TKA. Methods. We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and seven women with a mean age of 61.2 years (39 to 81). The median number of procedures performed prior to soft tissue coverage was five (2 to 9) and all patients had failed at least one two-stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function. Results. In all, one patient was lost to follow-up prior to 12 months. The remaining 22 patients were followed for a mean of 46 months (12 to 92). At latest follow-up, four patients (18%) had undergone amputation for failure of treatment and persistent infection. For the other 18 patients, 11 patients (50%) had maintained a knee prosthesis in place while seven patients had undergone resections for persistent infection but retained their limbs (32%). Reoperations were common following coverage and reimplantation. The median number of additional procedures was two (0 to 6). Clinical function was poor in patients who underwent reimplantation and retained a knee prosthesis following free flap coverage with a mean KSS score for pain and function of 44 (0 to 70) and 30 (0 to 65), respectively. All patients required an assistive device. Extensor mechanism problems and extensor lag requiring bracing were common following limb salvage and prosthesis reimplantation. Conclusion. Microvascular tissue transfer for management of infected TKA can be successful in limb salvage (82%) but clinical outcomes in salvaged limbs were poor. Cite this article: Bone Joint J 2020;102-B(6 Supple A):176–180


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 831 - 838
1 Jul 2018
Ibrahim MM Poitras S Bunting AC Sandoval E Beaulé PE

Aims. What represents clinically significant acetabular undercoverage in patients with symptomatic cam-type femoroacetabular impingement (FAI) remains controversial. The aim of this study was to examine the influence of the degree of acetabular coverage on the functional outcome of patients treated arthroscopically for cam-type FAI. Patients and Methods. Between October 2005 and June 2016, 88 patients (97 hips) underwent arthroscopic cam resection and concomitant labral debridement and/or refixation. There were 57 male and 31 female patients with a mean age of 31.0 years (17.0 to 48.5) and a mean body mass index (BMI) of 25.4 kg/m. 2. (18.9 to 34.9). We used the Hip2Norm, an object-oriented-platform program, to perform 3D analysis of hip joint morphology using 2D anteroposterior pelvic radiographs. The lateral centre-edge angle, anterior coverage, posterior coverage, total femoral coverage, and alpha angle were measured for each hip. The presence or absence of crossover sign, posterior wall sign, and the value of acetabular retroversion index were identified automatically by Hip2Norm. Patient-reported outcome scores were collected preoperatively and at final follow-up with the Hip Disability and Osteoarthritis Outcome Score (HOOS). Results. At a mean follow-up of 2.7 years (1 to 8, . sd. 1.6), all functional outcome scores significantly improved overall. Radiographically, only preoperative anterior coverage had a negative correlation with the improvement of the HOOS symptom subscale (r = -0.28, p = 0.005). No significant difference in relative change in HOOS subscale scores was found according to the presence or absence of radiographic signs of retroversion. Discussion. Our study demonstrated the anterior coverage as an important modifier influencing the functional outcome of arthroscopically treated cam-type FAI. Cite this article: Bone Joint J 2018;100-B:831–8


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 40 - 46
1 May 2024
Massè A Giachino M Audisio A Donis A Giai Via R Secco DC Limone B Turchetto L Aprato A

Aims. Ganz’s studies made it possible to address joint deformities on both the femoral and acetabular side brought about by Perthes’ disease. Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency, along with periacetabular osteotomy (PAO), which may enhance coverage and containment. The purpose of this study is to show the clinical and morphological outcomes of the technique and the use of an implemented planning approach. Methods. From September 2015 to December 2021, 13 FHROs were performed on 11 patients for Perthes’ disease in two centres. Of these, 11 hips had an associated PAO. A specific CT- and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiological parameters (sphericity index, extrusion index, integrity of the Shenton’s line, lateral centre-edge angle (LCEA), Tönnis angle), and clinical parameters (range of motion, visual analogue scale (VAS) for pain, Merle d'Aubigné-Postel score, modified Harris Hip Score (mHHS), and EuroQol five-dimension five-level health questionnaire (EQ-5D-5L)). Early and late complications were reported. Results. The mean follow-up was 39.7 months (standard deviation (SD) 26.4). The mean age at surgery was 11.4 years (SD 1.6). No major complications were recorded. One patient required a total hip arthroplasty. Mean femoral head sphericity increased from 46.8% (SD 9.34%) to 70.2% (SD 15.44; p < 0.001); mean LCEA from 19.2° (SD 9.03°) to 44° (SD 10.27°; p < 0.001); mean extrusion index from 37.8 (SD 8.70) to 7.5 (SD 9.28; p < 0.001); and mean Tönnis angle from 16.5° (SD 12.35°) to 4.8° (SD 4.05°; p = 0.100). The mean VAS improved from 3.55 (SD 3.05) to 1.22 (1.72; p = 0.06); mean Merle d’Aubigné-Postel score from 14.55 (SD 1.74) to 16 (SD 1.6; p = 0.01); and mean mHHS from 60.6 (SD 18.06) to 81 (SD 6.63; p = 0.021). The EQ-5D-5L also showed significant improvements. Conclusion. FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical, and morphological outcomes in Perthes’ disease. The newly introduced simulation and planning algorithm may help to further refine the technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):40–46


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 314 - 319
1 Mar 2013
Masjedi M Nightingale CL Azimi DY Cobb JP

We examined the relationship between the size of the femoral cam in femoroacetabular impingement (FAI) and acetabular pathomorphology to establish if pincer impingement exists in patients with a femoral cam. CT scans of 37 symptomatic impinging hips with a femoral cam were analysed in a three-dimensional study and were compared with 34 normal hips. The inclination and version of the acetabulum as well as the acetabular rim angle and the bony acetabular coverage were calculated. These measurements were correlated with the size and shape of the femoral cams. While the size of the femoral cam varied characteristically, the acetabular morphology of the two groups was similar in terms of version (normal mean 23° (. sd. 7°); cam mean 22° (. sd.  9°)), inclination (normal mean 57° (. sd. 5°); cam mean 56° (. sd. 5°)), acetabular coverage (normal mean 41% (. sd. 5%); cam mean 42% (. sd. 4%)) and the mean acetabular rim angle (normal mean 82° (. sd. 5°); cam mean 83° (. sd. 4°)). We found no correlation between acetabular morphology and the severity of cam lesion and no evidence of either global or focal over-coverage to support the diagnosis of ‘mixed’ FAI. The femoral cam may provoke edge loading but removal of any acetabular bearing surface when treating cam FAI might induce accelerated wear. Cite this article: Bone Joint J 2013;95-B:314–19


Bone & Joint Research
Vol. 2, Issue 1 | Pages 1 - 8
1 Jan 2013
Costa AJ Lustig S Scholes CJ Balestro J Fatima M Parker DA

Objectives. There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design. Methods. A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated. Results. Excellent intra- and interobserver reliability was observed for total coverage, when minimal component overhang (intraclass correlation coefficient (ICC) = 0.87) or no component overhang (ICC = 0.92) was permitted, regardless of rotational restrictions. Conclusions. Measurement of tibial coverage can be reliable using the templating method described even if the rotational axis selected still has a minor influence


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1327 - 1332
1 Dec 2023
Morris WZ Kak A Mayfield LM Kang MS Jo C Kim HKW

Aims

Abduction bracing is commonly used to treat developmental dysplasia of the hip (DDH) following closed reduction and spica casting, with little evidence to support or refute this practice. The purpose of this study was to determine the efficacy of abduction bracing after closed reduction in improving acetabular index (AI) and reducing secondary surgery for residual hip dysplasia.

Methods

We performed a retrospective review of patients treated with closed reduction for DDH at a single tertiary referral centre. Demographic data were obtained including severity of dislocation based on the International Hip Dysplasia Institute (IHDI) classification, age at reduction, and casting duration. Patients were prescribed no abduction bracing, part-time, or full-time wear post-reduction and casting. AI measurements were obtained immediately upon cast removal and from two- and four-year follow-up radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 144 - 150
1 Jan 1998
Hunziker EB Kapfinger E Müller ME

Lesions within the articular cartilage layer of synovial joints do not heal spontaneously. Some repair cells may appear, but their failure to become established may be related to problems of adhesion to proteoglycan-rich surfaces. We therefore investigated whether controlled enzymatic degradation of surface proteoglycan molecules to a depth of about 1 μm, using chondroitinase ABC, would improve coverage by repair cells. We created superficial lesions (1.0 × 0.2 × 5 mm) in the articular cartilage of mature rabbit knees and treated the surfaces with 1 U/ml of chondroitinase ABC for four minutes. The defects were studied by histomorphometry and electron microscopy at one, three and six months. At one month, untreated lesions were covered to a mean extent of 28% by repair cells; this was enhanced to a mean of 53% after enzyme treatment. By three months, the mean coverage of both control and chondroitinase-ABC-treated defects had diminished dramatically to 0.2% and 13%, respectively, but at six months both untreated and treated lesions had a similar coverage of about 30%, not significantly different from that achieved in untreated knees at one month. These findings suggest that, with time, chondrocytes near the surface of the defect may compensate for the loss of proteoglycans produced by enzyme treatment, thereby restoring the inhibitory properties of the matrix as regards cell adhesion. This supposition was confirmed by electron microscopy. Our results have an important bearing on attempts made to induce healing responses by transplanting chondrogenic cells or by applying growth factors


Bone & Joint Open
Vol. 3, Issue 1 | Pages 12 - 19
3 Jan 2022
Salih S Grammatopoulos G Burns S Hall-Craggs M Witt J

Aims

The lateral centre-edge angle (LCEA) is a plain radiological measure of superolateral cover of the femoral head. This study aims to establish the correlation between 2D radiological and 3D CT measurements of acetabular morphology, and to describe the relationship between LCEA and femoral head cover (FHC).

Methods

This retrospective study included 353 periacetabular osteotomies (PAOs) performed between January 2014 and December 2017. Overall, 97 hips in 75 patients had 3D analysis by Clinical Graphics, giving measurements for LCEA, acetabular index (AI), and FHC. Roentgenographical LCEA, AI, posterior wall index (PWI), and anterior wall index (AWI) were measured from supine AP pelvis radiographs. The correlation between CT and roentgenographical measurements was calculated. Sequential multiple linear regression was performed to determine the relationship between roentgenographical measurements and CT FHC.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 861 - 867
1 Aug 2004
Gopal S Giannoudis PV Murray A Matthews SJ Smith RM

We studied the outcome and functional status of 33 patients with 34 severe open tibial fractures (Gustilo grade IIIb and IIIc). The treatment regime consisted of radical debridement, immediate bony stabilisation and early soft-tissue cover using a muscle flap (free or rotational). The review included standardised assessments of health-related quality of life (SF-36 and Euroqol) and measurement of the following parameters: gait, the use of walking aids, limb-length discrepancy, knee and ankle joint function, muscle wasting and the cosmetic appearance of the limb. Personal comments and overall patient satisfaction were also recorded. The mean follow-up was 46 months (15 to 80).

There were 30 Gustilo grade IIIb fractures and and four grade IIIc fractures. Of the 33 patients, 29 had primary internal fixation and four, external fixation; 11 (34%) later required further surgery to achieve union and two needed bone transport procedures to reconstruct large segmental defects. The mean time to union was 41 weeks (12 to 104). Two patients (6.1%) developed deep infection; both resolved with treatment.

The mean SF-36 physical and mental scores were 49 and 62 respectively. The mean state of health score for the Euroqol was 68. Patients with isolated tibial fractures had a better outcome than those with other associated injuries on both scoring systems. Knee stiffness was noted in seven patients (21%) and ankle stiffness in 19 (56%); 12 patients (41%) returned to work. Our results compare favourably with previous outcome measurements published for both limb salvage and amputation. All patients were pleased to have retained their limbs.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1399 - 1407
1 Dec 2024
Fujii M Tanaka S Kawano S Ueno M Nagamine S Mawatari M

Aims. This study aimed to determine clinical outcomes; relationships between postoperative anterior, lateral, and posterior acetabular coverage and joint survival; and prognostic factors for joint survival after transposition osteotomy of the acetabulum (TOA). Methods. Data from 616 patients (800 hips) with hip dysplasia who underwent TOA between November 1998 and December 2019 were reviewed. The median follow-up period was 8.9 years (IQR 5 to 14). A medical notes review was conducted to collect demographic data, complications, and modified Harris Hip Score (mHHS). Radiological indicators of acetabular coverage included lateral centre-edge angle (LCEA), anterior wall index (AWI), and posterior wall index (PWI). The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors for failure. Results. Median mHHS improved from 68 preoperatively to 96 at the latest follow-up (p < 0.001). The overall joint survival rate was 97% at ten years and 70% at 20 years. For the postoperative LCEA subgroups, survival in the deficient group was lower than that in the excessive (p = 0.006) and normal (p = 0.007) groups. For the postoperative AWI subgroups, survival in the deficient group was lower than that in the excessive (p = 0.015) and normal (p < 0.001) groups. Multivariate analysis identified age (p = 0.010), Tönnis grade 2 (p < 0.001), roundness index (p = 0.003), fair joint congruity (p = 0.004), and postoperative AWI (p = 0.002) as independent risk factors. Conclusion. Deficient postoperative AWI adversely affected joint survival after TOA, underscoring the importance of sufficient anterior acetabular coverage, along with precise surgical indications, to ensure successful hip joint preservation in the treatment of hip dysplasia. Cite this article: Bone Joint J 2024;106-B(12):1399–1407


Bone & Joint Open
Vol. 3, Issue 12 | Pages 941 - 952
23 Dec 2022
Shah A Judge A Griffin XL

Aims. Several studies have reported that patients presenting during the evening or weekend have poorer quality healthcare. Our objective was to examine how timely surgery for patients with severe open tibial fracture varies by day and time of presentation and by type of hospital. This cohort study included patients with severe open tibial fractures from the Trauma Audit and Research Network (TARN). Methods. Provision of prompt surgery (debridement within 12 hours and soft-tissue coverage in 72 hours) was examined, using multivariate logistic regression to derive adjusted risk ratios (RRs). Time was categorized into three eight-hour intervals for each day of the week. The models were adjusted for treatment in a major trauma centre (MTC), sex, age, year of presentation, injury severity score, injury mechanism, and number of operations each patient received. Results. We studied 8,258 patients from 175 hospitals. Patients presenting during the day (08:00 to 15:59; risk ratio (RR) 1.11, 95% confidence interval (CI) 1.02 to 1.20) were more likely to receive debridement within 12 hours, and patients presenting at night (16:00 to 23:59; RR 0.56, 95% CI 0.51 to 0.62) were less likely to achieve the target; triage to a MTC had no effect. Day of presentation was associated with soft-tissue coverage within 72 hours; patients presenting on a Thursday or Friday being less likely to receive this surgery within 72 hours (Thursday RR 0.88, 95% CI 0.81 to 0.97; Friday RR 0.89, 95% CI 0.81 to 0.98), and the standard less likely to be achieved for those treated in ‘non-MTC’ hospitals (RR 0.76, 95% CI 0.70 to 0.82). Conclusion. Variations in care were observed for timely surgery for severe open tibial fractures with debridement surgery affected by time of presentation and soft-tissue coverage affected by day of presentation and type of hospital. The variation is unwarranted and highlights that there are opportunities to substantially improve the delivery and quality of care for patients with severe open tibial fracture. Cite this article: Bone Jt Open 2022;3(12):941–952


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four arthroplasty systems kept the stability ratio of standard liners constant (within 5%) across different sizes, while one system showed slight inconsistencies (within 10%), and ten arthroplasty systems showed large inconsistencies (range 11% to 28%). The stability ratio of constrained liners was consistent across different sizes in two arthroplasty systems and inconsistent in seven systems (range 18% to 106%). Conclusion. Large differences in jump height and resulting degree of constraint of rTSA liners were observed between different implant systems, and in many cases even within the same implant systems. While the immediate clinical effect remains unclear, in theory the degree of constraint of the liner plays an important role for the dislocation and notching risk of a rTSA system. Cite this article: Bone Jt Open 2024;5(10):818–824


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1656 - 1661
1 Nov 2021
Iwasa M Ando W Uemura K Hamada H Takao M Sugano N

Aims. Pelvic incidence (PI) is considered an important anatomical parameter for determining the sagittal balance of the spine. The contribution of an abnormal PI to hip osteoarthritis (OA) remains controversial. In this study, we aimed to investigate the relationship between PI and hip OA, and the difference in PI between hip OA without anatomical abnormalities (primary OA) and hip OA with developmental dysplasia of the hip (DDH-OA). Methods. In this study, 100 patients each of primary OA, DDH-OA, and control subjects with no history of hip disease were included. CT images were used to measure PI, sagittal femoral head coverage, α angle, and acetabular anteversion. PI was also subdivided into three categories: high PI (larger than 64.0°), medium PI (42.0° to 64.0°), and low PI (less than 42.0°). The anterior centre edge angles, posterior centre edge angles, and total sagittal femoral head coverage were measured. The correlations between PI and sagittal femoral head coverage, α angle, and acetabular anteversion were examined. Results. No significant difference in PI was observed between the three groups. There was no significant difference between the groups in terms of the category distribution of PI. The DDH-OA group had lower mean sagittal femoral head coverage than the other groups. There were no significant correlations between PI and other anatomical factors, including sagittal femoral head coverage, α angle, and acetabular anteversion. Conclusion. No associations were found between mean PI values or PI categories and hip OA. Furthermore, there was no difference in PI between patients with primary OA and DDH-OA. From our evaluation, we found no evidence of PI being an independent factor associated with the development of hip OA. Cite this article: Bone Joint J 2021;103-B(11):1656–1661


Bone & Joint 360
Vol. 12, Issue 1 | Pages 42 - 45
1 Feb 2023

The February 2023 Children’s orthopaedics Roundup. 360. looks at: Trends in management of paediatric distal radius buckle fractures; Pelvic osteotomy in patients with previous sacral-alar-iliac fixation; Sacral-alar-iliac fixation in patients with previous pelvic osteotomy; Idiopathic toe walking: an update on natural history, diagnosis, and treatment; A prediction model for treatment decisions in distal radial physeal injuries: a multicentre retrospective study; Angular deformities after percutaneous epiphysiodesis for leg length discrepancy; MRI assessment of anterior coverage is predictive of future radiological coverage; Predictive scoring for recurrent patellar instability after a first-time patellar dislocation


Bone & Joint 360
Vol. 12, Issue 2 | Pages 36 - 39
1 Apr 2023

The April 2023 Oncology Roundup. 360. looks at: Complete tumour necrosis after neoadjuvant chemotherapy defines good responders in patients with Ewing’s sarcoma; Monitoring vascularized fibular autograft: are radiographs enough?; Examining patient perspectives on sarcoma surveillance; The management of sacral tumours; Venous thromboembolism and major bleeding in the clinical course of osteosarcoma and Ewing’s sarcoma; Secondary malignancies after Ewing’s sarcoma: what is the disease burden?; Outcomes of distal radial endoprostheses for tumour reconstruction: a single centre experience over 15 years; Is anaerobic coverage during soft-tissue sarcoma resection needed?; Is anaerobic coverage during soft-tissue sarcoma resection needed?


Bone & Joint Open
Vol. 4, Issue 10 | Pages 742 - 749
6 Oct 2023
Mabrouk A Abouharb A Stewart G Palan J Pandit H

Aims. Prophylactic antibiotic regimens for elective primary total hip and knee arthroplasty vary widely across hospitals and trusts in the UK. This study aimed to identify antibiotic prophylaxis regimens currently in use for elective primary arthroplasty across the UK, establish variations in antibiotic prophylaxis regimens and their impact on the risk of periprosthetic joint infection (PJI) in the first-year post-index procedure, and evaluate adherence to current international consensus guidance. Methods. The guidelines for the primary and alternative recommended prophylactic antibiotic regimens in clean orthopaedic surgery (primary arthroplasty) for 109 hospitals and trusts across the UK were sought by searching each trust and hospital’s website (intranet webpages), and by using the MicroGuide app. The mean cost of each antibiotic regimen was calculated using price data from the British National Formulary (BNF). Regimens were then compared to the 2018 Philadelphia Consensus Guidance, to evaluate adherence to international guidance. Results. The primary choice and dosing of the prophylactic antimicrobial regimens varied widely. The two most used regimens were combined teicoplanin and gentamicin, and cefuroxime followed by two or three doses of cefuroxime eight-hourly, recommended by 24 centres (22.02%) each. The alternative choice and dosing of the prophylactic antimicrobial regimen also varied widely across the 83 centres with data available. Prophylaxis regimens across some centres fail to cover the likeliest causes of surgical site infection (SSI). Five centres (4.59%) recommend co-amoxiclav, which confers no Staphylococcus coverage, while 33 centres (30.28%) recommend cefuroxime, which confers no Enterococcus coverage. Limited adherence to 2018 Philadelphia Consensus Guidance was observed, with 67 centres (61.50%) not including a cephalosporin in their guidance. Conclusion. This analysis of guidance on antimicrobial prophylaxis in primary arthroplasty across 109 hospitals and trusts in the UK has identified widespread variation in primary and alternative antimicrobial regimens currently recommended. Cite this article: Bone Jt Open 2023;4(10):742–749


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1073 - 1080
1 Sep 2022
Winstanley RJH Hadfield JN Walker R Bretherton CP Ashwood N Allison K Trompeter A Eardley WGP

Aims. The Open-Fracture Patient Evaluation Nationwide (OPEN) study was performed to provide clarity in open fracture management previously skewed by small, specialist centre studies and large, unfocused registry investigations. We report the current management metrics of open fractures across the UK. Method. Patients admitted to hospital with an open fracture (excluding phalanges or isolated hand injuries) between 1 June 2021 and 30 September 2021 were included. Institutional information governance approval was obtained at the lead site and all data entered using Research Electronic Data Capture software. All domains of the British Orthopaedic Association Standard for Open Fracture Management were recorded. Results. Across 51 centres, 1,175 patients were analyzed. Antibiotics were given to 754 (69.0%) in the emergency department, 240 (22.0%) pre-hospital, and 99 (9.1%) as inpatients. Wounds were photographed in 848 (72.7%) cases. Median time to first surgery was 16 hrs 14 mins (interquartile range (IQR) 8 hrs 29 mins to 23 hrs 19 mins). Complex injuries were operated on sooner (median 12 hrs 51 mins (IQR 4 hrs 36 mins to 21 hrs 14 mins)). Of initial procedures, 1,053 (90.3%) occurred between 8am and 8pm. A consultant orthopaedic surgeon was present at 1,039 (89.2%) first procedures. In orthoplastic centres, a consultant plastic surgeon was present at 465 (45.1%) first procedures. Overall, 706 (60.8%) patients required a single operation. At primary debridement, 798 (65.0%) fractures were definitively fixed, while 734 (59.8%) fractures had fixation and coverage in one operation through direct closure or soft-tissue coverage. Negative pressure wound therapy was used in 235 (67.7%) staged procedures. Following wound closure or soft-tissue cover, 509 (47.0%) patients received antibiotics for a median of three days (IQR 1 to 7). Conclusion. OPEN provides an insight into care across the UK and different levels of hospital for open fractures. Patients are predominantly operated on promptly, in working hours, and at specialist centres. Areas for improvement include combined patient review and follow-up, scheduled operating, earlier definitive soft-tissue cover, and more robust antibiotic husbandry. Cite this article: Bone Joint J 2022;104-B(9):1073–1080


Bone & Joint 360
Vol. 12, Issue 4 | Pages 32 - 35
1 Aug 2023

The August 2023 Trauma Roundup. 360. looks at: A comparison of functional cast and volar-flexion ulnar deviation for dorsally displaced distal radius fractures; Give your stable ankle fractures some AIR!; Early stabilization of rib fractures – an effective thing to do?; Locked plating versus nailing for proximal tibia fractures: A multicentre randomized controlled trial; Time to flap coverage in open tibia fractures; Does tranexamic acid affect the incidence of heterotropic ossification around the elbow?; High BMI – good or bad in surgical fixation of hip fractures?


Bone & Joint 360
Vol. 12, Issue 2 | Pages 34 - 36
1 Apr 2023

The April 2023 Trauma Roundup. 360. looks at: Displaced femoral neck fractures in patients aged 55 to 70 years: internal fixation or total hip arthroplasty?; Tibial plateau fractures: continuous passive motion approves range of motion; Lisfranc fractures: to fuse or not to fuse, that is the question; Is hardware removal after clavicle fracture plate fixation beneficial?; Fixation to coverage in Grade IIIB open fractures – what’s the time window?; Nonoperative versus locking plate fixation in the proximal humerus; Retrograde knee nailing or lateral plate for distal femur fractures?


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1662 - 1668
1 Nov 2021
Bhanushali A Chimutengwende-Gordon M Beck M Callary SA Costi K Howie DW Solomon LB

Aims. The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. Methods. Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable. Results. Analysis of supine and standing radiographs resulted in significant variation for measurements of PT (p < 0.001) and AC (p = 0.005). The variation in PT correlated with the variation in AC in a limited number of patients (R. 2. = 0.378; p = 0.012). Conclusion. The significant variation in PT and AC between supine and standing radiographs suggests that it may benefit surgeons to have both radiographs when planning surgical correction of hip dysplasia. We also recommend using PACS-derived measurements of AI and SA due to the poor interobserver error on Hip2Norm. Cite this article: Bone Joint J 2021;103-B(11):1662–1668