Receive monthly Table of Contents alerts from Bone & Joint Research
Comprehensive article alerts can be set up and managed through your account settings
View my account settings
Nonunion occurs when a fracture fails to heal permanently, often necessitating surgical intervention to stimulate the bone healing response. Current animal models of long-bone nonunion do not adequately replicate human pathological conditions. This study was intended as a preliminary investigation of a novel rat nonunion model using a two-stage surgical intervention, and to evaluate the efficacy of a selective prostaglandin E2 receptor 4 agonist (AKDS001) as a novel nonunion therapeutic agent compared with existing treatments. Initially, Sprague-Dawley rats underwent intramedullary Kirschner wire (K-wire) fixation of a femoral fracture with the interposition of a 2 mm-thick silicon disc. After three weeks, the silicon disc was removed, and the intramedullary K-wire was replaced with plate fixation while maintaining the 2 mm defect. Contrary to the control group (1) that received no treatment, the following therapeutic interventions were performed at injury sites after freshening: (2) freshening group: no grafting; (3) iliac bone (IB) group: IB grafting; (4) AKDS group: AKDS001-loaded microspheres (MS) combined with IB (0.75 mg/ml); and (5) bone morphogenetic protein (BMP) group: grafting of a BMP-2-loaded collagen sponge (10 μg; 0.10 mg/ml). After six weeks, micro-CT (μCT) and histological analysis was performed.Aims
Methods
The diagnosis of periprosthetic joint infection (PJI) remains a challenge, as no single diagnostic test shows high diagnostic accuracy. Recently, the measurement of synovial biomarkers has shown promising results. The aim of this study was to present a novel multiplex micro-enzyme-linked immunosorbent assay (ELISA) method for the rapid and simultaneous measurement of alpha-defensin, interleukin (IL)-6, and calprotectin developed in a model buffer system and human spiked synovial fluid. A microfluidics- and chemiluminescence-based multiplex micro-ELISA point-of-care testing system was employed for the rapid and simultaneous measurement of alpha-defensin, calprotectin, and IL-6 developed in a model buffer system and spiked human synovial fluid. Cut-off values of 1.56 µg/ml for alpha-defensin, 50 µg/ml for calprotectin, and 0.031 µg/ml for IL-6 were extracted from the literature as optimal cut-off values for the diagnosis of PJI, and were used for comparison.Aims
Methods