Intervertebral disc (IVD) degeneration is inadequately understood due to the lack of in vitro systems that fully mimic the mechanical and biological complexity of this organ. We have recently made an advancement by developing a
Introduction. Supraspinatus tears comprise most rotator cuff injuries, the leading cause of shoulder pain and an increasing problem with ageing populations. Surgical repair of considerable or persistent damages is customary, although not invariably successful. Tissue engineering presents a promising alternative to generate functional tissue constructs with improved healing capacities. This study explores tendon tissue constructs’ culture in a platform providing physiological mechanical stimulation and reports on the effect of different loading regimes on the viability of human tendon cells. Method. Porcine decellularized tendon scaffolds were fixed into flexible, self-contained
The success of cementless orthopaedic implants relies on bony ingrowth and active bone remodelling. Much research effort is invested to develop implants with controllable surface roughness and internal porous architectures that encourage these biological processes. Evaluation of these implants requires long-term and costly animal studies, which do not always yield the desired outcome requiring iteration. The aim of our study is to develop a cost-effective method to prescreen design parameters prior to animal trials to streamline implant development and reduce live animal testing burden. Ex vivo porcine cancellous bone cylinders (n=6, Ø20×12mm) were extracted from porcine knee joints with a computer-numerically-controlled milling machine under sterile conditions within 4 hours of animal sacrifice. The bone discs were implanted with Ø6×12mm additive manufactured porous titanium implants and were then cultured for 21days. Half underwent static culture in medium (DMEM, 10% FBS, 1% antibiotics) at 37°C and 5% CO. 2. The rest were cultured in novel high-throughput stacked configuration in a
Introduction Tissue engineering aims to produce a cellular structure in an extracellular matrix, which when implanted heals tissue defects. To tissue-engineer bone suitable cells need to be grown on a scaffold. In this study we grew human marrow cells as they can differentiate into osteoblasts, on porous hydroxyapatite (HA) scaffolds, as this is osteoconductive, allows cell penetration and in growth of capillaries after implantation. Increased extravascular perfusion through bone increases new bone formation. So we reproduced these physiological conditions in our novel
Joint pain, as a consequence of cartilage degeneration or trauma results in severe pain or disability for millions of individuals worldwide. However, the potential for cartilage to regenerate is limited and there is an absence of clinically viable cartilage formation regimes. Cartilage is composed of only one cell type, is avascular and has a relatively simple composition and structure, thus cartilage tissue engineering has tremendous potential. Therefore, to address this clinical need, we have adopted a tissue engineering approach to the generation of cartilage ex vivo from mesenchymal cell populations encapsulated in polysaccharide templates form alginate and chitosan that favours chondrogenesis, and cultured within perfused or rotating
Introduction. The combined incubation of a composite scaffold with bone marrow stromal cells in a perfusion
Bioreactors have been used in articular cartilage tissue engineering (AC-TE) to apply different mechanical stimuli in an attempt to better mimic the native AC microenvironment. However, these systems are often highly complex, costly and not very versatile. In this work, we propose a simple and customizable perfusion
Due to its avascular nature, articular cartilage exhibits a very limited capacity to regenerate and to repair. Although much of the engineered cartilage grafts so far proposed have successfully shown to mimic the morphological and biochemical appearance of hyaline cartilage, they are generally mechanically inferior to the natural tissue. 1. In this study a new
Introduction: Recently, co-transplantion of mesenchy-mal stem cells (MSCs) with hematopoietic stem cells (HSCs) has been shown to alleviate complications such as GVHD and speeding recovery of HSCs. This in vivo finding suggests that coculture of MSCs and HSCs may enhance their growth potentials in vitro. As the large-scale expansion of HSCs has been achieved by NASA’s suspension culture system, we further examined the effects of this suspension culture system (rotary bio-reactor) on MSCs’ proliferation and differentiation potentials in vitro. Methods: Mononuclear cell fractions (MNCs) of human bone marrow aspirates (n=6, ages 46–81) were collected by density gradient centrifugation. The cells were inoculated into
Mechanical loading regulates the metabolism of chondrocytes in cartilage1. Nowadays, studies exploring the in vitro response of cartilage towards loading often rely on
Background. Recent advances in materials and manufacturing processes for arthroplasty have allowed fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies is hindered by the cost and complications of animal studies, particularly during early iterations in development process. To address this problem, we have constructed and validated an ex-vivo bone
Introduction: The treatment of bone defects that occurs following fractures, the excision of bone tumours and at revision arthroplasty surgery, often involves the use of either autologous or allogenous bone grafts. However, both grafts have limitations. The aim of tissue engineering is to produce cells within an extracellular matrix that resembles tissue, which can be implanted into a patient to heal a tissue defect. The potential to engineer bone tissue grafts from patients’ autologous cells would improve the treatment of bone defects. Bone marrow contains cells, known as mesenchymal stem cells (MSCs), which have the ability to differentiate into osteoblasts. To create a 3-dimensional structure necessary for the reconstruction of tissue, cells need to be grown on a scaffold, for which hydroxyapatite (HA) was used, as it is osteoconductive. In living bone, increased extravascular perfusion increases new bone formation. Thus, these physiological conditions were reproduced in our novel
Bioreactors used in tissue engineering are mostly batch-fed with media added and removed periodically. Continuous flow
Short Summary. The present study demonstrated the feasibility of culturing a large number of standardised granular MSC-containing constructs in a packed bed/column
Introduction: Due to a lack of techniques there is only some data of testing mechanical influence on chondroc-tyes grown in 3-D tissue-culture over several months. The authors developed therfore a new perfusion-chamber to study these mechanical factors in in-vitro tissue culture. Methods: A pneumatic computer-controlled
Using the trabecular bone
Background. For bone grafting procedures, the use of autologous bone is considered the gold standard, as it is has a better healing capacity compared to other alternatives as allograft and synthetic bone substitutes. However, as there are several drawbacks related to autografting (infection, nerve- or vascular damage, chronic pain problems, abdominal herniation), there has been a targeted effort to improve the healing capacities of synthetic bone substitutes. Aim. To evaluate the performance of a carbonated osteoionductive hydroxyapatite (CHA) scaffold of clinical relevant size (Ø=15mm, H=50mm) in a sheep model of multi level posterolateral intertransverse lumbar spine fusion after activation with autologous bone marrow nuclear cells (BMNC) in a flow perfusion
Induced membrane technique is a relatively new technique in the reconstruction of large bone defects. It involves the implantation of polymethylmethacrylate (PMMA) cement in the bone defects to induce the formation of membranes after radical debridement and reconstruction of bone defects using an autologous cancellous bone graft in a span of four to eight weeks. The purpose of this study was to explore the clinical outcomes of the induced membrane technique for the treatment of post-traumatic osteomyelitis in 32 patients. A total of 32 cases of post-traumatic osteomyelitis were admitted to our department between August 2011 and October 2012. This retrospective study included 22 men and ten women, with a mean age of 40 years (19 to 70). Within this group there were 20 tibias and 12 femurs with a mean defect of 5 cm (1.5 to 12.5). Antibiotic-loaded PMMA cement was inserted into the defects after radical debridement. After approximately eight weeks, the defects were implanted with bone graft.Objectives
Methods
One of the mechanisms which controls bone growth, repair remodeling and absorption is mechanical loading. There exists no long-term in vitro model to study bone cells together with their matrix, nor a model that can apply quantitative mechanical forces of physiological amplitudes and frequencies. The analysis of the mechanical properties of bone (Young’s modulus and visco-elastic moduli) on small pieces of bone is also difficult with present devices. We have built a device that can maintain full viability and physiological response of bone for a period of several weeks and integrates all three functions. 10mm diameter bone cores 5 mm thick were obtained from the trabecular bone of the distal ulna of a 24 months old cow by precision cutting with diamond saws and keyhole cutters (our pattern) in sterile 7–10°C phosphate buffered saline (PBS) and cultured in a variation of DMEM containing fructose HI GEM.
We gratefully acknowledge support by the German Arthrose Foundation (DAH) and the AO in Davos, CH.